You are on page 1of 1

Hydrostatic Pressure Report in bar

Machine Name Hydro static pressure tester (104-D)


Minimum Pressure 49.08
Date and Time 26/11/2023 09:27:00 Selection option 1
Maximum Pressure 50.40
Date and Time 26/11/2023 09:26:00

BASIC INFORMATION

Customer Name DANCO CAPITAL LIMITED Job no.


Customer Code 1 Location of test IN-HOUSE
Test Sr No. 719 Date of sampling 26/11/2023
Current Date 26/11/2023 Sampling Method RANDOM
Test Standard ISO 1167 Current Time 8:58:00 AM
Product Name PPR Test ID 15874
Pipe Diameter 32 Product Code 22615
Test Bath No 3 Pipe Wall Thick 4.4

TEST RESULTS

set_hours 1 set_scan_time 100


set_prs_high 50.20 set_prs_low 50.00
set_diff_high 0.01 set_diff_low 0.01
set_prs_burst 2 set_test_type 0
set_perc_high 100 set_perc_low 100

Remarks PASS @ 50.10

Q.C. IN CHARGE - EUGENE ROY

You might also like