NATIONAL INSTITUTE OF TECHNOLOGY ROURKELA

Department of Electrical Engineering


Mid-Semester Examination, 2019 - 2020 (Spring)
B.Tech. 6th Semester

Subject Name: Power System Operation and Control


Subject Code: EE3100

INSTITUTE OF
Number of Pages: 2
TECHNOLOGY Full Marks: 30 Duration: 2 Hours
Figures at the right hand margin indicate marks. All parts of a question should be answered at one place.

ROURKELAAnswers should All symbols carry usual meaning. Assume standard value for any missing data.
be brief and to the point. Irrelevant answer may lead to negative marking.

Q1. (a) Write the expressions of Nij and Jij used in NRLF. 2

(b) With appropriate assumptions, show that Nij and Jij are nearly equal to zero. 3

Q2. Single-line diagram of a four bus power system and its Y bus matrix are shown below. Fill the 1-3 element 3
of Y matrix.

 
 −j48.06 0 ? 0
 
1 2  

 0 −j37.70 0 j38.83
ȳ T ȳ T
 
1 T1 T2 2
 
¯
49.02∠95o 0 −j90.00 j40.00
ᾱ : 1 β : 1  
ȳ line
 
 
0 j38.83 j40.00 −j80.00
3 4

Y bus matrix in per-unit

Q3. Single-line diagram of a three-bus power system and its Y bus matrix are given next. Bus 1 and 3 are 4
voltage controlled bus. Line impedances and specified voltage are marked in per-unit on a 100 MVA base.
Generation at bus 3 and load at bus 2 are as given. Using one iteration of Gauss-Seidel method, determine
V̄3 . Take bus 1 as reference. Do not use acceleration coefficient.

300 MW

¯ o
V3 = 1.03
V 1 = 1.025∠0

1 3
j0.05

 
−j60.00 j40.00 j20.00
 
 
j0.025 j0.025
Y =
 j40.00 −j80.00  pu
j40.00
 
 
j20.00 j40.00 −j60.00
2

400 MW + j200 MVAR

Continued on the next page


EE3100 Mid Semester Examination Page 2 of 2

Q4. A three-phase load (S̄3φ ) at bus j is supplied from a generator at bus i through two regulating transformers 4
(T1 , T2 ). Total impedance of the two transformers referred to the H.V. side is z̄. If P1φ + jQ1φ is the per
phase power drawn at bus j, assuming the product of off-nominal tap ratios α and β is unity, and
neglecting the phase shift between V̄i0 and V̄j0 as an approximation, prove that
  12
 Vj /Vi 
α= rP1φ +xQ1φ
1 − 
Vi Vj

i j
T1 T2

z̄ = r + jx

1 : α β : 1
′ ′
¯ ¯ ¯ ¯ ¯
Vi V V Vj S 3ϕ = P3ϕ + jQ3ϕ
i j

Q5. Single-line diagram of a three-bus power system and its Z bus matrix are shown below. One of the circuits 4
of line 1-2 is removed for maintenance. Form Z bus matrix of the modified system using Z-bus building
algorithm.

1 2
 
(1) 3
x̄ = 0.04 pu
line j0.0198 j0.0195 j0.0192
 
 
Z=
j0.0195 j0.0390  pu
j0.0384
 
(2)
x̄ = 0.04 pu xload = 1.6 pu
 
line
j0.0192 j0.0384 j0.0625
xg = 0.02 pu
xt = 0.025 pu

Q6. Single-line diagram of a two-bus power system and its positive sequence impedance bus matrix (Z1 ) are
given below. Sequence reactance of each circuit of the transmission line are: X1 = X2 = 0.5 pu, X0 = 1.5
pu. Reactance of T1 and T2 is 0.08 pu each. Positive, negative and zero sequence reactance of G1 and
G2 are: X1 = X2 = 0.02 pu, X0 = 0.05 pu, Xn = 0.02 pu. A line-to-ground fault with impedance j0.01
pu occurs on one of circuits of line 1-2 at a distance 60% from bus 1, as shown in the figure (marked as
pseudo-bus 3). Before the occurrence of fault, system was unloaded, and voltage at all buses were 1.02 pu.

1 2  
j0.0778 j0.0222 j0.0444
G1 T1 T2 G2  
 
j0.0222 j0.0778 j0.0556
 
 
3  
j0.0444 j0.0556 j0.1711

Positive sequence impedance


matrix in per-unit

(a) Form zero sequence impedance matrix. 4


(b) Compute fault current in phase domain. 2
(c) Compute three phase current injected by generator G1 . 4

End of question paper. ALL THE BEST.