You are on page 1of 8

Issue date: 2024-03-20 16:33:58

TM
SemiSel Prepared by: Vinh
Calculation Report Application:
Customer:
File name: project 1

Description:

1. Circuit Parameter 2
1.1 Nominal Load 2
1.2 Extended Overload Configuration 2
2. Product 3
3. Cooling 5
3.1 Product Arrangement 5
3.2 Fixed Heatsink Temperature 5
4. Calculation Results 6
4.1 Nominal Load 6
4.2 Overload 7
IMPORTANT INFORMATION AND WARNINGS 8

© by Semikron Danfoss / 2024-03-20 / SemiSel Report (SemiSel V5 - B 20240215.4 - Db 20240318152859) Page 1/8
1. Circuit Parameter
AC/DC: B2U

1.1 Nominal Load

Input voltage (Vin) Input frequency (fin)


220 Vrms 50 Hz
Output current (Iout
Output current RMS (Iout rms)
average)
20.1 Arms
20 A

Current form factor (Fi) Additional losses per heatsink


(P+HS)
1.42 0W

1.2 Extended Overload Configuration


Number of Cycles to be calculated: 1

30

28

26

24

22

20
30

28

26

24

22

20
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

© by Semikron Danfoss / 2024-03-20 / SemiSel Report (SemiSel V5 - B 20240215.4 - Db 20240318152859) Page 2/8
2. Product
SKB 30/08 A1

Voltage class: 800 V


Current class: 30 A
Technology: 1 and 3 phase
Case: G12
Main terminals: Screw
Baseplate: Yes
Switches: B2
Product status: In production

Typical Values used for calculation.

D1 D2
Iref 30 A 30 A
Vref 0V 0V
Tj op 135 °C 135 °C
Tj max 150 °C 150 °C
Vf @ 25°C, Iref 1.18 V 1.18 V
Vf @ Tjop, Iref 1.11 V 1.11 V
RgOn

RgOff

Eon
Eoff

© by Semikron Danfoss / 2024-03-20 / SemiSel Report (SemiSel V5 - B 20240215.4 - Db 20240318152859) Page 3/8
D1 D2
Rth(j-c) 4.2 K/W 4.2 K/W
Rth(c-s)

Rth(c-s) per module: 0.1 K/W


(Including thermal coupling, heatsink temperature measured underneath module)

© by Semikron Danfoss / 2024-03-20 / SemiSel Report (SemiSel V5 - B 20240215.4 - Db 20240318152859) Page 4/8
3. Cooling

3.1 Product Arrangement


Phase legs per heatsink: 2
Parallel switches: 1
Number of heatsinks: 1
Products per heatsink: 1
Total number of products: 1

3.2 Fixed Heatsink Temperature

Heatsink temperature: 50 °C

© by Semikron Danfoss / 2024-03-20 / SemiSel Report (SemiSel V5 - B 20240215.4 - Db 20240318152859) Page 5/8
4. Calculation Results

Critical temperature is not exceeded.

4.1 Nominal Load


Efficiency: 0%
Ciruit losses: 40.31 W
Losses per heatsink: 40.31 W

Single output period results for D1

Single output period results for D2

© by Semikron Danfoss / 2024-03-20 / SemiSel Report (SemiSel V5 - B 20240215.4 - Db 20240318152859) Page 6/8
4.2 Overload
Temperature maxima

Loadcycle results for D1

Loadcycle results for D2

© by Semikron Danfoss / 2024-03-20 / SemiSel Report (SemiSel V5 - B 20240215.4 - Db 20240318152859) Page 7/8
IMPORTANT INFORMATION AND WARNINGS
The information provided in this document may not be considered as guarantee or assurance of product
c harac teris tic s ("Beschaffenheitsgarantie"). S E MIK R O N does not assume any warranty or liability with
respect to the accuracy, correctness, completeness and/or use of any information in this document. This
document describes only the usual characteristics of products to be expected in typical applications, which
may still vary depending on the specific application. Therefore, products must be tested for the respective
application in advance. Application adjustments may be necessary. The user of S E MIK R O N products is
responsible for the safety of their applications embedding S E MIK R O N products and must take adequate
safety measures to prevent the applications from causing a physical injury, fire or other problem if any of
S E MIK R O N products become faulty. The user is responsible to make sure that the application design is
compliant with all applicable laws, regulations and standards. Except as otherwise explicitly approved by
S E MIK R O N in a written document signed by authorized representatives of S E MIK R O N, S E MIK R O N
products may not be used in any applications where a failure of the product or any consequences of the use
thereof can reasonably be expected to result in personal injury.

S E MIK R O N INT E R NAT IO NAL GmbH


Sigmundstrasse 200, 90431 Nuremberg, Germany
Tel: +49 911 6559 6663, Fax: +49 911 6559
sales.skd@semikron-danfoss.com, www.semikron-danfoss.com

© by Semikron Danfoss / 2024-03-20 / SemiSel Report (SemiSel V5 - B 20240215.4 - Db 20240318152859) Page 8/8