END TO END DESIGN PARAMETERS

NUMBERS OF FIBERS 12 DISTANCE IN FEET 7.871


TYPE OF CABLE ‐ SINGLEMODE (0.35DB / KM)
TYPE OF CONNECTORS AT C.O. : PC / 60
TYPE OF CONNECTORS AT R.T. : PC / 60

CABLE LOSSES THRU PATCHCORDS 1310 NM


1310 NM KM X .35 DB / KM 0,84 DB
1550 NM KM X .25 DB / KM Insert correct # bellow ‐‐‐‐‐
C.O. ADC FRAME CONN. X . 5DB / CONN 1 0,50
VAULT SPLICE SPL. X .1DB / SPL 0,00
CABLE SPLICES SPL. X .1DB / SPL 8 0,80
PIGTAIL SPLICE (RT) SPL. X .1DB / SPL 0,00
SPLITTER INSERTION LOSS QTY X .6DB / SPT 3 1,80
REMOTE CONNECTORS IN SPL. X .5DB / SPL 0,00
SPLICE CHAMBERS

MAX. CALCULATED LOSS THRU PATCHCORD 3,94 DB

MAX. CALCULATED LOSS W / O PATCHCORD 2,14 DB

MAX. CHROMATIC DISPERSION NOT REQ'D AT THIS TI

For current fiber (SR) and splices


1550 NM
‐‐‐‐‐
0,60 DB
0,50
0,00
0,80
0,00
1,80
0,00

3,70 DB

1,90 DB