You are on page 1of 2

No.

Indicator/Button Description Remarks


G5500 V7 Server Quick Start Guide
2 Health status ⚫ Off: The device is powered off or is faulty. For details about
indicator how to handle
Document Issue: 02 (2023-10-10) BOM: 3150Y049 (2/3) ⚫ Blinking red at 1 Hz: A major alarm has alarms, see the
been generated on the system. FusionServer
xFusion Digital Technologies Co., Ltd.
⚫ Blinking red at 5 Hz: A critical alarm has G5500 Server
iBMC Alarm
been generated on the system.
Copyrights © xFusion Digital Technologies Co., Ltd. 2023. All rights reserved. Handling.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of xFusion Digital ⚫
Technologies Co., Ltd. Steady green: The device is operating
and other xFusion trademarks are trademarks of xFusion Digital Technologies Co., Ltd. properly.
All other trademarks or trade names mentioned in this document are the property of their respective holders.
In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description and easy understanding,
3 Power Power indicator: None
which does not mean that "xFusion" may have any other meaning. Any "xFusion" mentioned or described hereof may not be understood as button/indicator ⚫
any meaning other than "xFusion Digital Technologies Co., Ltd.", and xFusion Digital Technologies Co., Ltd. shall not bear any liability 1 UID button/indicator 2 Health status indicator Off: The device is not powered on.
resulting from the use of "xFusion".
The purchased products, services, or features are stipulated by the contract made between xFusion Digital Technologies Co., Ltd and the 3 Power button/indicator 4 Fault diagnosis LED ⚫ Steady green: The device is powered on.
customer. All or part of the products, services, or features described in this document may not be within the purchase scope or the usage 5 FlexIO card 1 presence indicator 6 FlexIO card 3 presence indicator ⚫
scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" Blinking yellow: The iBMC is starting. The
without warranties, guarantees or representations of any kind, either express or implied. 7 iBMC direct connect management port 8 USB 3.0 ports
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to indicator power button is locked and cannot be
ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any
kind, express or implied. 9 iBMC direct connect management port 10 VGA port pressed. The iBMC is started in about 1
xFusion places export control obligations above its commercial interests and refuses to sell or export tangible or intangible products,
technologies, and services for end-users or end-uses prohibited by relevant export control laws and regulations.
11 Slide-out label plate (with an SN label) 12 Drive minute, and then the power indicator is
steady yellow.
1 Introduction ⚫ Steady yellow: The device is standby.
The FusionServer G5500 V7 server (G5500 V7 for short) is a GPU computing server (4U high) that Power button:
is optimized in HPC as well as data training and inference for deep learning. It fits into scenarios ⚫ When the device is powered on, you can
such as AI, HPC, cloud computing, and big data analysis. It supports multiple types of press this button to gracefully shut down
heterogeneous processors and applies to both enterprise and public cloud deployments.
The following table lists the G5500 V7 technical specifications. For details, see the FusionServer the OS.
G5500 V7 Server User Guide. NOTE
Item Specifications For different OSs, you may need to shut
down the OS as prompted.
⚫ When the device is powered on, you can
Dimensions (H x W x D) 175 mm x 447 mm x 898 mm (6.89 in. x 17.60 in. x 35.35 in.)
hold down this button for 6 seconds to
⚫ Operating temperature: 5°C to 35°C (41°F to 95°F) (ASHARE forcibly power off the device.
Classes A1 and A2 compliant) ⚫

When the power indicator is steady yellow,
Storage temperature (within three months): –30°C to +60°C (–
22°F to +140°F) you can press this button to power on the
1 Slot 1 (PCIe 5.0 x16) 2 Slot 3 (PCIe 5.0 x16)
⚫ Storage temperature (within six months): –15°C to +45°C (5°F to device.
Temperature 3 Slot 5 (PCIe 5.0 x16) 4 Slot 7 (PCIe 5.0 x16)
113°F)
5 Slot 9 (PCIe 5.0 x16) 6 Slot 10 (PCIe 5.0 x16) 4 Fault diagnosis ⚫ ---: The device is operating properly. For details about
⚫ Storage temperature (within one year): –10°C to +35°C (14°F to LED error codes, see
7 Slot 12 (PCIe 5.0 x16) 8 Slot 14 (PCIe 5.0 x16) ⚫ Error code: A component is faulty.
95°F)
9 Slot 16 (PCIe 5.0 x16) 10 PSU indicator the
⚫ Maximum temperature change rate: 20°C (36°F) per hour and FusionServer
11 PSU 1 12 Socket for PSU 1
5°C (9°F) per 15 minutes G5500 Server
13 PSU 2 14 Socket for PSU 2
⚫ Operating humidity: 8% to 90% iBMC Alarm
15 PSU 3 16 Socket for PSU 3 Handling
⚫ Storage humidity (within three months): 8% to 85% 17 PSU 4 18 Socket for PSU 4
Relative humidity (non- 5/6 FlexIO card None
⚫ Storage humidity (within six months): 8% to 80% 19 FlexIO card 3 20 Slot 21 (PCIe 5.0 x16) presence
Indicates whether the FlexIO card is
condensing)
⚫ Storage humidity (within one year): 20% to 75% 21 FlexIO card 2 22 Slot 20 (PCIe 5.0 x16) indicator detected.
23 FlexIO card 1 24 Slot 19 (PCIe 5.0 x16)
⚫ Maximum humidity change rate: 20% per hour ⚫ Off: The FlexIO card is not detected.
25 UID indicator 26 USB 3.0 ports
⚫ Blinking green at 0.5 Hz: The FlexIO card
⚫ ≤ 3050 m (10,006.56 ft) 27 VGA port 28 BMC card
When the server configuration complies with ASHRAE Classes 29 Serial port indicator (reserved) 30 Connection status indicator for the is detected but is not powered on.
A1 and A2 and the altitude is above 900 m (2952.76 ft), the management network port ⚫ Blinking green at 2 Hz: The FlexIO card is
Altitude 31 Data transmission status indicator for 32 Management network port
highest operating temperature decreases by 1°C (1.8°F) for detected and has just been inserted.
every increase of 300 m (984.24 ft) the management network port
33 Serial port 34 Slot 18 (PCIe 5.0 x16) ⚫ Steady green: The FlexIO card is detected
⚫ HDDs cannot be used at an altitude of over 3050 m (10,006.56 ft).
and the power supply is normal.
7 iBMC direct Indicates the status when the iBMC direct None
2 Front and Rear Panels 3 Indicators and Buttons connect
management
connect management port connects to a
terminal (local PC or Android mobile phone):
Indicators and buttons on the front panel port indicator ⚫ Off: No terminal is connected.
No. Indicator/Button Description Remarks ⚫ Blinking green at short intervals for 3
1 UID The UID button/indicator helps identify and None seconds and then off: The port is disabled.
button/indicator locate a device. ⚫ Steady green: The terminal is connected.
UID indicator:
Indicates the status when the iBMC direct
⚫ Off: The device is not being located.
connect management port connects to a
⚫ Blinking or steady blue: The device is USB device:
being located. ⚫ Blinking red at long intervals: The job fails
UID button: or an error is reported when the job is
⚫ You can control the UID indicator status
complete.
by pressing the UID button or using the ⚫ Blinking green at short intervals: The job is
iBMC. being executed.
⚫ You can press this button to turn on or off ⚫ Blinking green at short intervals for 3
the UID indicator. seconds and then off: The port is disabled.
⚫ You can press and hold down this button ⚫ Steady green: The server configuration file
for 4 to 6 seconds to reset the iBMC. is being copied from the USB device or

1 2 3
No. Indicator/Button Description Remarks ⚫ At least four persons are required to move the chassis. When moving a chassis, keep your back  Power on the server using the Remote Virtual Console.
straight and move smoothly to avoid any injury. Log in to the Remote Virtual Console. On the KVM screen, click or on the
the job is successfully completed. toolbar, select Power On, and click OK.
Indicators on the rear panel ⚫ Do not use mounting ears as the holding points when moving the server. Otherwise, the server
No. Indicator Description Remarks may be damaged or slipped. 7 Error Codes
10 PSU indicator Replace the PSU 1. Install the server. Error Code Fault Description Remarks
⚫ Off: No power is supplied.
if the indicator is (1) Place the G5500 V7 server on the guide rails and push it into the cabinet.
⚫ Blinking green at 1 Hz: in any of the (2) Align the mounting ears on both sides of the G5500 V7 server with the mounting bars
--- The server is operating normally. -
 The input is normal, and the server
following states: of the cabinet, and tighten the captive screws on the mounting ears to secure the C0X CPU X is abnormal or faulty. X indicates the CPU number.
is standby. G5500 V7 server.
 The input is overvoltage or ⚫ Blinking green XXX indicates the DIMM
XXX DIMM XXX is abnormal or faulty.
undervoltage. at 1 Hz after number.
 The PSU is in deep hibernation The air inlet temperature is out of the
the server is A00 -
mode. operating temperature range of the server.
⚫ Blinking green at 4 Hz: The firmware is powered on The temperature of CPU X exceeds its
A0X X indicates the CPU number.
⚫ Steady orange normal range.
being upgraded online.
⚫ Steady green: The power input and output
P0X PSU X is abnormal or faulty. X indicates the PSU number.
X indicates the fan module
are normal. F0X Fan module X is abnormal or faulty.
number.
⚫ Steady orange: The power input is normal The power supply to the mainboard is
b01 -
but there is no power output. abnormal.
NOTE The RAID controller card is abnormal or
b02 -
The possible causes of no power output are faulty.
as follows: The cable is not securely or correctly
L01 -
⚫ Power supply overtemperature protection connected.
⚫ Power output overcurrent or short-circuit E01 The CMOS battery is abnormal. -
⚫ Output overvoltage XX indicates the drive
HXX The drive in slot XX is abnormal or faulty.
number.
⚫ Short-circuit protection
⚫ In this table, X is an integer as well as an Arabic numeral.
⚫ Device failure (excluding failure of all
⚫ For more information about error codes, see the FusionServer G5500 Server iBMC Alarm
devices) 2. Connect cables to service and management network ports.
25 UID indicator The UID indicator helps identify and locate a Handling.
None
8 Follow-up
device.
⚫ Off: The device is not being located.
After the G5500 V7 server has been installed and powered on, complete follow-up tasks such as
⚫ Blinking or steady blue: The device is being
configuring the server by referring to the FusionServer G5500 V7 Server User Guide.
located. Obtain the document from https://www.xfusion.com/en.
NOTE
You can control the UID indicator status by 3. Connect the power cables. Appendix: Hazardous Substance Statement for Electronic and
pressing the UID button or using the iBMC. Electrical Products
30 Connection ⚫ Off: The network port is not connected. None
Hazardous Substances
status indicator Component
⚫ Steady green: The network port is Cd Pb Hg Cr (VI) PBBs PBDEs
for the
management connected properly. PCBA ○ × ○ ○ ○ ○
network port Cables ○ × ○ ○ ○ ○
31 Data ⚫ Off: No data is being transmitted. None Metal Parts ○ × ○ ○ ○ ○
transmission ⚫ Polymeric Parts ○ ○ ○ ○ ○ ○
status indicator Blinking yellow: Data is being transmitted.
for the
Batteries ○ × ○ ○ ○ ○
management This table is prepared in accordance with the SJ/T 11364.
network port "○" indicates that the content of the hazardous substance contained in all of the homogenous
materials for the component is below the limit specified in GB/T 26572.

4 Tools
"×" indicates that the content of the hazardous substance contained in at least one
homogenous material exceeds the limit specified in GB/T 26572.

6 Power-On
ESD gloves Floating nut mounting bar Phillips screwdriver Ladder

5 Installation The G5500 V7 does not provide a separate ground port. It uses power cables for ground
connection. The equipment is powered by high-voltage power sources. Direct or indirect contact
(especially through damp objects) with high-voltage power sources may result in serious injury or
death.
⚫ Exercise caution when using tools. Power on the G5500 V7 server using any of the following methods:
⚫ ⚫ If the PSUs are properly installed but not powered on, connect the PSUs to the external power
If the installation position of the device is higher than the shoulders of the installation personnel,
supply. The G5500 V7 server is powered on along with the PSUs.
use a ladder or lift to facilitate installation and to prevent the equipment from falling down and
causing personal injury or damage to the equipment. Do not use a ladder if you are alone and ⚫ If the PSUs are properly installed and connected to the external power supply, and the G5500
cannot get assistance. V7 server is standby (the power indicator is steady yellow), power on the server as follows:
 Press the power button on the front panel to power on the server.
 Power on the server using the iBMC WebUI.
Log in to the iBMC WebUI, choose System > Power > Power Control, click Power
⚫ Before touching a device, wear ESD gloves and remove any conductive objects, such as On, and click OK.
watches and jewelry.  Power on the server using the iBMC CLI.
Log in to the iBMC CLI, run the ipmcset -d powerstate -v 1 command, and enter y or Y.

4 5 6

You might also like