Professional Documents
Culture Documents
FusionServer G5500 V7 Server Quick Start Guide 02
FusionServer G5500 V7 Server Quick Start Guide 02
1 2 3
No. Indicator/Button Description Remarks ⚫ At least four persons are required to move the chassis. When moving a chassis, keep your back Power on the server using the Remote Virtual Console.
straight and move smoothly to avoid any injury. Log in to the Remote Virtual Console. On the KVM screen, click or on the
the job is successfully completed. toolbar, select Power On, and click OK.
Indicators on the rear panel ⚫ Do not use mounting ears as the holding points when moving the server. Otherwise, the server
No. Indicator Description Remarks may be damaged or slipped. 7 Error Codes
10 PSU indicator Replace the PSU 1. Install the server. Error Code Fault Description Remarks
⚫ Off: No power is supplied.
if the indicator is (1) Place the G5500 V7 server on the guide rails and push it into the cabinet.
⚫ Blinking green at 1 Hz: in any of the (2) Align the mounting ears on both sides of the G5500 V7 server with the mounting bars
--- The server is operating normally. -
The input is normal, and the server
following states: of the cabinet, and tighten the captive screws on the mounting ears to secure the C0X CPU X is abnormal or faulty. X indicates the CPU number.
is standby. G5500 V7 server.
The input is overvoltage or ⚫ Blinking green XXX indicates the DIMM
XXX DIMM XXX is abnormal or faulty.
undervoltage. at 1 Hz after number.
The PSU is in deep hibernation The air inlet temperature is out of the
the server is A00 -
mode. operating temperature range of the server.
⚫ Blinking green at 4 Hz: The firmware is powered on The temperature of CPU X exceeds its
A0X X indicates the CPU number.
⚫ Steady orange normal range.
being upgraded online.
⚫ Steady green: The power input and output
P0X PSU X is abnormal or faulty. X indicates the PSU number.
X indicates the fan module
are normal. F0X Fan module X is abnormal or faulty.
number.
⚫ Steady orange: The power input is normal The power supply to the mainboard is
b01 -
but there is no power output. abnormal.
NOTE The RAID controller card is abnormal or
b02 -
The possible causes of no power output are faulty.
as follows: The cable is not securely or correctly
L01 -
⚫ Power supply overtemperature protection connected.
⚫ Power output overcurrent or short-circuit E01 The CMOS battery is abnormal. -
⚫ Output overvoltage XX indicates the drive
HXX The drive in slot XX is abnormal or faulty.
number.
⚫ Short-circuit protection
⚫ In this table, X is an integer as well as an Arabic numeral.
⚫ Device failure (excluding failure of all
⚫ For more information about error codes, see the FusionServer G5500 Server iBMC Alarm
devices) 2. Connect cables to service and management network ports.
25 UID indicator The UID indicator helps identify and locate a Handling.
None
8 Follow-up
device.
⚫ Off: The device is not being located.
After the G5500 V7 server has been installed and powered on, complete follow-up tasks such as
⚫ Blinking or steady blue: The device is being
configuring the server by referring to the FusionServer G5500 V7 Server User Guide.
located. Obtain the document from https://www.xfusion.com/en.
NOTE
You can control the UID indicator status by 3. Connect the power cables. Appendix: Hazardous Substance Statement for Electronic and
pressing the UID button or using the iBMC. Electrical Products
30 Connection ⚫ Off: The network port is not connected. None
Hazardous Substances
status indicator Component
⚫ Steady green: The network port is Cd Pb Hg Cr (VI) PBBs PBDEs
for the
management connected properly. PCBA ○ × ○ ○ ○ ○
network port Cables ○ × ○ ○ ○ ○
31 Data ⚫ Off: No data is being transmitted. None Metal Parts ○ × ○ ○ ○ ○
transmission ⚫ Polymeric Parts ○ ○ ○ ○ ○ ○
status indicator Blinking yellow: Data is being transmitted.
for the
Batteries ○ × ○ ○ ○ ○
management This table is prepared in accordance with the SJ/T 11364.
network port "○" indicates that the content of the hazardous substance contained in all of the homogenous
materials for the component is below the limit specified in GB/T 26572.
4 Tools
"×" indicates that the content of the hazardous substance contained in at least one
homogenous material exceeds the limit specified in GB/T 26572.
6 Power-On
ESD gloves Floating nut mounting bar Phillips screwdriver Ladder
5 Installation The G5500 V7 does not provide a separate ground port. It uses power cables for ground
connection. The equipment is powered by high-voltage power sources. Direct or indirect contact
(especially through damp objects) with high-voltage power sources may result in serious injury or
death.
⚫ Exercise caution when using tools. Power on the G5500 V7 server using any of the following methods:
⚫ ⚫ If the PSUs are properly installed but not powered on, connect the PSUs to the external power
If the installation position of the device is higher than the shoulders of the installation personnel,
supply. The G5500 V7 server is powered on along with the PSUs.
use a ladder or lift to facilitate installation and to prevent the equipment from falling down and
causing personal injury or damage to the equipment. Do not use a ladder if you are alone and ⚫ If the PSUs are properly installed and connected to the external power supply, and the G5500
cannot get assistance. V7 server is standby (the power indicator is steady yellow), power on the server as follows:
Press the power button on the front panel to power on the server.
Power on the server using the iBMC WebUI.
Log in to the iBMC WebUI, choose System > Power > Power Control, click Power
⚫ Before touching a device, wear ESD gloves and remove any conductive objects, such as On, and click OK.
watches and jewelry. Power on the server using the iBMC CLI.
Log in to the iBMC CLI, run the ipmcset -d powerstate -v 1 command, and enter y or Y.
4 5 6