You are on page 1of 184
SIEMENS SIREGRAPH CF a AX Function Description RHD 32 As of Software Version VDO iemens AG 1994 Register 7 English Print No.: RXD3-209.041.01.03.02 Doc. Gen. Date: 12.98 Feglaces:XO0-209,0.01.02.02 0-2 Revision Chapter Page Revision all all 01 all all 02 all all 03 SIREGRAPH CF Register? RXO3-208.081.07 Page 2084 ‘Siemens AG Rev.03 12.98, TDTC21 Medical Engineering Contents 0-3 Page 1 Overview 1-1 SIREGRAPH CF Universal Remote Control Unit . 1-4 Overview of electronics cabinet 1-6 Motor drives, generators and potentiometers in the main unit 1-14 Motor drives, generators, potentiometers of the spotfilm device 1-16 Tableside control panel 3S1 1-17 Remote control console . 1-18 Overview of signal flow CPU board 2481 - - V0 board 2482 1-20 Layout of I/O board 24S2 . 1-24 Layout CPU board 24S1 1-36 Overview of microswitches 1-40 2 Power Supply. 2-1 Primary Power Supply. tee 12-2 Power Transformer 22TR1 Connections . 2-3 Transformer 22TR2 Connections 22-4 Voltage Distribution Transformer 22TR1 22-5 Voltage Distribution Transformer 22TR2 . 2-6 3 Remote Control Console 3-1 Remote Control Console Board Layout 3-2 Remote Control Console Connection . 63-5 4 Motor drives of the basic system 4-1 Speed control board for 22AZ3 column and 22AZ4 spotfilm device . 4-2 Safety circuit. 4-4 Main drive mechanical systems 4-6 Tilt drive electronics 4-12 Longitudinal carriage travel electronics . 4-16 Tube angulation electronics 4-24 Tomo sweep electronics. 4-34 5 Basic unit Minidrives. 5-1 Layout of the Minidrive boards: 5-2 Compression movement 5-6 SID drive (Source-to-image distance) 5-10 Transverse table drive 5-18 6 Basic system KK Interface and Collimator. 6-1 KK Interface Board 22S1 . . 6-2 Collimator Control Board 24S3 6-3 KK Interface 6-4 Somers AG Regu AXDSZOGOELOT —Fagesora SREGRAPA GF Medical Engineering Rev.03 12.98 TDTC21 0-4 Contents Page Multileaf Collimator 6-8 Filter 6 - 24 7 Spotfilm device 7-1 Layout of Spotfilm Device PC Boards . . Diaphragm Plate Travel Mechanical System . Diaphragm Plate Drive Electronics Format Sensing Mechanical System Format Sensing Electronics System Grid Drive. Cassette Carriage Control . Travel to the Load / Park Position 8 Changes to previous version 8-1 SREGRAPACF Rega AXDSDDSDETLOT Page 44 Somers AG fov.03 1258 Torcen Medica Engineering Overview 1-1 This page intentionally left blank. Siemens AG Rogistor7 FXOG-209.041.07 Page 1 of 2 SIREGRAPH CF Medical Engineering Rev.03 12.98 TDTc21 1-2 Overview Table of contents Chapter 1 SIREGRAPH CF Universal Remote Control Unit. Page 1- 4 General. Page 1- 4 Main features. Page 1- 4 Overview of electronics cabinet Page 1- 6 Generator connector block 22SC1 Page 1- 7 Generator connector block 22SC2. Page 1- 7 Safety circuit connector block 22SC3. Page 1- 7 Motor drive connector block 22TB1, Page 1- 7 Protective conductor connector block 22GNDO. Page 1- 7 Bus board connector block 23S10 for idrives. Page 1- 9 CPU board 24S1. Page 1- 9 VO board 2482. Page 1- 9 Collimator contro! board 24S3. Page 1- 9 Motor control board 22AZ2 in bus board 22S10. Page 1-9 Minidrive control in bus board 23S10. Page 1-11 KK Interface board 22S1. Page 1-11 22AZ3 Column and 22AZ4 spottilm device motor control boards. Page 1-11 Transformer 22TR1. Page 1-11 Transformer 22TR2. Page 1-11 Safety contactor assembly. Page 1-13 Motor drives, generators and potentiometers in the main unit. Page 1-14 Motor drives, generators and potentiometers of the spottfilm device.Page 1-16 Tableside control panel. Remote control console. Page 1-17 Page 1-18 Overview of signal flow for CPU board 2481 - I/O board 2482. Page 1-20 Pin assignment and signals. Page 1-21 VO board 2482 fuses. Page 1-23 CPU board 2481 fuses, Page 1-23 Programming switch board 241 Page 1-23 Programming switch DW1 (VO board) 2482. Page 1-23 Notice Page 1-23 SIREGRAPH GF Register? RXOS-208.081.07 Page 20142 ‘Siemens AG Rev.03 12.98 TTC at Medical Engineering Overview 1-3 Layout of I/O board 24S2. Page 1-24 Connections. Page 1-25 Fuses. Page 1-25 Programming switch DW1 Page 1-27 Potentiometers P1 - P6. Page 1-27 LED displays OUT. Page 1-27 Notice Page 1-29 LED displays IN. Page 1-31 Layout CPU board 24S1 Page 1-36 Connections. Page 1-37 Fuses. Page 1-37 LED's Page 1-37 Programmable switches J1 - J12. Page 1-37 Test points. Page 1-37 Nominal speed values, TP1 Page 1-37 Actual system position values, test point TP2. Page 1-39 Fiber optic cable connection. Page 1-39 Potentiometers. Page 1-39 Reset Button PL1. Page 1-39 Relays Page 1-39 ‘SPC Connectors Page 1-39 Overview of microswitches. Page 1-40 Siemens AG Medical Engineering Rogistor7 FXOG-209.041.07 Page 3 of 42 Rev.03 12.98 TDTC21 SIREGRAPH CF 1-4 Overview SIREGRAPH CF Universal Remote Control U: General ~ Fluoroscopy with the OPTILUX HDR 23-3 23 cm image intensifier (2 Zoom formats) or with the OPTILUX HDR 33-4 33 cm image intensifier (3 Zoom formats). - VIDEOMED DI TV system (systems A and B), VIDEOMED DH (system C) or VIDEOMED SX (system D). - POLYDOROS LX generator (system A) or POLYDOROS SX (systems B - D). - TV monitor or FLUOROSPOT COMPACT digital fluoro/ radiography system monitor. - Radiography mode with all cassette sizes from13 x 18cm to. 35 x 43 cmor 8" x 10" to 14"x 17”, film subdivision 2-on-1 to 4-on-1 for all cassette formats in width only (on the patient longitudinal axis). Series mode with a maximum of 4 exposures in 1.7 s. Or Hardcopy via the FLUOROSPOT COMPACT digital fluoro- radiography system with via laser camera. Oscillating grid PB 12/40 fo = 125 om (systems A and B) or stationary high-line grid PB 17/70 fo = 125cm (systems C and D) manually removable (optional). - Compression force (cone pressure) adjustable from 50 - 200N when the system is started up. ~ Tomographic technique independent of the system position. - Upto software version VCODA, the room height was programmable to 260cm, 285cm, 300cm and above 327cm. With software version VCO1A, the room height programming from 260em to 340em is programmable in 10cm steps. Main features : 9 drive from +90° to - 18° Trendelenburg at a speed of 6°/s, ~ Patient table 240 x74 om made of carbon fiber laminate, travel range -14/+ 15 om transverse only, speed 4 cm/s, ALequivalent value approx. 0.4 mm. - Table height 89 cm, swing-out step. + Longitudinal carriage travel range 154.cm. ~ Oblique projection maximum +/- 40° independent of the tomographic height selected. Automatic parallax correction of I ‘SIREGRAPH OF Rogistor7 FXOS-209.001.07 Page 4 of 2 ‘Siamens AG Rev.03 12.98 TDTc21 Medical Engineering Overview 1-5 - SID adjustable to 115 om, 135 om or 150. cm. Can be extended at a speed of 6 cm/s, depending on the system position and room height. ~ Motorized mutileat collimator including PBL mode and Manual mode (for overtable exposures) with standard accessory rails. Additional 0.2mm Cu filter can be moved into the beam path for pulsed fluoroscopy. 30s light, localizer timer, 150W light localizer lamp. ~ X-ray tube unit with manual swivel movement and 90° and 180° detents for bedside exposures (90°) or Bucky wall stand (180°) ~ Tomographic height 0 - 330mm, adjustable in 1 mm steps. - Linear tomographic technique 8° - 0.6s / 20° - 0.88 / 40°- 1.25, conventional or DFR technique. - Variable speed selection for “longitudinal carriage" travel, continuously adjustable from 0 - 5 cm/s, from remote control console only. Fixed operating speed from the tableside control panel. Alllother system movements have fixed speeds. Siemens AG Medical Engineering Rogistor7 FXOG-209.041.07 Page 5 of 2 SIREGRAPH CF Rev.03 12.98 TDTC21 1-6 Overview Overview of electronics cabinet VIDEOMED DI (if existing) not used with VIDEOMED SX and DH ‘CPU- board 2481 UO- board 2482 Multileaf collimator control board 2483 Backplane] SC1-SC5,AMP1,AMP2 22810 | Backplane 23510 Mini- Mihi drivp control Maestro 23AZ5 - 43Az8 22AZ2 Diaphragm Cassette plates jsaage Lemp ll D-| sw | 4 Maestro (Regulation boards) Column] Spot- no film TT idevice KK. interface AY msi 7 2eaza| 22024| [ | 10 2278 1]228C1[226Nt Connectors sci - sc7| FS1F32 (= 2arri F30 T At ria be 22K: . A] zaxe . ! F28 Fig — Z2TR2 5 I 5 | ons 2K2 a 2ziKt zat |S] 22F4 Power input F26 SIREGRAPH CF Register? AXDSZOOATOT Pago Sof @2 Siemens AG Rev.03 12.98 TDTC21 Medical Engineering Overview 1-7 Generator connector block 228C1 Generator connector block 228C2 Satety circuit connec- tor block 22803 Motor drive connec- The electronics cabinet comprises the following components and PC boards: - Column, generator 3071, connector block 22SC1 pin 1-3. Longitudinal carriage travel synchronized with the spotfilm device or ‘opposite the spotfilm device for swivel movement and tomography via pulse-width-modulated DC drives. - Spotfilm device, generator 3DT2, connector block 22SC1 pin 4-5. Longitudinal carriage travel synchronized with the column or opposite the column for swivel movement and tomography. - Cassette carriage, generator 3073, connector block 228C2 pin 4- 6. The generators produce an analog voltage in direct proportion to the actual speed. This actual value is required for speed regulation of the drives. Connections 22SC3 1-4 on board 22Stare for the safety circuit, safety con- tactor 21K1. Refer to Safety circuit, page 4-4 of the Function Description. The 3 motors are connected to speed regulation boards via connector block tor block 22TB1 (screw terminal block) 22TB1. - 22TB1 1-2connects motor 3MT1 column. ~ 22TB1 3-4 connects motor 3MT2 spotfilm device. - 228C2 1-2 connects motor 3MT3 cassette carriage. Protective conductor Al protective conductors (green/yellow) are connected to connector block connector black 22GNDO. 22GNDO Siemens AG Fogiter7 FRDS.ZOGOH.O Pago Tofa2 SIREGRAPH OF Medical Engineering Rev. 03 12.58 qoTc 21 1-8 Overview VIDEOMED DI (if existing) not used with VIDEOMED SX and DH CPU- board 2451 VO- board 2482 Multileaf collimator control board 2483 Backplane \ Backplane 23810 Mini drive contfol 23AZ5 - 23AZ8 Diaphragm Cassette plates carriage (asc: aS: enor | D-|se we Maestro (Regulation boards) za (otf spat 2202 device KK- Interface A ev 2281 22023 | 22Az4| (lo 5 (ll 2271 228¢1[22GN Connectors sc1_- sc7| F31F32 =) 2aTr1 F29 F30 T A Fi4 bo 22K . 22K2 - F28 . Fi4 L a 22TR2 | 1 Ea FAIS 21K2 21K1 211 YX] 2261 Power input F26 ‘SIREGRAPH OF Rogistor7 FXOS-209.001.07 Page 8 of 42 ‘Siamens AG Rev.03 12.98 TDTc21 Medical Engineering Overview 1-9 Bus board connector block 23810 for $C1-SC5 Power supply for minidrives. minidrives: AMP1 Input / output signals. AMP2 Measurement signal proportional to compression force CPU board 2481 CPU (processor) board 2481 is located behind /O- board 2482. It controls all movements of the spotfilm device and the basic system and communicates with the tableside control panel, the remote control console (via fiber optic cables) and with the generator (via the KK Interface) This board contains potentiometers, fuses, test points TP1 (nominal speed values) and TP2 (actual system position values), as well as LED's and the Reset button. The CPU board is described on page page 1-36 of the Function Description. VO board 2482 VO board 2482 is located in front of CPU (processor) board 24S1, This board contains LED's and programming switch DW1 The I/O board is described on page 1-24 of the Function Description Collimator control The collimator control board is located underneath V/O (Input / output) board board 2483. 2482. It is described on page 6-9 of the Function Description. Motor contro! board The “Mini Maestro” board regulates the speed of the cassette carriage. 22AZ2 in bus board —_This board is described on page 7-3 of the Function Description. 22810. Siemens AG Fogiter7 FRDS.ZOGOH.O Pago Sofa2 SIREGRAPH OF Medical Engineering Rev. 03 12.58 yore 21 1-10 Overview VIDEOMED DI (if existing) not used with VIDEOMED SX and DH CPU- board 2451 O- board 2482 Multileaf collimator control board 2483 Backplane SCA-SC5,AMP1,AMP2 22810 Backplane 23510 Mini- Mini drive contfol Maestro 23AZ5 - 23828 22AZ2 Diaphragm Cassette plates jsaniate Lemp ll Dr} sw | 4 Maestro (Regulation boards) [Columal Spot- = ie T device KK- Interface Gy, A ast 22Az3| 22Az4| [ 10 | 22781 p2801]22GN0) Connectors 1 - sc7| FS4F32 =) 2atri F30 A Ftd Le zaKs . 22K2 : a | | oz ea] FAS. T T 21k2 KT 1A OL) 22F4 Power input F26 SREGRAPH GF Regier AXDSDDADILOT Page 10 ofa STemane AG Rev.03 12.98 TDTc21 Medical Engineering Overview 1-11 Minidrive control in bus board 23810. KK Interface board 2281 22AZ3 Column and 2224 Spotfilm device motor contro! boards The DC servo motors are activated via the minidrive control boards. - Collimator blade motor control board 23AZ5, motor drive 3MTS. - Compression cone motor control board 23AZ6, motor drive 3MTE. ~ Source-to-image distance (SID) motor control board 23AZ7, motor drive 3MT7. - Transverse table control board 22AZ8, motor drive 3MTS. These boards are described on page 5-4 of the Function Description. Communication between the CPU board 2481 and the generator takes place via the KK Interface. The board is described on page 6-2of the Function Description. These boards regulate the speed of the column and the spotfilm device for synchronous travel in the same direction as the longitudinal carriage and in the opposite direction for swivel movement, tomography and tomographic height adjustment. The boards are described on page 4-2 of the Function Description. Transformer 22TR1 Supplies power to the tilting, spotfilm device, column and cassette carriage motor drives. ‘The connections are described on page 2-3 of the Function Description. Transformer 22TR2 Supplies power to the processor board, displays, remote control console and idrives. The connections are described on page 2-4 of the Function Description. Siemens AG Fogiter7 FRDS.ZOGOH.O Pago Tota SIREGRAPH OF Medical Engineering Rev. 03 12.58 qorc 21 1-12 Overview VIDEOMED DI (if existing) not used with VIDEOMED SX and DH CPU- board 2451 NO- board 2482 Multileaf collimator control board 2483 Backplane] ‘SC1-SC5,AMP1AMP2 22810 | ickplane 23810 Mini- Mini drive contfol Maestro 23AZ5 - 23AZ8 22022 Diaphragm Cassette Plates |eariase Lemp ll D>} so | 4: Maestro (Regulation boards) [Columnl spot- ZL Fa T device KK interface gy, A 2281 22Az3 | 22474] | 10 ili 22781 p2801]22GND, Connectors sc1 - sc7| F91F32(=) 2atrt F30 TF Ftd L, 22K1 . 22K2 : | ! Sow =e FAs T T 21K2 IKI 21M XY] 22F4 Power input F26 SREGRAPH GF Regier AXDSDDADILOT Page 12 ofa STemane AG Rev.03 12.98 TDTc21 Medical Engineering Overview 1-13 Safety contactor The safety contactor assembly consists of: assembly - Safety contactor 21K1 with timer for switch-on attenuation and 21K2 a turn-on attenuation of approx. 1 second, - Contactors 22K1 and 22K2 for the tilt drive (rotational sense contactors) - Capacitor pack 22C1 and 22C2 for smoothing the power supply for minidrives 23AZ5 - 23AZ8 and the cassette carriage, motor drive 22AZ2. - 21A1 3-phase line connection circuit breaker. Siemens AG Rogistor7 FXOG-209.041.07 Page 15 of 42 SIREGRAPH CF Medical Engineering Rev.03 12.98 TDTc21 1-14 Overview Motor drives, generators and potentiometers in the main unit tts oo SIREGRAPH OF Rogistor7 RXDS-208.047.07 Page 14 of 42 ‘Siemens AG Rev.03 12.98 ToTca21 Magical Engineering Overview Number Potentio- Generator Motor Drives meter Il POTI wm Collimator height 1 POTI MTI — Collimator width 1 3PT1 —-3DT1 3MT1 Column 2 3PT2 © 3DT2 3MT2 —_Spottilm device 4 3PT4 3MT4 Tilting 6 3MT6 Compression 7 3PT7 3MT7_—SID 8 3MT8 —_ Table, transverse head-end beam Siemens AG Rogistor7 FXOG-209.041.07 Page 15 of 42 SIREGRAPH CF Medical Engineering Rev.03 12.98 TDTc21 1-16 Overview Motor drives, generators, potentiometers of the spotfilm device View: from the back, system in +90° position \ Ld | Cassette carria apeetecerags 3PT10 Tableside control panel Number Potentio- Generator Motor Drives meter 3 3PT3-3DT3. 3MT3 Cassette carriage 5 3PT5 3MT5 —_Collimator blades Width 10 3PTIO Format sensing Cassette width n SPT Format sensing Cassette height SIREGRAPH GF Register? RXOS-208.081.07 Page 16 0f 42 ‘Siemens AG Rev.03 12.98 TDTc21 Medical Engineering Overview 1-17 le control panel 3S1 |_| L13 L414 L415 nS Ke OO eoo0ed ol | "| P24 P22 P23 P43A P43B P42A P42B P44A PAAC| P39A P44D AMP1 24 -pole connector, provides connection to the /O board in the electronics cabinet Li3rt__ LED display, 115 cm SID. L14rt_ LED display, 135 cm SID. Li5rt__ LED display, 150 om SID. P21 SID selection button, 115 cm. P22 SID selection button, 135 cm. P23 SID selection button, 150 cm. Buttons P21 - P23 must remain activated in order to reach the desired SID! P39A Cassette carriage load / park position P39B On the inside of the cover, cassette carriage load / park position P42A Tilt system. P42B Tilt system upward. P43A Swivel toward the head-end. P43B Swivel toward the foot-end. P44 Longitudinal carriage travel toward head-end (constant speed ramp speed) P44B Transverse table travel toward wall side P44C Longitudinal carriage travel toward foot-end (at constant speed + ramp speed). P44D Transverse table travel toward physician's side. Siemens AG Fogiter7 FXDS2OGDUT.OT Page 17 ofa2 SIREGRAPH CF Medical Engineering Rev.03 12.98 TDTc21 Overview Remote control console Emergency stop P2 P3 P4 PS -P6 P7 PB P9P10 P11 P12 P13 P29 P17 P18 P19 P20 P21 P22 P23 P24 P25 P26 P27 PSO P15 P14 P28 Pas gt ps2 Ini] pst as par pss Fy D38L46 J ° P40 Pat P35 pas ©) o o P42 P43 © Pas a Oo P2 Selection button, LI. survey format. P3 Selection button, Zoom 1. P4 Selection button, Zoom 2. P5 Selection button, Zoom 3. P6 —_ Selection button, spotfilm device mode (Bucky mode). P7 _ Selection button, Tomography 8° - 0.6s. P8 Selection button, Tomography 20° - 0.88. P9 Selection button, Tomography 40° - 1.2s. P10 Selection button, full format. P11 Selection button, 2-on-1 subdivision. P12 Selection button, 3-on-1 subdivision. P13 Selection button, 4-on-1 subdivision. P14 Selection button, DR (Digital Radiography). P15 Selection button, Direct technique. P17 Selection button, Fluoro 1 (Automatic Dose Rate Control ADR1). PIs Selection button, Fluoro 2 (Automatic Dose Rate Control ADR2). P19 Image reverse key right/ left (R / L) SIREGRAPH CF Register? BROSDONOITOT Page T8oFA2 Siemens AG Rev.03 12.98 TDTc21 Medical Engineering Overview P20 P2t P22 P24 P24 Image reverse key (headward / footward). Selection button, Fluoro stop (Automatic Dose Rate Control stop ADR stop). Selection button, 115 cm SID. Selection button, 135 em SID. Selection button, 150 em SID. Buttons P22 - P24 must remain activated in order to reach the desired SID! P25 P26 P27 P28 P29 P31 P32 P33 P34 P35 Selection button, left IONTOMAT measurement field, from cassette size >/= 24 om wide/high and full format. Selection button, center IONTOMAT measurement field. Selection button, right IONTOMAT measurement field, from cas- sette size >/= 24 om wide/high and full format. Selection button, series mode for cassette operation or DR (Digital Radiography), Button, Room lighting. Selection button, PBL system (automatic) / Semi-automatic for cassette exposures Selection button, Spotfilm device mode / Bucky mode. Selection button, Collimator light localizer "on" . Button, move tomographic height UP. Button, move tomographic height DOWN. With oblique projection, activating buttons P34 and P35 does not result in visible movement of the spottilm device or the column The projection angle is not altered during oblique projection in Bucky mode! P37 P39 P40 P41 P42 P43 P44 P45 Pas P50 D36 p38 Selection button, Swivel angle 0° ( 0° - reset button, must remain activated until the 0°- swivel angle position has been reached) Button, cassette carriage Load or park position. Joystick, multileaf collimator contact switch (fixed speed) Joystick, compression (constant speed) Joystick, tilting down / tilting up (constant speed. Joystick, swivel angle (constant speed). Joystick, longitudinal carriage (variable speed, selection via potentiometer P44 A-C) and table transverse movement, variable speed, selection via potentiometers P44B and P44D. VK / HK, Preparation / Exposure release button. Button, 0° tilt angle - stop bypass. Selection button, “round field with DFR" (digital fluoro radiogra- phy). Displays the tomographic height selected in mm or error code. Displays the number of exposures left on cassette. L46ge Radiation ON indicator. Siemens AG Rogistor7 FXOG-209.041.07 Page 19 of 42 SIREGRAPH CF Medical Engineering Rev.03 12.98 TDTc21 1-20 Overview Overview of signal flow CPU board 24S1 - I/O board 2482 CPU 2481 Power supply VO 2482 21VAC CNS|< Power supply —— J1- 13 |Watchdog —<— PL1 Reset P4- P14 fo TT1P1 [cnt OUT analog 1-12 cN4 TTP2 [CNA—_________lenQ IN analog 1-12 IN digital 1-48 TEST F1-F4 (CN4--—___________EN4) $+ L73- L96 IN digital 25-48 CN —______lengg| . IN digital 1-24 ¥ 49-172 CN OUT digital 25-48 [CNS ¥ L25~ 148 CNT our digital 1-24 J°NZ # L1-L24 cng IN digital 1-48 Test |CN8' EPROM EEPROM ON /CORCEECT Dw1 OFF OMsoa0o8) Pen a (©) Fiber optic cable [ Remote control 2483 LAMP1] console IMulttileaf collimato control SREGRAPHOF Regular AXOSZOBDUT.OT Pago a0 oF Siomans RG Rev.03 12.98 TDTC21 Medical Engineering Overview 1-21 Pin assignment and signals Pin assign ments Nt cn2 Ns Na CNS cN6 cN7 Ns Sct Signals OUT analog 1 - 12. Voltages proportional to Ung Nominal speed values for system travel, can be measured at TP1 CPU board 24S1. Refer to page 1-37 of the Function Description. IN analog 1 - 12. Voltages from actual value potentiometer Uact for system posi- tions, can be measured at TP2 CPU board 24S1. Refer to page 1-39 of the Function Description. IN digital 1 - 48, For PC test (function test of the VO board 24S2 and CPU board 24s1. IN digital 25 - 48. Signals from the system microswitches and programming switch DW1, displayed by LED's L73 - L96 on I/O board 2482. Refer to page 1-35 of the Function Description. IN digital 1 - 24, Signals from operating switches displayed by LED's L49- L72.0n the /O board 2482. Refer to page 1-31 of the Function Description. OUT digital 25 - 48. Status and control signals e.g. operating switches, interface con- trol, displayed by LED's L25 - L48 on 0 board 2482. Refer to page 1-29 of the Function Description. OUT digital 1 - 24. Status and control signals e.g. power supplies, LED controls, operating switches, displayed by LED's L1 - L24 on /O board 2482. Refer to page 1-27 of the Function Description. IN digital 1 - 48, Test. 21VAC power supply. Siemens AG Medical Engineering Rogistor7 FXOG-209.041.07 Page 21 of 42 SIREGRAPH CF Rev.03 12.98 TDTC21 1-22 Overview CPU 2481 Power supply] 1/0 2482 21VAC Nal {SCH Power supply —~— J1-J13 | Watchdog —~ PL1 Reset P1-P14 TT1P1 ICN OuTanalog1-12 (oN T1P2 [eN cna IN analog 1-12 CN3k Th aigital 1-48 Test (CNS) —— F1-F4 [CN CN4] ¥= L73-Lo6 IN digital 25-48 * Na ens - IN digital 1-24 JENS ¥ L49-L72 GN OUT digital 25-48 |CN@ ¥ L25--L48 CN OUT digital 1-24 {EN ¥ Lt-L24 CN IN digital 1-48 Test |CN8 EPROM EEPROM ON rr Ommcmoom @~ Fiber optic cable [ Remote control 2483 AMP1 console IMuttileaf collimator [control SRG Regie axOSaTB DNL OT Page ora Samana 5S Rev.03 12.98 TDTcG21 Medical Engineering Overview 1-23 VO board 2482 fuses: Rating: 46AT F1 F2 FS FS FS F6 fuse- protected outputs 1-8 9-16 17-24 25-32 33-40 41-48 OUT digital CN6, CN7. CPU board 24S fuses FI aat 16Vac F2 1.250T* —10Vac F3 1.2507 —19Vac F4 1.25AT —19Vac Programming switch CPU board 2481 J1u2 ON Fixed programming, not to be changed 33 OFF Fixed programming, not to be changed wa ON Fixed programming, not to be changed J5-J12 ON __ Fixed programming, not to be changed 13 ON Fixed programming, not to be changed Programming switch DW1 VO board 2482 Room height >327em max. 300em = max. 285cm max. 260em ON I uy OFF a ql Digital Radiography No Yes ON (on ini cio OFF i 0 Voliformat ON fociajaIag OFF (no an Wi Adjustment cm Inch Mode ON fee rr tt OFF [ddcblotio lidolobdomo) §—otobota Notice: AAs of software version VCO1A ( with the Gorla collimator only), dip switches DW 1.1, DW 1.2 and DW 1.6 have no function. The room height is pro- grammed via codes 201 (3.40 m) to 209 (2.60m) in 10cm steps in adjustment mode. DFR is programmed via codes 211 (with DFR), 213 (without DFR) and 212 (DFR as default position) in adjustment mode. Siemens AG Register? FXDS2OGDUT.OT Page 23 of 42 SIREGRAPH CF Medical Engineering Rev.03 12.98 TDTG21 1-24 Overview Layout of I/O board 24S2 ‘MP2 AMP3 CNz7| AMP1 i cP10 CP11 CP12 sc7 Q Q Q N14 CN2 cNi CP7 CP8 CP9 CNG CP4 CP5 CP6 on CP1 CP2 CP3 sce cN3 LI CNS scs sca sc3 U CN sc2 sc1 CECA (AMP) AMPS |— ‘SIREGRAPH OF Rogistor7 FXOS-209.001.07 Rev, 03 12.98 Page 24 of 42 TDTcC21 ‘Siamens AG Medical Engineering Overview 1-25 Connections (CN1-CN8 Refer to page 1-19 of the Function Description. CFC1 KK- Interface connection. AMP1 Microswitches, basic system end positions. AMP2 Operating button signals, spotfilm device tableside control panel 3S1 AMP3 Allarmax connector for interference suppression and adjust- ment mode. AMP4 Bus 23$10 minidrive controllers for collimator blades, com- pression, SID, table transverse movement. AMP5 Multileaf collimator control 24S3. sct 21Vac power supply. sc2 Tilting drive. ‘sc3 Bus 22S10 "Mini Maestro”, cassette carriage analog signals. sca not used. ‘SCS Column, analog voltages, power supply to 22AZ3 “Maestro”, speed control. ‘SC6 Spotfilm device, analog voltages, power supply to 22AZ4 "Maestro", speed control. ‘Sc7 Grid solenoids SOL1 "grid travel" and SOL2 "center park position " and induction switch XS2 "grid contact” CPI Actual value potentiometer, tilt drive 3PT4. cP2 not used. cP3 Actual value potentiometer, column 3PT1 cP4 Actual value potentiometer, spotfilm device 3PT2. CP5 Actual value potentiometer, SID 3PT7. CP6 Voltage proportional motor current 3MT6 compression. CP7 Actual value potentiometer, collimator width. CPs Actual value potentiometer, collimator height. cP9 Actual value potentiometer, collimator blades 3PTS. CP10 Actual value potentiometer, format sensing, cassette width 3PT10. cPi1 Actual value potentiometer, format sensing, cassette height 3PT11. cPi2 Actual value potentiometer, cassette carriage 3PTS. Fuses F1-F6 Refer to page 1-23 of the Function Description. Siemeng AG Register? ANDSZOROITOT Pago 250F42 SIREGRAPH GF Modieal Engineering Rew.03 1258, Torea! 1-26 Overview F1 CN7 l us - ou PLA F2 60000000 L16 - tg OLS7 F3 OOOOOO0O L24 = L17 OL9B8 Fa OO0000CO sz = Lag OL 99 fl OOO0O00CCO F5 OL100 - _ 133 ll dc OOO0000CO F6 Sg OEtO i 60006006 L51Q LOO 1490 1540 1630 1520 Ls7Q LQ 1L55O L600 L590 158 O \ss QO Le220 LO Lee L65O L640 DWi-1bis1-8 169 Q L6eBQ L670 17220 L170 L700 L75Q L74Q L730 t7%8O L77O L75O 181Q 1890Q L790 Ls4O 1830 182 O L87Q L86Q La O L990 QO =L89 O88 O 193Q L920 L910 t96O L95O 1940 Pi =P coo AMPS SIREGRAPH CF Register 7 ARDS2OGOH.O Page 25 of 42 Siemens AG Rev, 03 12.98 TDTC21 Medical Engineering Overview 1-27 Programming switch Dwi Potentiometers P1- P6 LED displays OUT DW1-1, DW1-2 pw1-3 DW1-4, DW1-5 Dwi-6 Dw7 pws Programming of room height up to the software version Voo0A. Li. size Number of zoom formats, Zoom! - Zoom 3. DFR up to software version VCOOA. Cassette format in "em" or “inches”. Adjustment mode (for adjusting potentiometers and sys- tem positions) Refer to page 1-23 of the Function Description. P1 Adjustment of exposure "ON" signal, 40° Tomography with DFR. P2 Adjustment of exposure "ON" signal, 40° Tomography normal P3 Adjustment of exposure "ON" signal, 20° Tomography with DER. P4 Adjustment of exposure "ON" signal, 20° Tomography normal P5 Adjustment of exposure "ON" signal, 8° Tomography with DER. P6 Adjustment of exposure "ON" signal, 8° Tomography / normal. LED Pin Function OUT digital Lign OUT Control signal, system to 0° position Lagn OUT.2 Control signal, tit system. L3gn OUT.3 Grid control solenoid SOL1, "on" at main contact HK (systems A and B only). Lagn OUT4 Grid control solenoid SOL2. Grid in park position, “on” at precontact VK (systems A and B only). L5gn OUTS not used Légn OUT. not used L7gn OUT? not used Legn OUT.B not used, Lagn OUTS LED 115¢m SID “on”, tableside control panel. L10gn OUT.10 Ltign OuT.11 Li2gn OUT.12 L13gn OUT.13 L14gn OUT.14 L15gn OUT.15 Li6gn OUT.16 LED 135m SID "on", tableside control panel. LED 150m SID "on", tableside control panel. Spotiilm device, motor controller 22AZ4, motor 3MT2 Column, motor controller 22AZ3, motor 3MT1. Cassette carriage, motor controller 22AZ2 motor 3MT3. not used Collimator blades, motor controller 23AZ5, motor 3MT5. Siemens AG Medical Engineering Rogistor7 FXOG-209.041.07 Page 27 of 42 SIREGRAPH CF Rev.03 12.98 TDTC21 1-28 Overview fA () cnz Ls - 1 PL F2 OOOOOO0O, Lig tg OL97 3 OO000000, L24 117 OL%8 fl @OOOOO00O F4 132 - L2gOL99 00000000 ce F5 L40 - 133 OO000000 OL101 Las : 5 OOO000000, ——- 161Q L50Q 1490 40 1530 1520 Ls7Q L56Q L55O L600 1590 58 O LE3Q LE2Q L610 Le6O L65O 1640 LE9Q L6BQ LE7O L720 L110 LO L75Q L74Q L730 L720 L770 L750 L81Q L8I0Q L79O La4O 1830 L820 L87Q LB6Q LB L900 18988 O L93Q L92zQ 110 w6O 1950 1940 AMP5 ‘SIREGRAPH OF Rogistor7 FXOS-209.001.07 Page 28 of 42 ‘Siamens AG Rev.03 12.98 TDTC21 Medical Engineering Overview 1-29 LED Pin Function OUT digital L17gn OUT.17 — Compression drive, motor controller 23AZ6, motor 3MTE. L18gn OUT.18 SID drive, motor controller 23AZ7, motor 3MT7. Li9gn OUT.19 Transverse table drive, motor controller 23AZ8, motor MTs. L20gn OUT20 —_notused. L21gn OUT21 Operating signal, collimator lamp "on". L22gn OUT.22 — Up to software version VCO: "Off" when the collimator drive is being activated. "ON" when the collimator blades are in the position set by the control circuit As of software version VDO: 0.2mm Cu filtration in the beam path L23gn OUT.23 —*Collimator in manual mode" (e.g. swiveled out). L2agn OUT.24 Signal on KK Interface 2281, center IONTOMAT measurement field selected. L25gn OUT.25 Signal on KK Interface 2281, left IONTOMAT mea- surement field selected. L26gn OUT.26 Signal on KK Interface 2281, right IONTOMAT mea- surement field selected. Notice: Chamber selection automatically reverts to the center measurement field if the cassette format width andlor height is less than 24 cm or if subdivision is selected. L27gn OUT.27 Signal on KK Interface 2281, AC signal on ION- TOMAT, if collimation is less than 12 cm due to colli- mator width ("cone contact"). L28gn OUT.28 Signal on KK Interface 2281, unassigned button activated, not used. L2agn OUT.29 Signal on KK Interface 2282, "DS" Fluoroscopy ‘on’ L30gn OUT.30 Signal on KK Interface 2281, "VK" series contact, activated, L31gn OUT.31 Signal on KK Interface 2281, "HK" Main contact activated, L32gn OUT.32 Signal on KK Interface 22S1, image inversion selected. L33gn OUT.33 Zoom 1 selected. L3agn OUT.34 Zoom 2 selected. L35gn OUT.35 Zoom 3 selected. Siemens AG Register? RXOS-208.041.07 Page 29 of 42 SIREGRAPH GF Medical Engineering Rev.03 12.88 TO TC at 1-30 Overview FA il L8 - Li PL F2 OOOOOO000, tl L16 Lg OL97 OOO00000 fe L26 Liz O18 OOO00C000, F4 132 L2s OL99 00000000 CNG OL100 F5 140 - 133 @OOOOC000 OL101 Fe L48 -_ Ll ll @OOO00000 6510 L0Q L440 1540 1530 1520 Ns Ls7Q L56Q 1550 LeoO 1590 158 O : L63Q L62Q L61Q L66Q Lé5OQ L164 O Le9Q L68Q LE7O L720 L710 LO L75Q L74Q L73Q t7eO L770 175 O 181Q 180Q L79O La4O 1830 L820 L87Q LEO LEO L900 L890 L88 O 1933Q 192Q 1910 w6O 1990 1940 AMP5 SIREGRAPH CF Register 7 ARDS2OGOH.O Page 30. of42 Siemens AG Rev.03 12.98 TDTC21 Medical Engineering Overview 1-31 L36gn OUT.36 Direct Technique selected. L37gn OUT.37 DR selected. L38gn OUT.38 Room lighting L39gn_ OUT.39 Fluoro 1 (ADR1) selected. L40gn OUT.40 Fiuoro 2 (ADR2) selected. L4ign OUT.41 Fiuoro stop (ADR stop). L42gn OUT.42 A 0.6s tomographic time selected. L43gn OUT.43_B 0.8s tomographic time selected. Laagn OUT.44 C 1.2s tomographic time selected L4Sgn OUT.45 Signal on KK Interface, series mode for cassettes or DR selected, only if 2-on-1 or 4-on-1 or subdivision is, selected. L46gn OUT.46 not used. L47gn OUT.47 not used. L48gn OUT.48 not used. LED displays IN Laggn IN.1 KK Interface, power “on” (power on). L50gn IN.2 KK Interface, exposure, "as signal”. L5ign IN.3 Disable via safety contact (e.g. door contact). L52gn IN.4 3D parked position L53gn IN.5 — notused. L5agn IN.6 — notused. L55gn IN.7 — notused. L56gn IN.8 — Microswitch 3FCS activated. Spottilm device travel in the direction of the tabletop frame disabled due to angulation or tube carriage drive. This prevents the comparatively wider counterbalance located on the physician side longitudinal beam from hit- ting the table frame. L57gn IN.9 Systems A and B: "Grid contact”, induction switch XS2 actuated. Systems and D: high-line grid in the beam path "OFF": High-line grid manually removed (optional for sys- tems C and D) L58gn IN.10 "Off" tube swiveled to I.I., microswitch 3FC1 actuated. (open). Normal mode. L59gn_IN.11 “Column” drive, power supply present for controller board 22423. Siemens AG Register? RXOS-208.041.07 Page 31 of a2 SIREGRAPH GF Medical Engineering Rev.03 12.88 TO TG at 1-32 Overview FA oO fis - wu PL F2 00000000 te - tg OL97 00000000 F3 ~ Lay OL98 ih dc OOO00000 Fa 132-25 OLS il OCOCC00O OL100 F5 L40- 33 ' OCOCC00O 48 ~ pay OL il 60000060 CN5 L1Q L0Q La OQ 1540 1530 1520 L67QO L56Q L55O Lte0O L590 158 O L63 L62 Let L66 8 L65 8 L64 8 L69 Q L68 L67 L720 L1QO L706 LI5Q L4OQ L736 L720 LI7O LO 1810 L800 OQ LIQ L84Q 188O L820 L187 Q L86 L85 1900 L899 L8 S L933 Q L92 Lot 6 LH L946 AMPS SIREGRAPH CF Register 7 ANDSZOGON.OT Page Sof 42 Siemens AG Rev.03 12.98 TDTc21 Medical Engineering Overview 1-33 LED Le0gn Letgn Le2gn Le3gn L6agn Lesgn Le6gn Le7an Legon Leagn L7ogn L7ign L72gn L73gn L7agn L75gn L76gn L77gn L7@gn Lagn Leogn Pin IN digital INA INA3 INAa INA5 INA INA7 INAB IN19 IN.20 IN.21 IN.22 IN.23 IN.24 IN.25 IN.26 IN.27 IN.28 IN.29 IN.30 IN31 IN.32 Function "Spotfilm device" drive, power supply present for con- troller board 22AZ4 Transverse table limit switch 3FC8 activated on "wall side” Transverse table limit switch 3FC9 activated on "phy- sician side" not used. not used. Multileaf collimator controller board 24S3 functional, always “off’, if X-ray tube is swiveled out 90° or 180°. Tube limit switch maximally decompressed (park posi- tion) 3FC2 actuated. Microswitch 3FC3 actuated, cone inserted. Micros (actuated) 3FC4 cone inserted and com- pression pressure > 50N. Basic system movements longitudinal carriage", /el angle" and "tomography" disabled. not used. not used. not used. not used. DW 1-1 Programmable pin assignment, room height up to software version VCOOA. DW 1 - 2 Programmable pin assignment, room height up to software version VCOOA. DW 1-3 Programmable pin assignment, II. format. DW 1-4 Programmable pin assignment, |. format. DW 1-5 Programmable pin assignment, no. of zoom formats DW 1 - 6 Programmable pin assignment, Digital Radi- ography up to software version VCOOA. DW 1-7 Programmable pin assignment, "cm"- or “inch-* formats DW 1-8 Programmable pin assignment (Adjustment mode). After software version VCO1A, the room height is programmed by adjustment codes 201 - 209 in 10cm steps from 260em to 340em. Digital radiography is programmed by adjustment codes to 211 - 213. Siemens AG Rogistor7 Medical Engineering FXOG-209.041.07 Page 33 of 42 SIREGRAPH CF Rev.03 12.98 TDTG21 Overview oO L8 Li PL fy OOOOCOOO Lis Lg OL97 OCO00000 L24 = 17 OL OCO00000 F4132- L325 OL99 O0000000 @L100 L40 - 133 OCOC000O Lat L48 - 4 F6 OOOOO000, L51Q L50Q L49Q i640 1530 1520 Ls7Q L56Q L155 O LeoO 1590 158 O LE3Q LE2Q L610 Le6O L650 1640 Le9Q L6BO L670 L720 L710 L700 L75Q L740 L730 L73O 1770 L750 | L81@ L80Q L79O cna || La4O 1830 1820 | L87@ Lee O LEO [ L90O «189 O88 O L93Q@ L920 1910 w6O 1950 1940 AMPS SIREGRAPH CF Register 7 ARDS2OGOH.O Page 34 of 42 Siemens AG Rev.03- 12.98 qorc2t Mecical Engineesing Overview 1-35 LED Pin Function IN digital L8ign IN.33 not used. L82gn_IN.34 not used. L83gn_ IN.35 not used. L84gn_IN.36 not used. L85gn_IN.37 Control button, tableside contro! panel P39 A/B cas- sette carriage load / park position actuated. L86gn_IN.38 Control button, tableside control panel P44B transverse table travel toward "physician" side actuated. L87gn_IN.39 Control button, tableside control panel P44D transverse table travel toward “wall” side actuated. L88gn_IN.40 Control button, tableside contro! panel P44A “head- ward" travel of longitudinal carriage actuated. L89gn_IN.41 Control button, tableside control pane! P44C "footward” travel of longitudinal carriage actuated. L90gn_ IN.42 Control button, tableside contro! panel P42A system “tilting” actuated. L9ign IN.43 Control button, tableside contro! panel P42B system “upright” actuated. L92gn IN.44 Control button, tableside control panel P43A swivel movement "headward" actuated. L93gn IN.45 Control button, tableside control panel P43B swivel movement "footward" actuated. L94gn IN.46 Control button, tableside control panel P21 115cm SID actuated. L95gn IN.47 Control button, tableside control panel P22 135cm SID actuated. L96gn IN.48 Control button, tableside control panel P23 150cm SID actuated. L97rd Short circuit. Protects driver U1 in case of a short. Actu- ate Reset - button PL1. L98rd Short circuit. Protects driver U2 in case of a short. Actu- ate Reset button PL1 L99rd Short circuit. Protects driver U3 in case of a short. Actu- ate Reset button PL1 L100rd Short circuit. Protects driver U4 in case of a short. Actu- ate Reset button PL1 Lidird Short circuit. Protects driver US in case of a short. Actu- ate Reset button PL1 Siemeng AG Register? ANOS DOROITOT Pago 350742 SIREGRAPH GF Modieal Engineering Rew.03 1258, Torea! 1-36 Overview Layout CPU board 24S1 CNS CN7 eo L112 CNG Fst - 53 ca J5-J12 CNS P14 J4 um CNA SIREGRAPH CF Register 7 ARDS2OGOH.O Page 36 of 42 Siemens AG Rev.03- 12.98 TDTc2t Mecical Engineering Overview 1-37 Connections (CN1-CN7 Refer to page 1-21 of the Function Description. Ng Power supply and watchdog, Fuses Fi 4ay 16Vac F3 1.254" 19Vac F2 1.254" 10Vac Fa 1.25A* 19Vac * slow-blow LED's Lirt Input / output error, EEPROM defective, power supply detective. L2gn Circuit OK. L3gn Watchdog CPU board 24S1 did not respond, O.K. Programmable switches J1 - J12: Jt ON plugged in, not to be changed 2 ON plugged in, not to be changed J3 OFF removed, not to be changed J4-J13 ON _ plugged in, not to be changed Test points Nominal Speed Values TP1 TP1-1 _Unom column, analog voltage OUT. TP1-2 __Unom spotfilm device, analog voltage OUT. TP1-3 _Unom cassette carriage, analog voltage OUT. TP1-4 —notused. TP1-5 — Unom collimator width, analog voltage OUT. TP1-6 —_Unom collimator height, analog voltage OUT TP1-7 _notused. TP1-8 —_Unom collimator blades, analog voltage OUT TP1-9 not used. TP1-10 not used. TP1-11_Unom SID, analog voltage OUT. TP1-12 notused. TP1-13 OV analog voltage OUT (Reference point for measuring the potentiometer voltages at test points TP1-1 to TP1-12). TP1-14 OV analog voltage OUT (Reference point). Siemens AG Register? RXOS-208.041.07 Page 37 of a2 SIREGRAPH GF Medical Engineering Rev.03 12.88 TO TG at 1-38 Overview TP2 P13 P12 P14 P10 ~_ qt] aaa _ q_) =_p9 o_]P8 =__Ip7 o_]P6 q_] ~_ q_) PS Pa P3 sPC CN3 TX1 RX1 ca YY ‘SIREGRAPH OF Rogistor7 FXOS-209.001.07 Page 38 of 42 ‘Siamens AG Rev.03 12.98 ToTC21 Medical Engineering Overview 1-39 Fiber optic cable con- nections Actual System Position Values Test Point TP2: TP2-1 Uact tilting, potentiometer 3PT4, analog voltage IN. TP2-2 not used. TP2-3 Uact “column” potentiometer 3PT1, analog voltage IN. TP2-4 Uact “spottilm device” potentiometer 3PT2, analog voltage IN. TP2-5 Uact SID potentiometer 3PT7, analog voltage IN. TP2-6 not used. TP2-7 _Uact collimator width potentiometer POT Il, analog voltage IN. TP2-8 Uact collimator height potentiometer POT I, analog voltage IN. TP2-9_Uact collimator blades potentiometer 3PTS, analog voltage IN. TP2-10 Uact format sensing, width, potentiometer 3PT10, analog voltage IN ‘TP2-11 Uact format sensing, height, potentiometer 3PT11, analog voltage IN TP2-12 Uact cassette carriage potentiometer 3PT3, analog voltage IN ‘TP2-13 Potentiometer voltages at test points TP2-1 to 2-12. TP2-14 OV analog voltage IN (Reference point for measuring potentiome- ters TX1/ Transmitter/receiver FOC communication with the remote control con- RX1 sole. Potentiometers P1- P14 Test channel adjustment of A/D converter, potentiometers are secured with sealer and must not be readjusted. Reset Button PL1 Pressing Reset button PL1 resets the CPU board, but does not necessarily reset the remote console. Entire system reset only if system is turned “off” and “on” again. Relays RL1 Watchdog relay ‘SPC connector Service PC connection Siemens AG Register? FRDS.ZOGOH.O Page 30 0f42 SIREGRAPH OF Medical Engineering Rev.03 12.98 qorc2t 1-40 Overview Overview of microswitches VO board 2482 Awa No~? L58 | IN.10 3FC1 15 5 IL NOL © es | IN.18 3FC2 12 6 {NOs ©Le7 | IN.19 3FC3 "1 | IN.20 “Cs 10 3FC4 4 UNO IN.B 16 3FC5 e 2 dL Nox L62| IN.14 14 3FC8 44 NOx ©v61] IN.13 3FC9 13 Se? | No us7| INS 3x82 SREGRAPH GF Regier AXDSDDADITLDT Page AU oT@ STemane AG Rev.03 12.98 TDTc21 Medical Engineering Overview 1-41 ‘Switch 3P1 3FC1 3FC2 3FC3 3FC4 3FCS 3FC7 3FC8 3FC9 3x82 SFC12 3FC14 3FC15 LED24 function (switch actuated = LED "on") s2 L58gn Le6gn Le7gn Leagn Ls6gn L62gn L61gn 157g Emergency Stop switch on remote control console. Refer to page 4-4, Safety circuit, in the Function Description. 0° tube rotation (tube centered on |... Refer to function descriptions of: ~ Multleaf collimator, page 6-9. - Collimator blade 7rive, page 7-9. - Grid drive, page 7-19 ~ Cassette carriage control, page 7-27. Cone in park position. Refer to function description of compression movement , page 5-6. Cone inserted. Refer to function description of compres- sion movement, page 5-6. Cone pressure >50N. Refer to function description of, compression movement, page 5-6. Collision protection counterbalance. Refer to function descriptions of: ~ Swivel angle movement, page 4-24 - column drive mechanical components, page 4-19 SID safety limit switch. Refer to function descriptions of: - SID drive, page 5-11 ~ Safety circuit, page 4-4. Transverse table limit stop on "wall side”. Refer to Func- tion Description, Transverse table drive, page 5-19. Transverse table limit stop on “physician side”. Refer to Function Description, Transverse table drive, page 5-19. Systems A and B: "Grid contact”, induction switch XS2 actuated. Systems C and D: high-line grid in the beam path."OFF": High-line grid manually removed (optional for systems C and D). Refer to Function Description, Grid control, page 7-19. Safety limit switch, “column”, Refer to Function Descriptions for: ~ Longitudinal carriage travel electronics, page 4-17. ~ Swivel angle movement electronics, page 4-25. + Safety circuit, page 4-4. Safety limit switch, “spottilm device” Refer to Function Description, Swivel movement elec- tronics, page 4-25. Safety circuit, page 4-4. Safety limit switch, swivel angle >40°. Refer to Function Description, Safety circuit, page 4-4 Siemens AG Medical Engineering Rogistor7 FXOG-209.041.07 Page 41 of 42 SIREGRAPH CF Rev.03 12.98 TDTc21 1-42 Overview This page intentionally left blank. ‘SIREGRAPH OF Rogistor7 FXOS-209.001.07 Page 42 of 42 ‘Siamens AG Rev.03 12.98 ToTC21 Medical Engineering Power Supply 2-1 Table of contents Chapter 2 Primary Power Supply Page 2-2 Explanation of terms. Page 2-2 Power Transformer 22TR1 Connections Page 2-3 Fuses Page 2-3 Transformer 22TR2 Connections Page 2-4 Fuses Page 2-4 Voltage Distribution Transformer 22TR1 Page 2-5 Voltage Distribution Transformer 22TR2 Page 2-6 Siemens AG Medical Engineering Rogistor7 FXOG-209.041.07 Rev.03 12.98 Page 1of6 TDTc21 SIREGRAPH CF Power Supply Primary Power Supply 217TB1 «211A1 = 24L4. -21K1—-21K2 FS 22TR1 Explanation of Terms Connector Block 21TB1 Connector block 21TA1 3-phase overload circuit breaker 21K1 Safety contactor 21K2 System contactor, switch-on attenuation 21TR1 Power transformer 21TR2 Low voltage transformer F1-F7 Line fuses SIREGRAPH GF Register? RXOS-208.081.07 Page 2086 ‘Siemens AG Rev.03 12.98 TDTc21 Medical Engineering Power Supply 2-3 Power Transformer 22TR1 Connections 230Vac Injector, IDEOMED DI F2 j230Vac Injector F341 05Vac Fan tube hous. | Fao 105Vac Fan tube hous. | F29 ——— WOVac Mit drive F28 4 2a0Vac Titdrive | Fo7 MP ——— F2 |[208Vac Primary Voltage 240Vac Tilt di F26 eS F3|208Vac Primary Voltage rac Spotfilm dev. | pos > F4 [208Vac Primary Voltage 106Vac Spotfilm dev. | F24 ee =| F5 [400Vac Primary Voltage 105Vac Spotfilm dev. | F23 ~— Fe |[400Vac Primary Voltage TosVac Column | Foo F7 [400Vac Primary Voltage 705Vac Column | F24 a Fa [440Vac Primary Voltage 705Vac Column | F29 —— F9 | 440Vac Primary Voltage] 4iVac Backplane | p49 > ‘440Vac Pri y Volt | Fivac Backplane] p1g F10 ac Primat oltage! > F411 | 480Vac Primary Voltage| 41Vac Backplane Fi7 —— a — Fiz | 480Vac Primary Voltage| F5Vac Cass. carriage | pig F1g_ | 480Vac Primary Voltagd [AbVac Cass. carmage | p45 — GND | Shielding Vac Cass. carriage | 14 ———sa Fuses F2-F4 16A slow-blow FI7-F19 6A slow-blow F5-F7 8A slow-blow F20 - F25 10A slow-blow F8-F13 6A slow-blow F26 - F28 6A slow-blow F14-F16 4A slow-blow F29 - F30 1A fast-blow F31 - F32 6.3A slow-blow Siemens AG Register? FRDS.ZOGOH.O Page 3075 SIREGRAPH OF Medical Engineering Rev.03 12.98 yore 2 2-4 Power Supply Transformer 22TR2 Connections 25V Rotary cradle F150 FA ov 24V Light localizer F15, a — | F2 f08Vac Primary Voltage OV Light localizer F416 = ——-s F3 00Vac Primary Voltage OV WO-board 2452 | F147 I F4 }40Vac Primary Voltage Ziv W0- board 2482 | F4g = > F5 [80Vac Primary Voltage OV Mini drives 23510 | F49 —— -=> Collimator 2453 6 TEV Mini drives 23510 | ro9 19V Supply Processor ~Collimator 2453 1 OV Mini drives 23510 roy OV Supply Processor —SCollimator 2453) TBV Mini drives 23510] roo 8 | 18V Supply Processor = _Collimator 2483] 9 lovsuppy Pp T6V Remote control desk] ro3 upply Processor 10 OV Remote control desk | oq ‘16V Supply Processor "1 TeV Remote control desk| Fog ov Supply Processor — 12 OV Remote control desk] rag 10V Supply Processor 13 | oV Supply Processor 14 | Shielding Fuses FA F2 4A* F17, F18 6.3A* F3 2.5A* F19,F20 8A* F5,F5 2A" F21, F22 BA* F15, F16 6.3A* F23, F26 1.6A* * slow-blow SIREGRAPH CF Register 7 ARDS2OGOH.O Page 40f6 Siemens AG Rev.03- 12.98 ror 21 Mecical Engineesing Power Supply 2-5 Voltage Distribution Transformer 22TR1 22TR1 Lt 5 FS8A F28 _.,22k1.5 Contactor tilt upright Ee 22K2.5 Contactor tilt down F27 22K1.3 Contactor tilt upright I 240V © 22K2.3 Contactor tilt down F26 __ 22K1.1 Contactor tilt upright L Baov 22K2.1 Contactor tilt down Spotfilm device Ll ‘08v Controller board © 22AZ4.23 L pa © 2224.22 F6 8A 0 22AZ4.21 126 LT 105V Column 108N Controller board 10 22AZ3.23 05VF21 o22Az3.22 £29 tO 22AZ3,21 Ti ~ 22810 22RD Backplane| KF Vena lz2az2 ~ 97 p 134mg L370 8 r yes | bk | gous F46 Cassette rr Gp IS6M2G— coriage adv I E19 aro Sct aed LS SAz5- o—7230z8 e aiveis | 7 L fasst0 7? Backplane| bow 412 Diaphragm i Vv plates 1 Table transv. Compression SID Siemens AG Medical Engineering Rogistor7 Rev, FXOG-209.041.07 Page 506 SIREGRAPH GF 03 12.98 TDTC21 2-6 Power Supply Voltage Distribution Transformer 22TR2 CPU board 2481 22TR2 CNS F13,150, 13/4 u tov 12 [3 F3 ——! “(2 oD 16V 10 (1 F4 F2.3,15A oS 9 |s 208 o tov 8 |7 FS pS 7 |6 F3 2A l23 19V 6 (5 F4 4001 ——$ 3 F42A SC1 Collimator control Fis 15 [6 board 2483 Atov 24Ve1g 16 |5{X{ Light localizer F528 Io, F418 480v SC1.4 V0 board 2482 24V, E17 ov SC1.1 0 board 2482 F290 —([Sc2 sci Tel T° 223810 Collimator E19 —|, ,Backplane {—P 1 control ov Mini drives board F22 22483 eV E24 3 ov 4 4 aus cN6 182 F2 4 Remote control HeVeo3 3 ; desk OV F262 Hav 2 F254 ov pt SIREGRAPH CF Register 7 ARDS2OGOH.O Page 6oF6 Siemens AG Rev.03 12.98 TDTC21 Medical Engineering Remote Control Console 3-1 Table of contents Chapter 3 Remote Control Console Board Layout Page 3-2 Control Panel Board 181 Page 3-2 Connections Page 3-2 Processor Board 182 Page 3-3 Connections Page 3-3 LED's Page 3-3 Programming Switch Page 3- 4 Potentiometer Page 3-4 Buttons Page 3- 4 Fuses Page 3-4 Remote Control Console Connections Page 3-5 Siemens AG Fogiter7 FXDS2OGDUT.OT Pago 1oF8 SIREGRAPH CF Medical Engineering Rev.03 12.98 TDTc21 3-2 Remote Control Console Remote Control Console Board Layout Control Pane! Board 181 181 Cd © csc CP3 cP4 cp2-——J cp 0 Rear side M1 cl cece cFc3_ CFC4 [ ] LN Connections CFC1 Switch signals. CFC2 Display drive signals. CFC3 LED drive signals. CFC4 LED drive signals. CP1 Emergency Stop button. CP2 Control signal, control switch P48 ist level, series contact VK 2nd level, main contact HK. CP3 Control signal connection P40A-D Collimator coordinate switch (contact switch), P41 compression, P42 tilt, P43 swivel angle. CP4 _Potentiometer connection P44A-D variable speed selection for lon- gitudinal carriage, P44 B,C transverse table drive. CP5 same as CP2. M1 Interface board connection 22S1 KK Interface. ‘SIREGRAPH GF Register? AXDSOSON.OT Page 2086 Siemens AG Rev.03 12.98 TDTc21 Medical Engineering Remote Control Console 3-3 Processor board 182 cN4 PL1 e@ Ls CNS CNT cNn2 BB RXi> J1 J2 Tx1> cnt Ne 6 E. F2 e000 er Uo u-w ls Connections cNt Control signal switches. CN2 Display drive signals. CN3 LED drive signals. cN4 LED drive signals. CNS Joystick control signals. NE Power supply CN7 no function. RX1/TX1 Fiber optic cables, communication with CPU board 2481 in the electronics cabinet. LED's Lign Series contact VK. L2gn Main contact HK. L3gn _—notused. Lagn Fluoroscopy. L5rt Remote control console malfunction, error. Siemens AG Register? ARDSDOGON.OT Pago S076 SIREGRAPH CF Medical Engineering Rev.03 12.98 rice: 3-4 Remote Control Console Programming switch a ON 2 OFF Potentiometer Pt Power supply adjustment. Button PLI Reset button Fuses Fi 1.6A* 16Vac Power supply. F2 1.6A* 10Vac Power supply. * slow-blow ‘SIREGRAPH GF Register 7 AXDSOSON.OT Pago sof6 Siemens AG Rev.03 12.98 TDTc21 Medical Engineering Remote Control Console Remote Control Console Connection 181 Key pad fm pis |cr1 —1_ Control signals p40A- P43B\cp3 —~_| P44- P45B|CPS pb 182 Processor board 1x cna] |crc1 Fiber optics connection [_] to CPU board 2481 7 Keys — Display » cn3|_|crc3 F241,64 |CN64 LEDs » ms F251,6A |cNe1 F1 CN4)_ | CFC4 io: j— » F264,6A |cN62 —\o » Direction of signal flux Siemens AG Rogistor7 FXOG-209.041.07 Page 506 Medical Engineering Rev.03 12.98 TDTC21 SIREGRAPH CF 3-6 Remote Control Console Potentiometer P44A-D is mechanically coupled with joystick P44 for longitu- dinal carriage travel and transverse table travel. Depending on the deflection of the joystick, a variable nominal speed value for the longitudinal carriage or transverse table movement is selected. The voltage value of potentiometer P4A-D, which is directly proportional to the speed selected, is forwarded to the "remote control console” processor board 182 via the keyboard 181 On board 182, the voltage values of potentiometer PA4A-D “longitudinal car- riage" and "table - transverse movement” are converted from analog to digi- tal signals. The control switch signals of P16 connector CP1, P40A- P43B connector CP3, P44 - PA5B connector CP5, P44 B-C connector CP4 are transmitted from the keyboard PCB 1S1 via connector CFC1 - CN1 to "remote control console” processor board 182. Processor board 1$2 transmits the control signals and the A/D converted values via fiber optic cable to CPU board 2481 in the electronics cabinet. CPU board 2481 drives the tomographic height display, the number of expo- sures left (connector CN3 - CFC2) and the LED's in control switches and in the remote control console (connector CN2-CFC3 and CN7-CFC4) via fiber optic cable, processor board 182 “remote control console” and keyboard PCB1S1 ‘SIREGRAPH OF Rogistor7 FXOS-209.001.07 Page 606 ‘Siamens AG Rev.03 12.98 TDTC21 Medical Engineering Motor drives of the basic system 4-1 Table of contents chapter 4 Speed control board for 22AZ3 column and 22AZ4 spotfilm Page 4-2 device Connections Page 4-2 Potentiometers on the plug-in board Page 4-2 LED's Page 4-2 Variable resistor RT Page 4-3 Programming switch SW1 Page 4-3 Plug-in board Page 4-3 Safety circuit Page 4-4 Safety limit switch in the safety circuit Page 4-5 Safety limit switch in the motor circuit Page 4-5 Main drive mechanical systems. Page 4-6 Tilt drive Page 4-6 Column drive Page 4-8 Spottilm device drive Page 4-10 Tilt drive electronics: Page 4-12 Blocking (Disabling) Functions Page 4-13 Activation Page 4-15 Longitudinal carriage travel electronics Page 4-16 Blocking (Disabling) Functions Page 4-17 Activation Page 4-19 ‘Speed regulation Page 4-21 Tube angulation electronics Page 4-24 Blocking (Disabling) Functions Page 4-25 Activation Page 4-27 ‘Speed control Page 4-29 Tomographic height Page 4-31 Tomo sweep electronics Page 4-34 Blocking (Disabling) Functions Page 4-35 Tomo sweep Page 4-37 Activation Page 4-37 ‘Speed control Page 4-41 Tomography Page 4-43 Somers AG Regu AXDSZOGDELOT Page Tora SREGRAPA GF Medical Engineering Rev.03 12.98 TDTc21 Motor drives of the basic system Speed control board for 22AZ3 column and 22AZ4 spotfilm device ci C2 Plugin board: RT. Co Swi Boon 09.09. Pao. PS | L113 QUUUD_|bbd Refer to the Function Description Long. carriage travel electronics Page 4-16. Tube angulation electronics Page 4-24. ‘Tomo height electronics Page 4-31 Tomo sweep electronics Page 4-35 Connections C1 Input / output signals C2 Power supply Potentiometers on the plug-in board Notice: Adjustments are described in the adjustment instructions, P1 0: offset adjustment. P2 Maximum speed (+20% to -50%). P3 Derivative action adjustment (PID pot). P4 — Runup ramp (soft start) P5 Proportional action adjustment (PID pot). LED's 1rt_ The maximum current of 14 A was exceeded for more than 2 sec- onds. The current is now limited to 14 A. Normally "off L2rt Generator has functional defect or is incorrectly connected (during travel) Normally L3gn Power supply (3-phase) present. Normally “on”. SIREGRAPH GF Register? RXOS-208.081.07 Page 20144 ‘Siemens AG Rev.03 12.98 TDTc21 Medical Engineering Motor drives of the basic system 4-3 Variable resistor RT Due to the different speeds of motors 3MT1 "column", motor control 22AZ3 and 3MT2 "spotfilm device", motor control 22AZ4, resistor RT must be sol- dered to the corresponding drive. When board 22AZ3 or board 22AZ4 are replaced, the plug-in board must be transferred with the potentiometers. Programming switch swi i SW1-1/2 ON Control with generator OFF Control via motor current SW1-3. ON with safety circuit for generator OFF without safety circuit for generator SW1-4 ON without runup ramp OFF with runup ramp Normal setting: SW1-1/2 ON swi-3 OFF swi-4 ON Plug-in board RT Siemens AG Register? RXOS-208.041.07 Page 30144 SIREGRAPH GF Medical Engineering Rev.03 12.98 TDTC21 Motor drives of the basic system Safety circuit +24V KK Interface board 2281 $C1.5 22S8C3. 4 NC 3P1 Emergency stop spotfilm device 3FC15 ‘Swivel angle > 4/- 40° 3FC16 LL. collision protection OO Fo Fo CPU board 2481 RL1 watchdog 3FC13 fo Sliding bow switch on column $C1.4 217 $C1.3 21T B21 NC B2.2 3FC11 Tilt drive Zo CM1.11 CM1. Emergency stop Remote control console Hi Oo 21K1 Safety contactor ‘SIREGRAPH OF Rogistor7 FXOS-209.001.07 Rev, 03 ‘Siamens AG Medical Engineering Page 4 of 44 12.98 TDTc21 Motor drives of the basic system 4-5 Satety limit switch in the safety circuit 3FC11 Safety limit switch tilt drive, activated at -20° / + 91° tit angle. 3FC13_ Safety limit switch for SID Telescope (slide switch). 3FC15 Safety limit switch for swivel angle, activated at +/- 41°. 3FC16 = Safety limit switch for |.I. collision protection. 3P1 Emergency stop switch / Remote control console. Safety limit switches Safety limit switches for the “column” 3FC12 and for "spotfilm device” jn the motor circuit 3FC14 travel switch only those respective movements off when actuated. The armature is shorted via a resistor. The drive can only be moved manually out of this position. Control board C) 3mr4 22AZ3 "Column" Column Control board Cy sur2 22AZ4" il Spotfilm device Siemans AG Regier ARDS ZDGDILOT Pag Sofa SREGRAPH GF Medical Engineering Rev.03 12.98 TDTC21 4-6 Motor drives of the basic system Main drive mechanical systems Tit drive Spottilm device Hl Column (els) o Flying wheel ~~ il HE d a) \ =a \,Strainig screw / Potentiometer 3PT4 / Brass plate Poly- V- belt Permanent brake SIREGRAPH CF Register 7 ANDSZOGON.OT Page Sofa Siemens AG Rev.03 12.98 TDTC21 Medical Engineering Motor drives of the basic system 4-7 Tilt drive motor 3MT4 is attached to a brass plate. The plate can be mechan- ically shifted in the vertical direction via four elongated slots. The motor and gear box are mechanically connected via a poly-V-belt. A straining screw makes it possible to slide the motor block on the brass plate to tighten the poly-V-bett. ‘The gear box with pinion drives the toothed segment of the tilt drive. The toothed segment is covered by a plastic tape The permanent brake for the tilt drive is located on the gear box shaft. If the poly-V-belt malfunctions, the brake stops the drive. if travel exceeds the end positions of +90° “upright” and -18° "Trendelen- burg," safety limit switch 3FC11 is activated by switch cams at +91° or - 19° and safety contactor 22K1 deenergizes. if the collision protection on the |.I. touches the floor, microswitch 3FC16 is actuated and safety contactor 22K1 deenergizes. Refer to Safety circult on page 4-5 of the Function Description. Actual value potentiometer 3PT4 on the tit drive acquires the position of tit travel. Itis attached to the drive via a brass plate and mechanically coupled to the tilt drive via a toothed gearwheel ‘The brake for the tilt drive releases as soon as voltage is present for tit travel (lifting up oF titing down). Siemens AG Medical Engineering Rogistor7 FXOG-209.041.07 Page 7 of 44 SIREGRAPH CF Rev.03 12.98 TDTC21 4-8 Motor drives of the basic system Column ative a £ Oo & a s % > 2 Ell £ = Oo rare 0 05) 5 ( < 5 2 ce wf EF as Zo fe 53 O8 62 < E So 5 i 8 5 a £ = 2 3 = 6 ‘SIREGRAPH OF Rogistor7 FXOS-209.001.07 Page 8 of 44 ‘Siamens AG Rev.03 12.98 TDTc21 Medical Engineering Motor drives of the basic system 4-9 Column motor drive 3MT1 and gear box is installed in an upright position inside the column. The drive pinion runs in a toothed rack which is attached to the carriage profile at the top with screws. Located on both ends are switch cams which actuate microswitches if the maximum position is exceeded at the head or foot end of the column: * Safety limit switch 3FC12 “column”. Refer to Safety circuit on page 4-4ot the Function Description. * Disable switch 3FCS, if: ~ The tube is swiveled toward the head or foot end and the longitudinal carriage stops moving just in front of the end position. Swivel movement is blocked in one direction when microswitch 3FCS is actuated. ~ The tube is swiveled toward the head or foot end and the longitudinal carriage is moved towards the end position. The movement of the longitudinal carriage is blocked in one direction when microswitch 3FC5 is actuated. Microswitch 3FC5 prevents the somewhat wider counterbalance carriage for the spotfilm device from colliding with the end position. Generator 3DT1 is integrated in motor 3MT1. During travel, it emits an ana- log voltage that is directly proportional to the actual speed of the column drive. Potentiometer 3PT1 acquires the actual position. It is mechanically coupled to motor 3MT1 via a toothed gearwheel. The “column” and the “spotfilm device" travel are synchronized and speed regulated to enable the following travel using only two drives: Long. ‘Synchronous travel of the column 3MT1 and spottilm device carriage: 3MT2 in the same direction. Swiveling Synchronous travel of the column 3MT1 and spottilm device 3MT2 in opposite directions. At the same time, distance, starting position and end position as well as the speed of the spotfilm device during travel are dependent on the tomographic height selected, Tomo- Synchronous column 3MT1 and spottilm device 3MT2 travel in graphy —_ opposite directions. At the same time, distance, starting posi- tion and end position as well as speed of the spottilm device during travel are dependent on the tomographic height selected. Refer to Tomographic height on page 4-31 of the Function Description Siemens AG Rogistor7 FXOG-209.041.07 Page 9 of 44 SIREGRAPH CF Medical Engineering Rev.03 12.98 TDTC21 Motor drives of the basic system 4-10 Spottilm device drive wes Bulyo}mg cLae CLINE ‘Siamens AG Medical Engineering Page 10 of 4& TDTc21 FXOS-209.001.07 Rogistor7 ‘SIREGRAPH OF 12.98 Rev, 03 Motor drives of the basic system 4-11 The spotfilm device motor drive 3MT2 and gear box is positioned horizon- tally inside the spotfilm device. The drive pinion runs along a toothed rack that is attached to the bottom of the carriage profile with screws, Located at both ends of the toothed rack are switch cams which actuate the "spotfilm” device" 3FC14 safety limit switch whenever the maximum position is exceeded at the head or foot end. Refer to Safety circuit, page 4-5 of the Function Description: “Spotfilm device" generator 3DT2 is an integral component of motor block ‘3MT2, and must be replaced with the motor. During travel, it generates an analog voltage that is directly proportional to the actual speed of the spottilm device. Potentiometer 3PT2 is mechanically coupled via a toothed gearwheel with motor 3MT2. The voltage value is directly proportional to the position of the spottilm device. The “swivel angle” safety limit switch 3FC15 is actuated by a switch cam if the system exceeds the maximum swivel angle of +/- 41°. Safety contactor 22K1 is deenergized. Refer to Safety circuit, page 4- 5 of the Function Description. The “column” and "spotfilm device" travel are synchronized and speed-regu- lated. The speeds for tube angulation and tomography are defined by the software. This allows the following movements to be performed with only two drives: Long. Synchronous travel of the “column” 3MT1 and “spottilm carriage: _device" 3MT2 in the same direction. Swivel ‘Synchronous travel of the “column” 3MT1 and “spottilm device” 3MT2 in opposite directions. At the same time, the distance, starting position and end position as well as the speed of the spotfilm device during travel are dependent on the tomographic height selected. ‘Tomography: Synchronous travel of the “column” 3MT1 and "spottilm device” 3MT2 in opposite directions. At the same time, the distance, starting position and end position as well as the speed of the spottilm device during travel are dependent on the tomographic height selected, Refer to Tomographic Height in the Function Description, page 4-31 Siemens AG Rogistor7 FXOG-209.041.07 Page 11 of a4 SIREGRAPH CF Medical Engineering Rev.03 12.98 TDTC21 4-12 Motor drives of the basic system Tilt drive electronics 381 Tableside control panel AMP1 WO board 2482 CPU board 2481 Jamp2 wa an ae 00000000¢N7)) ,,|CNZ 00000000 00000000, | gcz 0000000 cng, ‘CNG 00000000, j a E 8 88 | TP2|, PA cP18 8 Bens CNS mms 8 8 pwi8 8 8 8 8 8 8 8 gcn4a CN4 190 6 g 8 E TP1i L941 FOC@ Emergency Stop anp8 op0dg| 000 o jp [BB68, .geee| Bees Son Remote control console plooMou| o Oo x 22K2 «22K1 F26 22TR1 21 4 3PT4 x F27240 V| ott a F29240|V ete as 240] 5s SREGRAPACF Rega AXDSZDSDETLOT Page 12 ota Somers AG Rev.03 12.98 TDTc21 Medical Engineering Motor drives of the basic system 4-13 Blocking (disabling) ~ Satety circuit responded, safety contactor 21K1 deenergized. Refer to functions Function Description: Safety circult, page 4-7. - Programmed room height exceeded, programming by service switch DW1 on I/O- board 2482. Service switch DW1 can be used to program any of the following room heights: Room height > 327cm max. 300cm max. 285cm max. 260cm ON fo oooO (}aio}o\o}0/00) (alojojojojojo[0) Ojo}o}o}o/o}0 0) OFF (ojoloio|ojooln) lalojolo(o{ofoo) [olalolo|o}olo|dy lata) c1o[0|o)o}0) 260cm Dwi-1 OFF Dwt-2 OFF 285em pwi-1 ON Dwi-2 OFF 300cm Dwi-1 OFF Dwi-2 ON 327em Dwi-1 ON Dwt-2 ON Starting with software version VCO1A (for Gorla collimators only), Dip switches DW1.1 and DW1.2 on /O- board 24S2 have no function. ‘The room height can now be programmed using codes 201 to 209 in 10m increments from 260em to 340cm in adjustment mode. ~ Ifthe tube cover comes closer than Sem to the programmed room height limit during travel (e.g. SID is >115em and the tube swivels toward the head-end while the longitudinal carriage travels headward), upright travel stops when the minimum distance is reached. - End position reached Actual value potentiometer 3PT4 for acquiring the tilt position is mechanically coupled with the tilt movement. When the system reaches the end positions of +90° or -18°, tilt movement is automatically blocked. Actual value potentiometer 3PT4 is connected to plug CP1 of /0 board. 2482. The actual value acquired for the tlt drive position is applied at test point TP2 on CPU board 24S1 Test points: TP2.1 _Uact Tilt drive, analog voltage IN. TP2-13 OV Analog voltage IN ~ SID not 115cm, 135cm or 150cm. LED's in the SID switches flash, if the SID of 115m, 135¢m or 150cm has not been reached. All basic ut movements are disabled. The SID switches are designed as deadman switches. The button must be actuated until the selected position is reached (until the LED in the button lights up). Siemens AG Rogistor7 FXOG-209.041.07 Page 15 of 44 SIREGRAPH CF Medical Engineering Rev.03 12.98 TDTc21 4-14 Motor drives of the basic system Tableside control panel AMP1 P42A P42B nonooadonPo Oo VO board 2482 CPU board 2481 JAMP2 L211 ee oooonhes. cE | Gopo 866g) con : o|fope soos] oc Remote control 182 console ole OOF 5 5: | oo ° | o a i x 22K2 22K1,4, 22TR1 21K1 — 11 3PT4 F27240 V| ott F28240/V] oot? 240|V oo t3 SREGRAPACF Regan AXDSZOSDETLOT Page 4 oT Somers AG Rev.03 12.98 TDTc21 Medical Engineering

You might also like