You are on page 1of 4

Report Author: THE CADWORLD

Date: 12 Fab 2024

Tank 264

Organization: Santo Engineering Pvt Ltd Part name: Tank


Operator: Vipul Sharma Part #: 264
E-mail: karan@cadworld.in Drawing # : Tank_264
Workspace: Santo Engg. Serial #:

Project: Tank 264 Device: Faro Edge


Organization: Santo Engineering Pvt Ltd Part name: Tank
Operator: Vipul Sharma Part number: 264
E-mail: karan@cadworld.in Piece: Faro edge
Feature Table
Length Units Millimeters
Coordinate Systems world
Data Alignments plane, axis, center point 1

67.T2
Control Nom Meas Tol Dev Test Out Tol
2.000 1.999 2.000 1.999 Pass

21.T2
Control Nom Meas Tol Dev Test Out Tol
X Distance 2600.000 2599.763 ±2.000 -0.237 Pass

22.T2
Control Nom Meas Tol Dev Test Out Tol
X Distance 2600.000 2600.764 ±2.000 0.764 Pass

24.T2
Control Nom Meas Tol Dev Test Out Tol
Y Distance 1602.000 1603.065 ±2.000 1.065 Pass

23.T2
Control Nom Meas Tol Dev Test Out Tol
Y Distance 1602.000 1603.652 ±2.000 1.652 Pass

25.T2
Control Nom Meas Tol Dev Test Out Tol
3D Distance 3054.000 3053.887 ±3.000 -0.113 Pass

26.T2
Control Nom Meas Tol Dev Test Out Tol
3D Distance 3054.000 3055.644 ±3.000 1.644 Pass

36.T3
Control Nom Meas Tol Dev Test Out Tol
X Distance 353.000 354.458 ±2.000 1.458 Pass

31.T3
Control Nom Meas Tol Dev Test Out Tol
X Distance 353.000 354.325 ±2.000 1.325 Pass

44.T3
Control Nom Meas Tol Dev Test Out Tol
Y Distance 138.000 138.724 ±2.000 0.724 Pass

Organization: Santo Engineering Pvt Ltd Part name: Tank


Operator: Vipul Sharma Part number: 264
E-mail: karan@cadworld.in Piece: Faro edge
41.T3
Control Nom Meas Tol Dev Test Out Tol
Y Distance 138.000 138.457 ±2.000 0.457 Pass

38.T3
Control Nom Meas Tol Dev Test Out Tol
Y Distance 197.000 198.487 ±2.000 1.487 Pass

33.T3
Control Nom Meas Tol Dev Test Out Tol
Y Distance 197.000 198.547 ±2.000 1.547 Pass

37.T3
Control Nom Meas Tol Dev Test Out Tol
Z Distance 290.000 291.846 ±2.000 1.846 Pass

32.T3
Control Nom Meas Tol Dev Test Out Tol
Z Distance 290.000 291.768 ±2.000 1.768 Pass

42.T3
Control Nom Meas Tol Dev Test Out Tol
Z Distance 371.500 370.270 ±2.000 -1.230 Pass

45.T3
Control Nom Meas Tol Dev Test Out Tol
Z Distance 371.500 369.690 ±2.000 -1.810 Pass

46.T3
Control Nom Meas Tol Dev Test Out Tol
X Distance 1037.500 1038.346 ±2.000 0.846 Pass

43.T3
Control Nom Meas Tol Dev Test Out Tol
X Distance 1037.500 1038.345 ±2.000 0.845 Pass

51.T5
Control Nom Meas Tol Dev Test Out Tol
X Distance 80.000 79.678 ±2.000 -0.322 Pass

52.T5
Control Nom Meas Tol Dev Test Out Tol
X Distance 200.000 199.091 ±2.000 -0.909 Pass

Organization: Santo Engineering Pvt Ltd Part name: Tank


Operator: Vipul Sharma Part number: 264
E-mail: karan@cadworld.in Piece: Faro edge

You might also like