Runoff Analysis Input Data Processing Form

Developing Hourly Rainfall Hyetograph by Alternating Block Method

Basic Information : River Basin Name SIBUGUEY RIVER


Catchment Area (km ) * 2
800.25
* : Catchment area of the total of all sub-basins

After filling two yellow cells above, then go to sheet "02Method".

Notes :

- This form helps users to develop hourly rainfall hyetographs by the Alternating Block
Method .

- Black ltr. and Blue ltr. Yellow cells: Requiring manual input.

- Black ltr. and Blue ltr. Clear cells: Automatically filled.

- Values in Blue ltr. and Blue ltr. should be utilized as inputs for
the runoff analysis with HEC-HMS.
- Black ltr. Shaded cells: Descriptions only.
Information in these cells are not used for computations.

References :

1 RIDF of Selected Synoptic PAGASA Station, Attachment 4.3 of "Specific Discharge Curve,
Rainfall Intensity Duration Curve, Isohyet of Probable 1-day Rainfall", FCSEC, March 2003

2 Iso-specific Coefficient, Attachment 4.4 of "Specific Discharge Curve, Rainfall Intensity


Duration Curve, Isohyet of Probable 1-day Rainfall", FCSEC, March 2003

3 Isohyet of Probable 1-Day Rainfall, Attachment 4.5 of "Specific Discharge Curve, Rainfall
Intensity Duration Curve, Isohyet of Probable 1-day Rainfall", FCSEC, March 2003
01StList

Runoff Analysis Input Data Processing Form

Developing Hourly Rainfall Hyetograph by Alternating Block Method


This work worksheet requires no data
input by users.
1. List of PAGASA Synoptic Station Having FCSEC's RDIF Curve
(RDIF curves are presented in Reference 1)
No. Sta. ID Station Region
1 222 Vigan Ilocos Sur
2 223 Laoag Ilocos Norte
3 232 Aparri Cagayan
4 233 Tuguegarao Cagayan
5 324 Iba Zambales
6 325 Dagupan City Pangasinan
7 328 Baguio City Benguet
8 330 Cabanatuan Nueva Ecija
9 333 Baler Quezon
10 425 Port Area Manila
11 427 Tayabas Quezon
12 429 NAIA (MIA) Pasay City
13 430 Science Garden Quezon City
14 432 Ambulong Batangas
15 434 Infanta Quezon
16 435 Alabat Quezon
17 440 Daet Camarines Norte
18 444 Legaspi City Albay
19 446 Virac Rader Catanduanes
20 526 Coron Palawan
21 531 San Jose Occidental Mindoro
22 536 Romblon Romblon
23 538 Roxas City Aklan
24 543 Masbate Masbate
25 546 Catarman Northern Samar
26 548 Catbalogan Western Samar
27 550 Tacloban City Layte
28 558 Guiuan Eastern Samar
29 618 Puerto Prinsesa Palawan
30 630 Cuyo Palawan
31 637 Iloilo City Iloilo
32 642 Dumaguete City Negros Oriental
33 644 Tagbilaran Boholl
34 646 Mactan International Airport Cebu
35 648 Maasin Southern Layte
36 653 Surigao Surigao del Norte
37 741 Dipolog Zamboanga del Norte
38 748 Cagayan de Oro Misamis Oriental
39 751 Malaybalay Bukidnon
40 753 Davao City Davao del Sur
41 755 Hinatuan Surigao del Sur
42 826 Zamboanga City Zamboanga del Sur
43 851 General Santos
02Methods

Runoff Analysis Input Data Processing Form

Developing Hourly Rainfall Hyetograph by Alternating Block Method

2. Coefficients for Rainfall Intensity-Duration-Frequency (RIDF) Curve


(1) Selection of Methods : Selection is OK.

Tick with "x" one of four methods accorting to your selection.

X Method 1: Apply FCSEC's RIDF curves at one of PAGASA synoptic stations on sheet "01StList"
Method 2: Manual input of coefficients for RDIF curves

Method 3: Develop RIDF curves based on iso-specific coefficient and isohyet of probable 1-day rain

Method 4: Manual input of hourly rainfall values (Go to Sheet "04Method4")

(2-1) Method 1 : Apply FCSEC's RIDF curves at a PAGASA synoptic station


This method is selected now.
* : Select one station ID from the table on sheet "01StList"
PAGASA Synoptic Station Station ID* 741 Name Dipolog

Coefficients for RIDF Curves (from Reference 1)


Return Short Duration (10min - 1hr)** Long Duration (1hr - 24 hr) Formula
Period
(Year) Type A C b Type A C b T (min)
2 2 1892.64 20.92 0.82 2 4471.45 14.83 0.92 Type 1 :
5 1 2976.48 13.49 0.82 2 7333.60 6.41 0.96 A
R=
10 1 3037.13 11.70 0.79 2 10115.33 6.09 0.98 ( C +T b )
25 1 3146.08 10.24 0.76 2 13013.41 6.09 0.99 Type 2 :
50 1 3225.29 9.44 0.74 2 12494.34 6.09 0.98 A
R=
100 1 3299.34 8.79 0.73 2 14708.26 6.09 0.99 ( C+ T )b
** : Short duration curves are not applicable to this form.

(2-2) Method 2 : Manual input of coefficients for RIDF curves


This method is NOT selected now.
Coefficients for RIDF Curves (Manual Input)
Return Short Duration (10min - 1hr)** Long Duration (1hr - 24 hr) Formula
Period
(Year) Type A C b Type A C b T (min)
2 2 4471.45 14.83 0.92 Type 1 :
Short duration curves are not
5 applicable to this form. 2 7333.60 6.41 0.96 A
R=
10 2 10115.33 6.09 0.98 ( C +T b )
25 2 13013.41 6.09 0.99 Type 2 :
50 2 12494.34 6.09 0.98 A
R=
100 2 14708.26 6.09 0.99 ( C+ T )b

(2-3) Method 3 : Iso-specific Coefficient and Isohyeto of Probable 1-day Rainfall


This method is NOT selected now.
Location Interested Batangas
Specific Coefficient b (from Reference 2) 7.3 b (=log b/(log24-log1)) 0.626
Probable 1-day Rainfall Return Period (Year) 2 5 10 25 50 100
(from Reference 3) R (mm) 155 230 270 330 365 400
1-day Rainfall Intensity Return Period (Year) 2 5 10 25 50 100
I24 = R/24 I24 (mm/hr) 6.458 9.583 11.250 13.750 15.208 16.667

( ) ( )
b b
Rainfall Intensity for 24 24 R
I t= ×I 24= ×
Duration t (hours) It (mm/hr) t t 24
Return Short Duration (10min - 1hr)** Long Duration (1hr - 24 hr) Formula
Period
(Year) Type A C b Type A (=I24) C (=24) b t (hr)
2 3 6.458 24 0.626 Type 3 :
Short duration curves are not

( )A
5 applicable to this form. b
3 9.583 24 0.626
C
10 3 11.250 24 0.626 R=
t
25 3 13.750 24 0.626

50 3 15.208 24 0.626 A = I24

100 3 16.667 24 0.626 C = 24

(2-4) Method 4 : Manual input of hourly rainfall values (Go to Sheet "04Method4")
03R2yr

Runoff Analysis Input Data Processing Form

Developing Hourly Rainfall Hyetograph by Alternating Block Method

Selected Method
X Method 1 : Apply FCSEC's RIDF curves at a PAGASA synoptic station

Method 2: Manual input of coefficients for RDIF curves

Method 3: Develop RIDF curves based on iso-specific coefficient & isohyet of probable 1-day rain

Method 4: Manual input of hourly rainfall values (This sheet is not used. Go to Sheet "04Method4")

3-1.(1) Hourly Rainfall Distribution (Total Rainfall) (2-year Probable Rain)


Return Period (Year) 2 PAGASA Synoptic Station 741 #VALUE!
RIDF Curve Type 2 Coefficients A 4471.45 C 14.83 b 0.92
Storm (Rainfall) Duration for Runoff Analysis (Select from "7", "13" or "24" hours) 24
Duration Intensity Cumula- Incremen- Hourly Rainfall Distribution

(hour) (mm/hr) tive (mm) tal (mm/hr) by Alternating Block Method


Design Hyetograph
(Total Rain, Point Rainfall)
a c d=c*a 7 hour 13 hour 24 hour
1 84.39 84.39 84.39 0.44
90
2 49.10 98.20 13.81 0.71
80
3 34.99 104.97 6.77 0.61

4 27.33 109.32 4.35 0.69 70

5 22.50 112.50 3.18 0.75


60
6 19.17 115.02 2.52 0.92
Rainfall (mm/hr)

50
7 16.72 117.04 2.02 1.08

8 14.84 118.72 1.68 1.36 40

9 13.36 120.24 1.52 1.68


30
10 12.16 121.60 1.36 2.52
20
11 11.16 122.76 1.16 4.35

12 10.32 123.84 1.08 13.81 10

13 9.60 124.80 0.96 84.39


0
7 1 24
14 8.98 125.72 0.92 6.77 3
Time (hour)

15 8.43 126.45 0.73 3.18

16 7.95 127.20 0.75 2.02

17 7.53 128.01 0.81 1.52

18 7.15 128.70 0.69 1.16

19 6.81 129.39 0.69 0.96

20 6.50 130.00 0.61 0.73

21 6.21 130.41 0.41 0.81

22 5.96 131.12 0.71 0.69

23 5.72 131.56 0.44 0.41

24 5.50 132.00 0.44 0.44


03R2yr

Total 132.00
Note : The above rainfall amount is the total rainfall, and losses are not considered.
An area reduction factor for Method 1 (and for Methods 2 and 4, according to conditions) are not considered yet.

Area reduction factor should be manually input on Table (2).


03R2yr

Data Input Format for HEC-HMS

3-1.(2) Hourly Rainfall Distribution (Excess Rain with Area Reduction)


Name of River SIBUGUEY RIVER Return Period (Year) 2 Rainfall Duration (hour) 24
C. A. (km ) *
2
800.3 * :The total catchment area of all sub-basins.
Area Reduction Factor fa 0.5536
Area Reduction Factor fa for Method 1: Value computed in the above cell
Applied 0.7745 for Method 2: 1.0 or value in the above cell (case-by-case)
for Method 3: 1.0
Manual Input

Time Total Rain Loss Excess Rain


Design Hyetograph
(adjusted by fa) (%)
(Excess Rain, Basin Rainfall)
(hour) (mm/hr) (mm/hr) (mm/hr) to total
1 0.34 0.00 0.34 0.33%
2 0.55 0.00 0.55 0.54% 70
3 0.47 0.00 0.47 0.46%
4 0.53 0.00 0.53 0.52%
60
5 0.58 0.00 0.58 0.57%
6 0.71 0.00 0.71 0.69%
7 0.84 0.00 0.84 0.82% 50
8 1.05 0.00 1.05 1.03%
9 1.30 0.00 1.30 1.27%
40
Rainfall (mm/hr)

10 1.95 0.00 1.95 1.91%


11 3.37 0.00 3.37 3.30%
12 10.70 0.00 10.70 10.47% 30

13 65.36 0.00 65.36 63.94%


14 5.24 0.00 5.24 5.13%
20
15 2.46 0.00 2.46 2.41%
16 1.56 0.00 1.56 1.53%
17 1.18 0.00 1.18 1.15% 10

18 0.90 0.00 0.90 0.88%


19 0.74 0.00 0.74 0.72%
0
7 1 24
20 0.57 0.00 0.57 0.56% 3
Time (hour)
21 0.63 0.00 0.63 0.62%
22 0.53 0.00 0.53 0.52%
23 0.32 0.00 0.32 0.31%
24 0.34 0.00 0.34 0.33%
Total 102.22 0.00 102.22 100.0%
Max. 65.36 0.00 65.36 63.94%

HEC-HMS Input Data


03R5yr

Runoff Analysis Input Data Processing Form

Developing Hourly Rainfall Hyetograph by Alternating Block Method

Selected Method
X Method 1 : Apply FCSEC's RIDF curves at a PAGASA synoptic station

Method 2: Manual input of coefficients for RDIF curves

Method 3: Develop RIDF curves based on iso-specific coefficient & isohyet of probable 1-day rain

Method 4: Manual input of hourly rainfall values (This sheet is not used. Go to Sheet "04Method4")

3-2.(1) Hourly Rainfall Distribution (Total Rainfall) (5-year Probable Rain)


Return Period (Year) 5 PAGASA Synoptic Station 741 #VALUE!
RIDF Curve Type 2 Coefficients A 7333.6 C 6.41 b 0.96
Storm (Rainfall) Duration for Runoff Analysis (Select from "7", "13" or "24" hours) 24
Duration Intensity Cumula- Incremen- Hourly Rainfall Distribution

(hour) (mm/hr) tive (mm) tal (mm/hr) by Alternating Block Method


Design Hyetograph
(Total Rain, Point Rainfall)
a c d=c*a 7 hour 13 hour 24 hour
1 130.61 130.61 130.61 0.34
140
2 70.41 140.82 10.21 0.23
130

3 48.49 145.47 4.65 0.28 120

4 37.10 148.40 2.93 0.43 110

100
5 30.09 150.45 2.05 0.54
90
6 25.35 152.10 1.65 0.56
80
Rainfall (mm/hr)

7 21.91 153.37 1.27 0.71


70
8 19.31 154.48 1.11 0.87 60

9 17.27 155.43 0.95 1.11 50

10 15.63 156.30 0.87 1.65 40

30
11 14.27 156.97 0.67 2.93
20
12 13.14 157.68 0.71 10.21
10
13 12.18 158.34 0.66 130.61
0
7 1 24
14 11.35 158.90 0.56 4.65 3
Time (hour)

15 10.62 159.30 0.40 2.05

16 9.99 159.84 0.54 1.27

17 9.43 160.31 0.47 0.95

18 8.93 160.74 0.43 0.67

19 8.48 161.12 0.38 0.66

20 8.07 161.40 0.28 0.40

21 7.71 161.91 0.51 0.47

22 7.37 162.14 0.23 0.38

23 7.06 162.38 0.24 0.51

24 6.78 162.72 0.34 0.24


03R5yr

Total 162.72
Note : The above rainfall amount is the total rainfall, and losses are not considered.
An area reduction factor for Method 1 (and for Methods 2 and 4, according to conditions) are not considered yet.

Area reduction factor should be manually input on Table (2).


03R5yr

Data Input Format for HEC-HMS

3-2.(2) Hourly Rainfall Distribution (Excess Rain with Area Reduction)


Name of River SIBUGUEY RIVER Return Period (Year) 5 Rainfall Duration (hour) 24
C. A. (km ) *
2
800.3 * :The total catchment area of all sub-basins.
Area Reduction Factor fa 0.5536
Area Reduction Factor fa for Method 1: Value computed in the above cell
Applied 0.7745 for Method 2: 1.0 or value in the above cell (case-by-case)
for Method 3: 1.0
Manual Input

Time Total Rain Loss Excess Rain


Design Hyetograph
(adjusted by fa) (%)
(Excess Rain, Basin Rainfall)
(hour) (mm/hr) (mm/hr) (mm/hr) to total
1 0.26 0.00 0.26 0.21%
2 0.18 0.00 0.18 0.14% 110
3 0.22 0.00 0.22 0.17%
100
4 0.33 0.00 0.33 0.26%
5 0.42 0.00 0.42 0.33% 90
6 0.43 0.00 0.43 0.34%
7 0.55 0.00 0.55 0.44% 80

8 0.67 0.00 0.67 0.53%


70
9 0.86 0.00 0.86 0.68%
Rainfall (mm/hr)

10 1.28 0.00 1.28 1.02% 60

11 2.27 0.00 2.27 1.80%


50
12 7.91 0.00 7.91 6.28%
13 101.16 0.00 101.16 80.27% 40
14 3.60 0.00 3.60 2.86%
30
15 1.59 0.00 1.59 1.26%
16 0.98 0.00 0.98 0.78% 20
17 0.74 0.00 0.74 0.59%
18 0.52 0.00 0.52 0.41% 10

19 0.51 0.00 0.51 0.40%


0
7 1 24
20 0.31 0.00 0.31 0.25% 3
Time (hour)
21 0.36 0.00 0.36 0.29%
22 0.29 0.00 0.29 0.23%
23 0.39 0.00 0.39 0.31%
24 0.19 0.00 0.19 0.15%
Total 126.02 0.00 126.02 100.0%
Max. 101.16 0.00 101.16 80.27%

HEC-HMS Input Data


03R10yr

Runoff Analysis Input Data Processing Form

Developing Hourly Rainfall Hyetograph by Alternating Block Method

Selected Method
X Method 1 : Apply FCSEC's RIDF curves at a PAGASA synoptic station

Method 2: Manual input of coefficients for RDIF curves

Method 3: Develop RIDF curves based on iso-specific coefficient & isohyet of probable 1-day rain

Method 4: Manual input of hourly rainfall values (This sheet is not used. Go to Sheet "04Method4")

3-3.(1) Hourly Rainfall Distribution (Total Rainfall) (10-year Probable Rain)


Return Period (Year) 10 PAGASA Synoptic Station 741 #VALUE!
RIDF Curve Type 2 Coefficients A 10115.33 C 6.09 b 0.98
Storm (Rainfall) Duration for Runoff Analysis (Select from "7", "13" or "24" hours) 24
Duration Intensity Cumula- Incremen- Hourly Rainfall Distribution

(hour) (mm/hr) tive (mm) tal (mm/hr) by Alternating Block Method


Design Hyetograph
(Total Rain, Point Rainfall)
a c d=c*a 7 hour 13 hour 24 hour
1 166.44 166.44 166.44 0.27
180
2 88.37 176.74 10.30 0.20 170
160
3 60.35 181.05 4.31 0.36
150
4 45.89 183.56 2.51 0.34 140
130
5 37.06 185.30 1.74 0.31
120
6 31.09 186.54 1.24 0.42 110
Rainfall (mm/hr)

100
7 26.80 187.60 1.06 0.49
90
8 23.55 188.40 0.80 0.61 80
70
9 21.01 189.09 0.69 0.80
60
10 18.97 189.70 0.61 1.24 50
40
11 17.29 190.19 0.49 2.51
30
12 15.89 190.68 0.49 10.30 20
10
13 14.70 191.10 0.42 166.44
0
7 1 24
14 13.68 191.52 0.42 4.31 3
Time (hour)

15 12.79 191.85 0.33 1.74

16 12.01 192.16 0.31 1.06

17 11.32 192.44 0.28 0.69

18 10.71 192.78 0.34 0.49

19 10.16 193.04 0.26 0.42

20 9.67 193.40 0.36 0.33

21 9.22 193.62 0.22 0.28

22 8.81 193.82 0.20 0.26

23 8.43 193.89 0.07 0.22

24 8.09 194.16 0.27 0.07


03R10yr

Total 194.16
Note : The above rainfall amount is the total rainfall, and losses are not considered.
An area reduction factor for Method 1 (and for Methods 2 and 4, according to conditions) are not considered yet.

Area reduction factor should be manually input on Table (2).


03R10yr

Data Input Format for HEC-HMS

3-3.(2) Hourly Rainfall Distribution (Excess Rain with Area Reduction)


Name of River SIBUGUEY RIVER Return Period (Year) 10 Rainfall Duration (hour) 24
C. A. (km ) *
2
800.3 * :The total catchment area of all sub-basins.
Area Reduction Factor fa 0.5536
Area Reduction Factor fa for Method 1: Value computed in the above cell
Applied 0.7745 for Method 2: 1.0 or value in the above cell (case-by-case)
for Method 3: 1.0
Manual Input

Time Total Rain Loss Excess Rain


Design Hyetograph
(adjusted by fa) (%)
(Excess Rain, Basin Rainfall)
(hour) (mm/hr) (mm/hr) (mm/hr) to total
1 0.21 0.00 0.21 0.14%
2 0.15 0.00 0.15 0.10% 140
3 0.28 0.00 0.28 0.19%
130
4 0.26 0.00 0.26 0.17%
120
5 0.24 0.00 0.24 0.16%
6 0.33 0.00 0.33 0.22% 110

7 0.38 0.00 0.38 0.25% 100


8 0.47 0.00 0.47 0.31% 90
9 0.62 0.00 0.62 0.41%
80
Rainfall (mm/hr)

10 0.96 0.00 0.96 0.64%


70
11 1.94 0.00 1.94 1.29%
12 7.98 0.00 7.98 5.31% 60

13 128.91 0.00 128.91 85.72% 50


14 3.34 0.00 3.34 2.22%
40
15 1.35 0.00 1.35 0.90%
30
16 0.82 0.00 0.82 0.55%
17 0.53 0.00 0.53 0.35% 20

18 0.38 0.00 0.38 0.25% 10


19 0.33 0.00 0.33 0.22%
0
7 1 24
20 0.26 0.00 0.26 0.17% 3
Time (hour)
21 0.22 0.00 0.22 0.15%
22 0.20 0.00 0.20 0.13%
23 0.17 0.00 0.17 0.11%
24 0.05 0.00 0.05 0.03%
Total 150.38 0.00 150.38 100.0%
Max. 128.91 0.00 128.91 85.72%

HEC-HMS Input Data


03R25yr

Runoff Analysis Input Data Processing Form

Developing Hourly Rainfall Hyetograph by Alternating Block Method

Selected Method
X Method 1 : Apply FCSEC's RIDF curves at a PAGASA synoptic station

Method 2: Manual input of coefficients for RDIF curves

Method 3: Develop RIDF curves based on iso-specific coefficient & isohyet of probable 1-day rain

Method 4: Manual input of hourly rainfall values (This sheet is not used. Go to Sheet "04Method4")

3-4.(1) Hourly Rainfall Distribution (Total Rainfall) (25-year Probable Rain)


Return Period (Year) 25 PAGASA Synoptic Station 741 #VALUE!
RIDF Curve Type 2 Coefficients A 13013.41 C 6.09 b 0.99
Storm (Rainfall) Duration for Runoff Analysis (Select from "7", "13" or "24" hours) 24
Duration Intensity Cumula- Incremen- Hourly Rainfall Distribution

(hour) (mm/hr) tive (mm) tal (mm/hr) by Alternating Block Method


Design Hyetograph
(Total Rain, Point Rainfall)
a c d=c*a 7 hour 13 hour 24 hour
1 205.33 205.33 205.33 0.25
220
2 108.32 216.64 11.31 0.04 210
200
3 73.68 221.04 4.40 0.18 190
180
4 55.87 223.48 2.44 0.27 170
160
5 45.02 225.10 1.62 0.33 150
140
6 37.71 226.26 1.16 0.20
130
Rainfall (mm/hr)

120
7 32.45 227.15 0.89 0.33
110
8 28.48 227.84 0.69 0.48 100
90
9 25.38 228.42 0.58 0.69 80
70
10 22.89 228.90 0.48 1.16 60
50
11 20.85 229.35 0.45 2.44 40
30
12 19.14 229.68 0.33 11.31 20
10
13 17.70 230.10 0.42 205.33
0
7 1 24
14 16.45 230.30 0.20 4.40 3
Time (hour)

15 15.37 230.55 0.25 1.62

16 14.43 230.88 0.33 0.89

17 13.59 231.03 0.15 0.58

18 12.85 231.30 0.27 0.45

19 12.18 231.42 0.12 0.42

20 11.58 231.60 0.18 0.25

21 11.04 231.84 0.24 0.15

22 10.54 231.88 0.04 0.12

23 10.09 232.07 0.19 0.24

24 9.68 232.32 0.25 0.19


03R25yr

Total 232.32
Note : The above rainfall amount is the total rainfall, and losses are not considered.
An area reduction factor for Method 1 (and for Methods 2 and 4, according to conditions) are not considered yet.

Area reduction factor should be manually input on Table (2).


03R25yr

Data Input Format for HEC-HMS

3-4.(2) Hourly Rainfall Distribution (Excess Rain with Area Reduction)


Name of River SIBUGUEY RIVER Return Period (Year) 25 Rainfall Duration (hour) 24
C. A. (km ) *
2
800.3 * :The total catchment area of all sub-basins.
Area Reduction Factor fa 0.5536
Area Reduction Factor fa for Method 1: Value computed in the above cell
Applied 0.7745 for Method 2: 1.0 or value in the above cell (case-by-case)
for Method 3: 1.0
Manual Input

Time Total Rain Loss Excess Rain


Design Hyetograph
(adjusted by fa) (%)
(Excess Rain, Basin Rainfall)
(hour) (mm/hr) (mm/hr) (mm/hr) to total
1 0.19 0.00 0.19 0.11%
2 0.03 0.00 0.03 0.02% 170
3 0.14 0.00 0.14 0.08% 160
4 0.21 0.00 0.21 0.12% 150
5 0.26 0.00 0.26 0.14% 140
6 0.15 0.00 0.15 0.08% 130
7 0.26 0.00 0.26 0.14% 120
8 0.37 0.00 0.37 0.21% 110
9 0.53 0.00 0.53 0.29% 100
Rainfall (mm/hr)

10 0.90 0.00 0.90 0.50% 90


11 1.89 0.00 1.89 1.05% 80
12 8.76 0.00 8.76 4.87% 70
13 159.03 0.00 159.03 88.38% 60
14 3.41 0.00 3.41 1.90% 50
15 1.25 0.00 1.25 0.69% 40
16 0.69 0.00 0.69 0.38% 30
17 0.45 0.00 0.45 0.25% 20
18 0.35 0.00 0.35 0.19%
10
19 0.33 0.00 0.33 0.18%
0
7 1 24
20 0.19 0.00 0.19 0.11% 3
Time (hour)
21 0.12 0.00 0.12 0.07%
22 0.09 0.00 0.09 0.05%
23 0.19 0.00 0.19 0.11%
24 0.15 0.00 0.15 0.08%
Total 179.94 0.00 179.94 100.0%
Max. 159.03 0.00 159.03 88.38%

HEC-HMS Input Data


03R50yr

Runoff Analysis Input Data Processing Form

Developing Hourly Rainfall Hyetograph by Alternating Block Method

Selected Method
X Method 1 : Apply FCSEC's RIDF curves at a PAGASA synoptic station

Method 2: Manual input of coefficients for RDIF curves

Method 3: Develop RIDF curves based on iso-specific coefficient & isohyet of probable 1-day rain

Method 4: Manual input of hourly rainfall values (This sheet is not used. Go to Sheet "04Method4")

3-5.(1) Hourly Rainfall Distribution (Total Rainfall) (50-year Probable Rain)


Return Period (Year) 50 PAGASA Synoptic Station 741 Dipolog
RIDF Curve Type 2 Coefficients A 12494.34 C 6.09 b 0.98
Storm (Rainfall) Duration for Runoff Analysis (Select from "7", "13" or "24" hours) 24
Duration Intensity Cumula- Incremen- Hourly Rainfall Distribution
Design Hyetograph
(hour) (mm/hr) tive (mm) tal (mm/hr) by Alternating Block Method
(Total Rain, Point Rainfall)
a c d=c*a 7 hour 13 hour 24 hour
1 205.58 205.58 205.58 0.10
220
2 109.16 218.32 12.74 0.38 210
200
3 74.54 223.62 5.30 0.35 190
180
4 56.68 226.72 3.10 0.31 170
160
5 45.77 228.85 2.13 0.44 150
140
6 38.41 230.46 1.61 0.52
130
Rainfall (mm/hr)

120
7 33.10 231.70 1.24 0.60
110
8 29.09 232.72 1.02 0.75 100
90
9 25.95 233.55 0.83 1.02 80
70
10 23.43 234.30 0.75 1.61 60
50
11 21.36 234.96 0.66 3.10 40
30
12 19.63 235.56 0.60 12.74 20
10
13 18.16 236.08 0.52 205.58
0
7 1 24
14 16.90 236.60 0.52 5.30 3
Time (hour)

15 15.80 237.00 0.40 2.13

16 14.84 237.44 0.44 1.24

17 13.99 237.83 0.39 0.83

18 13.23 238.14 0.31 0.66

19 12.55 238.45 0.31 0.52

20 11.94 238.80 0.35 0.40

21 11.38 238.98 0.18 0.39

22 10.88 239.36 0.38 0.31

23 10.42 239.66 0.30 0.18

24 9.99 239.76 0.10 0.30

Total 239.76
Note : The above rainfall amount is the total rainfall, and losses are not considered.
An area reduction factor for Method 1 (and for Methods 2 and 4, according to conditions) are not considered yet.

Area reduction factor should be manually input on Table (2).


03R50yr
Area reduction factor should be manually input on Table (2).
03R50yr

Data Input Format for HEC-HMS

3-5.(2) Hourly Rainfall Distribution (Excess Rain with Area Reduction)


Name of River SIBUGUEY RIVER Return Period (Year) 50 Rainfall Duration (hour) 24
C. A. (km ) *
2
800.3 * :The total catchment area of all sub-basins.
Area Reduction Factor fa 0.5536
Area Reduction Factor fa for Method 1: Value computed in the above cell
Applied 0.6441 for Method 2: 1.0 or value in the above cell (case-by-case)
for Method 3: 1.0
Manual Input

Time Total Rain Loss Excess Rain


Design Hyetograph
(adjusted by fa) (%)
(Excess Rain, Basin Rainfall)
(hour) (mm/hr) (mm/hr) (mm/hr) to total
1 0.06 0.00 0.06 0.04%
2 0.24 0.00 0.24 0.16% 140
3 0.23 0.00 0.23 0.15%
130
4 0.20 0.00 0.20 0.13%
120
5 0.28 0.00 0.28 0.18%
6 0.33 0.00 0.33 0.21% 110

7 0.39 0.00 0.39 0.25% 100


8 0.48 0.00 0.48 0.31% 90
9 0.66 0.00 0.66 0.43%
80
Rainfall (mm/hr)
10 1.04 0.00 1.04 0.67%
70
11 2.00 0.00 2.00 1.30%
12 8.21 0.00 8.21 5.32% 60

13 132.41 0.00 132.41 85.75% 50


14 3.41 0.00 3.41 2.21% 40
15 1.37 0.00 1.37 0.89%
30
16 0.80 0.00 0.80 0.52%
20
17 0.53 0.00 0.53 0.34%
18 0.43 0.00 0.43 0.28% 10

19 0.33 0.00 0.33 0.21% 0


7 1 24
20 0.26 0.00 0.26 0.17% 3
Time (hour)
21 0.25 0.00 0.25 0.16%
22 0.20 0.00 0.20 0.13%
23 0.12 0.00 0.12 0.08%
24 0.19 0.00 0.19 0.12%
Total 154.42 0.00 154.42 100.0%
Max. 132.41 0.00 132.41 85.75%

HEC-HMS Input Data


03R100yr

Runoff Analysis Input Data Processing Form

Developing Hourly Rainfall Hyetograph by Alternating Block Method

Selected Method
X Method 1 : Apply FCSEC's RIDF curves at a PAGASA synoptic station

Method 2: Manual input of coefficients for RDIF curves

Method 3: Develop RIDF curves based on iso-specific coefficient & isohyet of probable 1-day rain

Method 4: Manual input of hourly rainfall values (This sheet is not used. Go to Sheet "04Method4")

3-6.(1) Hourly Rainfall Distribution (Total Rainfall) (100-year Probable Rain)


Return Period (Year) 100 PAGASA Synoptic Station 741 Dipolog
RIDF Curve Type 2 Coefficients A 14708.26 C 6.09 b 0.99
Storm (Rainfall) Duration for Runoff Analysis (Select from "7", "13" or "24" hours) 24
Duration Intensity Cumula- Incremen- Hourly Rainfall Distribution

(hour) (mm/hr) tive (mm) tal (mm/hr) by Alternating Block Method


Design Hyetograph
(Total Rain, Point Rainfall)
a c d=c*a 7 hour 13 hour 24 hour
1 232.07 232.07 232.07 0.13
250
2 122.43 244.86 12.79 0.16 240
230
3 83.28 249.84 4.98 0.17 220
210
4 63.15 252.60 2.76 0.24 200
190
180
5 50.88 254.40 1.80 0.26
170
160
6 42.62 255.72 1.32 0.40 150
Rainfall (mm/hr)

140
7 36.67 256.69 0.97 0.52 130
120
8 32.19 257.52 0.83 0.49 110
100
9 28.69 258.21 0.69 0.83 90
80
10 25.87 258.70 0.49 1.32 70
60
11 23.56 259.16 0.46 2.76 50
40
12 21.64 259.68 0.52 12.79 30
20
10
13 20.00 260.00 0.32 232.07
0
7 1 24
14 18.60 260.40 0.40 4.98 3
Time (hour)

15 17.38 260.70 0.30 1.80

16 16.31 260.96 0.26 0.97

17 15.36 261.12 0.16 0.69

18 14.52 261.36 0.24 0.46

19 13.77 261.63 0.27 0.32

20 13.09 261.80 0.17 0.30

21 12.48 262.08 0.28 0.16

22 11.92 262.24 0.16 0.27

23 11.41 262.43 0.19 0.28

24 10.94 262.56 0.13 0.19

Total 262.56
Note : The above rainfall amount is the total rainfall, and losses are not considered.
An area reduction factor for Method 1 (and for Methods 2 and 4, according to conditions) are not considered yet.

Area reduction factor should be manually input on Table (2).


03R100yr

Data Input Format for HEC-HMS

3-6.(2) Hourly Rainfall Distribution (Excess Rain with Area Reduction)


Name of River SIBUGUEY RIVER Return Period (Year) 100 Rainfall Duration (hour) 24
C. A. (km2) * 800.3 * :The total catchment area of all sub-basins.
Area Reduction Factor fa 0.5536
Area Reduction Factor fa for Method 1: Value computed in the above cell
Applied 0.5536 for Method 2: 1.0 or value in the above cell (case-by-case)
for Method 3: 1.0
Manual Input

Time Total Rain Loss Excess Rain


Design Hyetograph
(adjusted by fa) (%)
(Excess Rain, Basin Rainfall)
(hour) (mm/hr) (mm/hr) (mm/hr) to total
1 0.07 0.00 0.07 0.05%
2 0.09 0.00 0.09 0.06% 140

3 0.09 0.00 0.09 0.06% 130


4 0.13 0.00 0.13 0.09% 120
5 0.14 0.00 0.14 0.10%
110
6 0.22 0.00 0.22 0.15%
7 0.29 0.00 0.29 0.20% 100

8 0.27 0.00 0.27 0.19% 90


9 0.46 0.00 0.46 0.32% 80
Rainfall (mm/hr)
10 0.73 0.00 0.73 0.50%
70
11 1.53 0.00 1.53 1.05%
12 7.08 0.00 7.08 4.87% 60

13 128.47 0.00 128.47 88.38% 50

14 2.76 0.00 2.76 1.90% 40


15 1.00 0.00 1.00 0.69%
30
16 0.54 0.00 0.54 0.37%
20
17 0.38 0.00 0.38 0.26%
18 0.25 0.00 0.25 0.17% 10

19 0.18 0.00 0.18 0.12% 0


7 1 24
20 0.17 0.00 0.17 0.12% 3
Time (hour)
21 0.09 0.00 0.09 0.06%
22 0.15 0.00 0.15 0.10%
23 0.16 0.00 0.16 0.11%
24 0.11 0.00 0.11 0.08%
Total 145.36 0.00 145.36 100.0%
Max. 128.47 0.00 128.47 88.38%

HEC-HMS Input Data


04Method4

Runoff Analysis Input Data Processing Form

Developing Hourly Rainfall Hyetograph by Alternating Block Method

Selected Method
X Method 1 : Apply FCSEC's RIDF curves at a PAGASA synoptic station

Method 2: Manual input of coefficients for RDIF curves

Method 3: Develop RIDF curves based on iso-specific coefficient & isohyet of probable 1-day rain

Method 4: Manual input of hourly rainfall values (This sheet is not used. Go to Sheet "04Method4")

Method 4 is not selected now. This sheet is not applicable.


4.(1) Hourly Rainfall Distribution (Total Rainfall)
Return Period (Year) 5

Storm (Rainfall) Duration for Runoff Analysis (Select from "7", "13" or "24" hours) 24
Time Hourly Rainfall Distribution
(hour)
Design Hyetograph
(Total Rain, PointRainfall)
a 7 hour 13 hour 24 hour
2.42
60
2.56
2.72
50
2.92

3.15
40
3.44
Rainfall (mm/hr)

3.80
30
4.29

4.98
20
6.06

8.07
10
13.99

47.84
0
7 1 24
10.01 3
Time (hour)
6.88

5.45

4.60

4.03

3.61

3.28

3.03

2.82

2.64

2.49
04Method4

Total 155.04
Note : The above rainfall amount is the total rainfall, and losses are not considered.
An area reduction factor for Method 1 (and for Methods 2 and 4, according to conditions) are not considered yet.

Area reduction factor should be manually input on Table (2).


04Method4

Data Input Format for HEC-HMS

4.(2) Hourly Rainfall Distribution (Excess Rain with Area Reduction)


Name of River SIBUGUEY RIVER Return Period (Year) 5 Rainfall Duration (hour) 24
C. A. (km ) *
2
800.3 * :The total catchment area of all sub-basins.
Area Reduction Factor fa 0.5536
Area Reduction Factor fa Input 1.0 or the computed fa value in the above cell.
Applied 1.0000 Selection is according to the definition of the given rainfall data.

Manual Input

Time Total Rain Loss Excess Rain


Design Hyetograph
(adjusted by fa) (%)
(Excess Rain, Basin Rainfall)
(hour) (mm/hr) (mm/hr) (mm/hr) to total
0.00
0.00
20
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
Rainfall (mm/hr)

0.00 10
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0
0.00 7 1 24
3
0.00 Time (hour)
0.00
0.00
0.00
Total 0.00
Max. 0.00

HEC-HMS Input Data


Rainfall Data (100-YEAR)
Input Climate Change 50% (+10%)
0.07 0.077 0.07
0.09 0.099 0.09
0.09 0.099 0.09
0.13 0.143 0.13
0.14 0.154 0.14
0.22 0.242 0.22
0.29 0.319 0.29
0.27 0.297 0.27
0.46 0.506 0.46
0.73 0.803 0.73
1.53 1.683 1.53
7.08 7.788 7.08
128.47 141.317 128.47
2.76 3.036 2.76
1 1.100 1
0.54 0.594 0.54
0.38 0.418 0.38
0.25 0.275 0.25
0.18 0.198 0.18
0.17 0.187 0.17
0.09 0.099 0.09
0.15 0.165 0.15
0.16 0.176 0.16
0.11 0.121 0.11