Hierarchy of
Elements
Low Low
Pressure, High Pressure,
Low Flow Pressure, Low Flow
Rate Zone High Flow Rate Zone
< 4 Bar Rate Zone < 4 Bar
> 4 Bar
Number Letter
Arrow shows
direction of
Flow Control
BITS Pilani, K K Birla Goa Campus
Flow Control
Forward Motion
4 2 OR
Exhaust air leaving the front side of the
cylinder (Meter-Out).
1
Air Pressure
BITS Pilani, K K Birla Goa Campus
Inlet Flow Control
Controlling speed in Air entering the cylinder is throttled, while air
both directions with leaving the cylinder flows at full speed.
Inlet Flow Control
Forward speed of the cylinder is controlled by
the valve on the rear side of the cylinder.
• Amount of delay
depends on setting of
flow control valve and
size of reservoir.
• Timing starts from the
time the sensing input
[12] receives a signal.
• Timer is reset when
signal to sensing input
[12] is withdrawn.
Port Port
Blocked Blocked
4 2 4 2
1 1
A 3/2 Normally Closed valve can A 3/2 Normally Open valve can be
be created by blocking the created by blocking the normally
normally open port [2]. closed port [4].
Mounting Arrangements
for Limit Switches
BITS Pilani, K K Birla Goa Campus
Mounting of Components
Blocking of two
Press blue ring and connectors
gently pull the tube
to disconnect Blocking a single
connector
BITS Pilani, K K Birla Goa Campus
Regulating Pressure
Output valve
No components should be
fixed in front of a cylinder.