NEWPORT BREEZE

from Newport Medical Instruments


E150pptcy0606 REV. A 1
NEWPORT BREEZE
NOW YOUR VENTILATOR CAN BE IN
THREE PLACES AT ONCE!

 NEONATAL ICU
 PEDIATRIC ICU
 ADULT ICU

E150pptcy0606 REV. A 2
NEWPORT BREEZE
DESIGN ELEMENTS

Unique DuoFlow System -


Intermittent Spontaneous Flow (ISF )
TM

Low Work of Breathing.


Safety, Reliability, Accuracy and Ease
of Operation.

E150pptcy0606 REV. A 3
NEWPORT BREEZE
DESIGN ELEMENTS
Unique Standard Functions
 Volume Controlled Ventilation
 Pressure Controlled Ventilation
 SIMV
 Inverse I:E Ratio Ventilation
 Enhanced Monitoring
 PROXIMAL Pressure Monitoring
 Internal Battery (1 Hour)
 Built-in Nebulizer Drive
E150pptcy0606 REV. A 4
NEWPORT BREEZE
DESIGN ELEMENTS
Logical layout of patient controls:

 Red for alarm limit displays.


 Yellow for data and information.
 Green for patient breath
controls.

E150pptcy0606 REV. A 5
NEWPORT BREEZE
DESIGN ELEMENTS
Enhanced Monitoring & Displays:

Electronic Pressure Gauge


Peak, Mean, and Base Pressures
Tidal Volume
I:E Ratio
f TOTAL
Expiratory Time
E150pptcy0606 REV. A 6
NEWPORT BREEZE
DESIGN ELEMENTS
Patient Protection:
 High Inspiratory Pressure Alarm
 Low Inspiratory Pressure Alarm
 Low Baseline Baseline Alarm
 Apnea Alarm
 Gas Supply Alarm
 Power Down Alarm
 Low Battery Alarm
E150pptcy0606 REV. A 7
NEWPORT BREEZE
ADVANCED FUNCTION
“100% SIMV” Window

E150pptcy0606 REV. A 8
NEWPORT BREEZE
ADVANCED FUNCTION
Unique Flow System - DUOFLOW
SINGLE DUO-FLOW
DUO-FLOWSYSTEM
SINGLEFLOW
FLOWSYSTEM
SYSTEM HIGH
SYSTEM
HIGH
AA CONSTANT
CONSTANT
FLOW
FLOW
HIGH
AA HIGH
CONSTANT
CONSTANT
FLOW ONE WAY
ONE WAY
FLOW VALVE
EXHALATION VALVE
EXHALATION
VALVE
VALVE
CLOSED
CLOSED EXHALATION
EXHALATION
VALVE
PATIENT VALVE
PATIENT BB HIGH
HIGH
CONSTANT
CONSTANT
CLOSED
CLOSED
FLOW PATIENT
HIGH FLOW PATIENT
BB HIGH
CONSTANT
CONSTANT
FLOW
FLOW ONE WAY
EXHALATION ONE WAY
VALVE
EXHALATION VALVE
VALVE
VALVE
OPENED
OPENED
PATIENT EXHALATION
PATIENT A. CMV Inspiration EXHALATION
A. CMV Inspiration VALVE
B. CMV Expiration, Spontaneous Inspiration VALVE
A. CMV Inspiration B. CMV Expiration, Spontaneous Inspiration OPENED
A. CMV Inspiration
B. CMV Expiration, Spontaneous Inspiration and Expiration
and Expiration
B. CMV Expiration, Spontaneous Inspiration and Expiration E150pptcy0606 REV. A
and Expiration PATIENT 9OPENED
PATIENT
NEWPORT BREEZE
ADVANCED FUNCTION
Unique Flow System - DUOFLOW
Duoflow
Duoflow allows
allows you you to
to control
control Mandatory
Mandatory andand Spontaneous
Spontaneous Flow Flow
separately.
separately. Mandatory
Mandatory Flow Flow isis delivered
delivered during
during mandatory
mandatory inspiration
inspiration
only,
only, Spontaneous
Spontaneous Flow Flow isis directed
directed through
through the
the circuit
circuit inin between
between
mandatory
mandatory breaths.
breaths. Spont.
Spont. Flow
Flow serves
serves as
as the
the source
source gas gas for
for spontaneous
spontaneous
breathing
breathing inin the
the SPONT
SPONT or or SIMV
SIMV Modes.
Modes.

Flow ISF
ISF DuoFlow
DuoFlow
Flow
system
system
Time
Time
Mandatory
MandatoryFlow
Flow
Spontaneous
SpontaneousFlow
Flow
Mandatory
Mandatory Spontaneous
Spontaneous
Breath
Breath Breath
Breath
E150pptcy0606 REV. A 10
NEWPORT BREEZE
ADVANCED FUNCTION
Unique Flow System - DUOFLOW
Spontaneous
Spontaneous Flow Flow isis calibrated
calibrated from
from
Minimum
Minimum to to 28
28 L/min.
L/min. WhenWhen thethe knob
knob isis
turned
turned toto "flush",
"flush", approx.
approx. 58 58 L/min.
L/min. isis
available.
available. Set Set Spont.
Spont. Flow
Flow to
to meet
meet pt.
pt.
spontaneous
spontaneous inspiratory
inspiratory demands
demands during
during
spontaneous
spontaneous breathing
breathing inin SIMV
SIMV and
and
Spontaneous
Spontaneous Modes Modes ofof Ventilation.
Ventilation. IfIf
patient
patient effort
effort exceeds
exceeds Spont.
Spont. Flow,
Flow, the
the
patient
patient may
may draw
draw mixed
mixed gas gas from
from the
the
Reservoir
Reservoir Bag.Bag. E150pptcy0606 REV. A 11
NEWPORT BREEZE
ADVANCED FUNCTION
Trigger Mechanism - 3 methods
Pressure
Pressure Trigger
Trigger Level
Level -- AA
trigger
trigger pressure
pressure isis set set on
on the
the
electronic
electronic manometer.
manometer. When When thethe
manometer
manometer needle needle crosses
crosses this
this
set
set level,
level, mandatory
mandatory inspiration
inspiration
will
will begin
begin ifif timing
timing isis
appropriate.
appropriate. This This control
control must
must bebe
manually
manually adjusted
adjusted to to
accommodate
accommodate PEEP PEEP levels.
levels.
E150pptcy0606 REV. A 12
NEWPORT BREEZE
ADVANCED FUNCTION
Trigger Mechanism - 3 methods

TIME
TIME--When
Whentiming
timingisis
right,
right,according
accordingtotothe
the
“SET
“SETRATE”
RATE”setting,
setting,
the
theBreeze
Breezeisistriggered
triggered
“ON”.
“ON”.

MANUAL
MANUAL--isisavailable
availablewith
withthe
the“MANUAL
“MANUAL
INFLATION”
E150pptcy0606 REV.INFLATION”
A
button.
button. 13
NEWPORT BREEZE
CLASSIFICATION
 Electronically Controlled
 Electrically and Pneumatically Driven
 Time Cycled
 Flow or Pressure Limited (Flow or Pressure may be held constant)
 Pressure, Time or Manually Triggered
 Output Control of Flow = Solenoid/pneumatic interface valve combo
 Modes (Mechanical modes may be Pressure or Volume Controlled):
Control (CMV)
Assist/Control
SIMV / IMV (Continuous Flow with ISF)
Spontaneous/CPAP (Continuous
E150pptcy0606 REV. A Flow) 14
NEWPORT BREEZE
CONTROLS & SYSTEMS
Breath Control Panel Pressure Control Panel
 Mode Selector
 Preset
 FIO2 Control
 PEEP/CPAP Control
 Mandatory Flow.
 PIP Control
 Inspiratory Time
 PAW Monitor
 Respiratory Rate
 Patient Effort Indicator
 Spontaneous Flow  Trigger Level Control
 Electronic Manometer
 Trigger Level Indicator

E150pptcy0606 REV. A 15
NEWPORT BREEZE
CONTROLS & SYSTEMS
Additional Controls Rear Panel Controls
 Manual Inflation
 Pressure Relief Valve
 Alarm Loudness
 Power Entry Module
 Nebulizer ON/OFF
 Analog Output
 Apnea Alarm Control
 RS232
 Low CPAP Alarm

E150pptcy0606 REV. A 16
NEWPORT BREEZE
PATIENT SET-UP

The
TheBreeze
Breezecancanbe
beset-up
set-upwith
withsmall
small (12
(12--15
15mm mmID)
ID)
or
orlarge
large(22
(22mmmmID)
ID)bore
bore circuit
circuittubing
tubingtoto
accommodate
accommodate ventilation
ventilationofofdifferent
differentsizes
sizes ofof patients.
patients.
Make
Makesure
suretotoappropriately
appropriatelyconnect
connectthetheproximal
proximal
sensing
sensingline
lineand
andthe
theexpiratory
expiratorydrive
driveline.
line.

E150pptcy0606 REV. A 17
NEWPORT BREEZE
PATIENT SET-UP
Volume Control
Set both the inspiratory time and the mandatory
flow to adjust tidal volume.
If the patient has a low inspiratory If the patient has an active
drive and can tolerate a longer respiratory drive with a naturally
inspiratory time, "I" time can be short natural inspiratory phase,
lengthened and flow lowered to or if you wish to decrease the
achieve the desired tidal volume. potential for auto-PEEP by
Flow 350 lengthening expiratory time, flow
mL's can be increased and "I" time
Inspiratory Time shortened to match the patient's
needs.

E150pptcy0606 REV. A 18
NEWPORT BREEZE
PATIENT SET-UP
Pressure Control
In all mechanical Pressure Controlled Modes, the
PIP knob is activated and can be set to limit the peak
inspiratory pressure for each breath.

Adjust the mandatory flow to achieve a quick rise to the


inspiratory target pressure and ideal pressure waveform. Adjust
inspiratory time to achieve a patient-compatible inspiratory
phase with adequate exhalation time. Set Intermittent
Spontaneous Flow (Spont. Flow) to achieve maximum comfort
level for spontaneous breathing.
E150pptcy0606 REV. A 19
NEWPORT BREEZE
PATIENT SET-UP
Alarms
Low Pressure Alarm functions in mechanically assisted modes
only*. Activated if the Low Pressure Alarm limit is not passed
during the inspiratory time of a mechanical breath.
* The Low Pressure Alarm setting is
also used to determine the Low
CPAP Alarm setting when
appropriate.
High Pressure Alarm Functions in all modes. Activated if the patient's
peak pressure reaches the High Pressure Alarm limit. The Breeze
automatically switches to exhalation.
E150pptcy0606 REV. A 20
NEWPORT BREEZE
PATIENT SET-UP
Alarms
Apnea Alarm Functions in all modes.
 Receives information from the Trigger Level indicator and the mandatory
breaths.
 Activated if interval between any two breaths (spont. or mandatory)
exceeds chosen delay time.
 Adjust the Trigger Level so that the Patient Effort Indicator lights with
each patient inspiration.
 During the Spont. Mode, The Apnea Alarm delay may be set in the "Low
CPAP Alarm" position. This disables the Trigger Level as a sensor for
spont. effort and enables the Low Pressure Alarm as a Low CPAP Alarm.
E150pptcy0606 REV. A 21
NEWPORT BREEZE
PATIENT SET-UP
Alarms
Alarm Silence

 Silences patient-related alarms for 60


seconds.
 Red indicator remains flashing until the
condition is corrected.

E150pptcy0606 REV. A 22
NEWPORT BREEZE
PATIENT SET-UP
Alarms
Non-Patient Related Alarms
 Cannot be silenced with the Alarm Silence Button.
 Continuous ventilator alarm indicates electrical or
mechanical system failure.
 Continuous mixer alarm indicates low inlet gas
pressure for either air or oxygen.

E150pptcy0606 REV. A 23