Cross-Passageway

Requirement
Cross passage as per NFPA 130

• No cross passages for tunnel sections not exceeding 762m between


emergency exits/exit stairways.

• For tunnel sections exceeding 750m between emergency exits, the cross
passage shall be provided no farther than 244m from the end of platform.

• Distance between cross passages shall not be more than 244m.


Cross passage as per NBC-2016

• No cross passages for tunnel sections not exceeding 750m between


emergency exits/exit stairways.

• For tunnel sections exceeding 750m between emergency exits, the first cross
passage shall be provided no farther than 500m from the end of platform.

• Distance between subsequent cross passages shall not be more than 250m.

• Crossover shall be considered as cross passage and the distance between


crossover and subsequent cross passage shall not be more than 250m.
TENDER STAGE

CP1 CP2 CP3 CP4 CP5 CP6 CP7 CP8


UGC01

C&C SN CC BP
SHAFT

(787 M) (460 M) (830 M) (160 M) (1160 M)

UGC02
CP1 CP2 CP3 CP4 CP5 CP6 CP7 CP8

BP MND SWG

(725 M) (1300 M) (160 M) (160 M)


CURRENT STAGE

CP1 CP2
UGC01

GLMTPL C&C SN CC BP
SHAFT SHAFT

(547 M) (200 M) (460 M) (830 M) (160 M) (713 M)

UGC02
CP1 CP2 CP3 CP4 CP5

BP MND SWG

(858 M) (1190 M) (160 M) (160 M)