A 250 kw, 500V, 6 pole, 600 rpm, dc generator has an armature diameter of 0.75m,
and a length of 0.3m. The lap connected armature gas 720 conductors. using the
data obtain from this machine determine the diameter length, number slots for a
350 kw, 440 V, 720 rpm, 6 pole dc generator. Assume a square pole face with a pole
arc to pole pitch ratio equal to 0.66. The efficiency is 91%, voltage drop is 4% of the
terminal voltage. The diameter of the commutator is 0.7 of armature diameter. The
pitch of commutator segments should not be less than 4mm, voltage between
adjacent commutator segments should not exceed 15V at no load.
From 250 KW machine
Pa= P/η = 250 kw/ 0.91 = 275 Kw, Pa= CoD2Ln
n= 600/60 =10, Co = (Pa/D2L n) = (275/0.752x0.3x 10) = 163
Bav= (pφ/πDL) , E = (φZN/60)x( p/a)
E = v+IaRa
IaRa = 4%of terminal voltage = 4%(500) = 20
E = 500 + 20 = 520 v.
E = (φZN/60)x( p/a) ,
Φ= (E.a)/( Z. n. p) = ( 520 x 6)/(720x10x6)= 0.0722wb.
Bav= (pφ/πDL) =(6x0.0722/ πx0.75x0.3)= 0.61 wb/m2
Using the data from first machine design second one. First machine
data are Co= 163 and Bav= 0.61 wb/m2
• n= N/60= 720/60 = 12
• Sa= 87
• Zs= Z/Sa= 493/87= 6
• Assume coil side/ slot u
• U= 2, C= uxSa/2= 2x87/2=87
• U=4 , C= uxSa/2=4x87/2 =174
• U=6, C= uxSa/2= 6x87/2 =261
U should be a divisor of conductors /slot
• Sa= 87
U= 6, Zs=6, C= 261
Commutator pitch =𝞫c = πDc/C
Dc = Commutator diameter =0.7 of armature diameter, given
number of coils = number of commutator segments
C= 261
𝞫c = πDc/C = πx 0.7 x0.835/156 = 7.03mm
So acceptable pitch is with C= 261 given by Sa=87
Final slot=87
Conductors/slot =6
Final conductors = 87x6 =522.