Acid resistant

All porcelain enamel surfaces on plumbing fixtures shall be ____.


Open-front seats
Water closet bowls fur public use shall be the elongated bowl types
equipped with ____.
Galvanized Steel
Special-use fixtures may be of soapstone chemical stoneware or may be
lined with except (A: lead, B: copper base alloy, C: nickel-copper alloy,
D: galvanized steel E: corrosion-resisting steel) or other materials
specially suited for the use which the fixture is intended.
16
Restaurant kitchen and other special-use sinks may be made of
approved-type bonderized and galvanized sheet steel of not less than
Gauge No. ___ U.S. B&S.
¼ inch
• Closet rings shall be tightly fastened with corrosive resistant fasteners
up to the floor with top surface ____ above finish floor.
344.5 kPa
In testing of water supply system, a ____ air pressure may be
substituted for the water test.
551 kPa
• Where the local water pressure is in excess of ____, an approved-
typed pressure regulator preceded by an adequately sized strainer
shall be installed to reduce the pressure on the building side of the
regulator to the required supply pressure.
½
• The minimum area of any vent installed in a CW & VS shall be at least
___ the inside cross sectional area of the drain pipe served
3
• F.U for 38 mm pipe size.
D
• Each waste pipe receiving or intended to receive the discharge of any
fixture where acid or corrosive chemical is placed and each vent pipe
connected thereto, shall be constructed of ___ except: (A: chemical-
resistant glass-lined pipe; B: silicon iron pipe; C: lead pipe; D: 3.2 mm
thickness brass pipe; E: vitrified clay)
51 mm
• Water outlet diameter if the boiler blow off is 51 mm.
Wearing plates
• ______ shall be installed in the tank to protect the shell (in condenser
or sump).
3m/0.9m
• Each vent opening shall terminate not less than ____ from, or at least
____ above any open able window, door opening, air intake or vent
shaft.
90
• A trap arm may change direction without the use of cleanout when
such change of direction does not exceed ____ degrees.
1.2 m
• The minimum distance between the door or entry to the drain
opening shall be ____.
Automatic
• Tanks flushing more than one urinal shall be ____ in operation.
559 mm
Thresholds shall be of sufficient width to accommodate a minimum
____ wide door in shower receptors specs.
4.9 meters
• Drains in gutters shall be spaced not more than ____ apart.
102 mm
• Each fixture trap shall have a water seal not more than ___ deep
except where a deeper seal is found necessary by the Administrative
Authority for special conditions.
Strainer plate
• Floor drains shall be considered plumbing fixtures and each drain shall
be provided with an approved-type and hinged _____.
0.8
• Continuous waste and fixture tailpiece shall be constructed from the
material specified on Table 14-4 of this Code for drainage piping,
provided however, that such connections where exposed or
accessible may be of seamless drawn brass not less than ____ mm in
thickness.
International Standard Organization
• ISO
Low flow
• When should be backwater valves remain sufficiently open to avoid
screening of solids and fibrous materials.
Plugs
• Shall have raised square heads or approved countersunk rectangular
slots, when cleanout is installed along travel ways.
Brass
• Each cleanout fitting for cast iron soil pipe shall consist of a cast iron
or brass body and an approved screwed ____ plug.
False
• (T or F) Brass or copper ground joint, flared or ferrule type
connections when made up, may be considered as slip joints.
Caulking ferrule
• Joints between lead pipe and cast iron, steel or wrought iron pipe
shall be made by means of ____.
C
• Joints between lead and cast iron, wrought or steel pipe shall be
made by means of ____ except (A: wiped joints, B: Caulking ferrule, C:
Brazed joint, D: soldering nipple or bushing) answer the letter.
True
• (T or F) Grease traps are not required for individual dwelling units or
for any private living quarters.
Cross-sectional area
• The aggregate ____ of vent pipes of drainage piping of each building
shall not be less than that of the largest required building sewer.
2
• ___ fixtures may be served by a common vertical vent pipe when
each such fixture wastes separately into an approved double branch
fitting having inlet openings at the same level.
0.6 m
• The building sewer, beginning ____ from outside face of wall of
building or structure, shall be of such materials as approved by
Administrative Authority.
2%
Building sewers shall be run in practical alignment at a uniform slope of
not less than ____.
6800
• Maximum fixture unit loadings on building sewer piping (2% slope) for
254 mm (10 inch) building sewer.
30
• Rainwater piping located within a medium height building basement
area shall be of galvanized iron pipe, Schedule ____.
Airgap
• All wastes drained by storage room, refrigerator, cooling counter,
compartment, receptacle, appurtenance or device used for the
storage or holding of food or drink and no dishwashing or culinary
sink in any food preparation room used for soaking, washing or
preparing ready to serve food shall discharge through an ____ into an
open floor sink or other approved type receptor.
25.4 mm
• Water outlet diameter if the boiler blow off is 32 mm.
6
• DFU for urinal, wall-mounted, blowout, integral trap, trap arm only.
6
• DFU for common horizontal and vertical waste pipe of clothes washer,
groups of 3 or more.
Ductile cast iron
• Meaning of DCI.
15 mins.
• The water shall be kept in the pipe system or in the portion under
test, for at least ___ before inspection starts.
Left
• The hot water supply for the faucets and diverters will be located at
the ____ side of the combination fittings.
0.3 m
• Water pipes crossing sewer or drainage piping constructed of clay or
materials, not approved for use within a building, shall be laid a
minimum of ___ above the sewer or drainpipe.
American National Standard Institute
• ANSI
32 mm
Each such tailpiece, continuous waste or waste and overflow shall not
be less than ____ O.D for lavatories, drinking fountains and similar
fixtures.
True
• (T or F) Fixed wooden, concrete cement, or tile wash trays or sinks for
domestic use shall not be installed in any building designed for human
habitation.
51 mm
• In no case shall any dam or threshold be less than ____ in depth when
measured from the top of the dam or threshold to the of the drain.
Soldered
• Joints in copper pans or liners shall be _____.
Interceptor
• ____ shall be provided when, in the judgment of the Administrative
Authority, they are necessary for the proper handling of liquid wastes
containing grease, flammable wastes, sand, solids, acid or alkaline
substances or other ingredients harmful to the building drainage
system, the public or private sewer and sewage disposal system.
1
• No more than ___ approved slip joint fitting may be used on the
outlet side of a trap.