• All small-sized malleable iron water fittings shall be ____.


50.8 mm
• Minimum size of any pump discharge pipe from a sump having a
water closet connected.
Pressure vacuum breaker backflow principle
backflow prevention assembly
• Meaning of PVB.
15 mins
• The pressure shall be held without introduction of additional air for a
period of at least ____.
Control gate valves
• Valves which shall be installed before each water-supplied appliance
slip joint, supply pipings for non-metallic fixture and appliance.
3 ft.
• Support trap arms in excess of ___ in length as close as possible to the
trap.
14 mesh per 25 mm
• The area of the return-bend vent pipe of the gravity tanks shall not be
less than the area of the down-feed riser pipe with a fine corrosion-
resistant screen with openings not less than ____.
True
• (True or False) No Plumbing or drainage system, building sewer
private sewer disposal system or part thereof, shall be covered,
concealed or put into use until it has been inspected, tested and
approved as prescribed in the Code.
305 mm
• Minimum clearance in front of the cleanout for piping 51 mm or less
in size.
64
• Size of cleanout for 76 mm pipe.
1
• DFU for receptors of refrigerators, coffee urns, water station, etc.
32 mm
• Minimum condensate pipe diameter of with equipment capacity of 90
tons of refrigeration (316.48 kw)
35
• Areas to be added (sizing of storm drainage) for two (2) adjacent walls
– add ____ percent of the total wall areas to the roof area
Two-way cleanout fitting
• ________ installed at connection point of building drain and building
sewer outside the building may be installed in lieu of a single clean-
out.
17
• An exposed and readily accessible drawn brass tubing trap, not less
than ____ B&S, may be used on fixtures discharging domestic sewage
but shall exclude urinals.
76 mm
• When shower receptors are built above ground the sub-floor and
rough side of walls to a height of no less than ____ above the top of
the finished dam or threshold shall be first lines with sheet lead or
copper or with other durable and watertight material.
19.56 kg
• The weight of the sheet lead shall not be less than ___ per sq. m for
safe pans.
Pressure-Lock type Connection
• Connection is made by inserting the pipe or tubing inside the fitting to
a prescribed depth.
7.6 m
• The distance required from building sewer to water supply wells may
be reduced to not less than ____ when the drainage piping is
constructed off materials approved for use within a building.
3900
• Maximum fixture unit loadings on building sewer piping (2% slope) for
203 mm (8 inch) building sewer.
True
• (True or False) No chemical vent shall be connected or intersect vents
for other services.
152 mm
• The return vent in island sinks and similar fixtures may be connected
to other vents at a point not less than ___ above the flood level rim of
the fixtures served.
2
• DFU for commercial sinks, 51 mm min. waste.
1.5
• Cleanouts may be omitted on a horizontal drain line less than ___
meter length unless if serving sinks or urinals.
2.4
• Fixture outlets hall not be connected to the horizontal excreta
drainage piping system within ____ meter of any vertical to horizontal
change of direction of a stack containing suds producing fixtures.
Double check valve backflow prevention
assembly
• Meaning of DC.
135
• Minimum angle of direction of horizontal line for no additional
cleanout.
Backflow prevention
• No person shall make a connection or allow one to exist between
pipes or conduits carrying domestic water supplied by any public or
private water service system and any pipe, conduits or fixture
containing or carrying water from any other source or containing or
carrying water which has been used for other purposes or any piping
carrying chemicals, liquids, gases or any substances unless there is
provided an approved ____ device.
Return-bend vent pipe
• The covers of gravity tanks shall be vented with ______.
38
• Minimum trap diameter (mm) for commercial or industrial, school
sinks.
Indirect wate pipe
• No cold storage room, refrigerator, cooling counter, compartment,
receptacle, appurtenance or device used for the storage or holding of
food or drink and no dishwashing or culinary sink in an food
preparation room used for soaking, washing or preparing ready to
serve food shall be drained by means of ______.
1
• DFU for drinking fountains.
51 mm
• The indirect water lines carrying refrigeration waste shall not be
smaller than ___ for 32 mm inlets or 4 to 12 m3 refrigeration space.
3 meters
• When a building sewer or a branch thereof does not exceed ____ in
length and is a short straight line extension from a building drain
which is provided with a clean out, no cleanout will be required at its
point of connection to the building drain.
Manholes
• Approved ____ may be installed in lieu of cleanouts when first
approved by the Administrative Authority.
4
• Fixtures that also serves as a vent for not to exceed ____ fixtures.
2
• DFU for bidets.
Inlet
• Clean running water used exclusively as a cooling medium in an
appliance, device or apparatus, may discharge into the drainage
system through the ____ side of a fixture trap.
• 
Fixture units
• The sizes of vent piping shall be determined from its length and the
total number of _____ connected thereto
4
• No more than ____ separate fixture shall be connected to or
discharged into any one grease trap.
Plumbing and Drainage Institute
• PDI
L
• Lighter than type K which is available in both rigid and flexible form.
Commonly used in residential water supply line and for radiant
heating installations.
True
• (F or F) shielded coupling joint, hubless cast iron soil pipe and molded
rubber coupling joints shall not be considered as slip joints.
275
• Minimum fixture unit loadings on building sewer piping (2% slope) for
203 mm (8 inch) building sewer.
11200
• Maximum fixture unit loadings on building sewer piping (2% slope) for
305 mm (12 inch) building sewer.
Drain board
• Traps for island sinks and similar equipment shall be roughed-in above
the floor and may be vented by extending the vent as high as
possible, but not less than the _____ height.
51
• Minimum trap diameter (mm) for clothes washers.
8
• Threads per 25.4 mm for 102 mm and larger pipe.
Non-potable water line
• In cases where it is impractical to correct individual cross-connections
in the domestic water line, the line supplying such outlets shall be
considered a ________.
True
• (True or False) The equipment, material and labor necessary for
inspections or tests shall be furnished by the person to whom the
permit is issued or by whom inspection is requested.