You are on page 1of 42

Department of Electrical and Computer Engineering C.U.

I ,
ATD Campus. 1
Simulation and Optimization of Splayed Heat Sink Using
COMSOL Software

Presenters
 Takbeer Zahid (FA18-EPE-012)

 Umar Rahman (FA18-EPE-015)

 Muhammad Rehan (FA18-EPE-166)

Supervisor Engr. Zulfiqar Khattak

Department of Electrical and Computer Engineering C.U.I ,


ATD Campus 2
Project Outline
o Objectives
o Introduction
o Modern Heat sink
o Splayed Heat sink
o Uses
o Literature Review
o Engineering Problem
o Methodology
o Block Diagram
o Proposed Solution
o Mathematical modeling
o COMSOL Software
o Project work-flow
o Optimization
 Objective function and constraints
o Results
o References

3
Objectives

 Simulation & thermal analysis of Commercial


Splayed Heat Sink using Comsol Multiphysics®
software
 Study & Implementation of Optimization tools for
modification and efficiency enhancement of splayed
Heat sink
 Comparison of results generated from commercial and
optimized splayed heat sink

Department of Electrical and Computer Engineering C.U.I ,


ATD Campus. 4
Introduction

o The heatsink is typically a metallic heat exchanger


which can be attached to a device releasing energy in
the form of heat

Department of Electrical and Computer Engineering C.U.I ,


ATD Campus 5
Splayed Heat Sink [4]

 Splayed heat sinks are relatively new derivatives of the standard pin fin heat
sink
 Unlike standard heat sink it contain an
array of vertically oriented pins that gradually bend outwards
 Curving the pins in this way increases the spacing
between them
 Surface area of heat sink remains same.

Department of Electrical and Computer Engineering C.U.I ,


ATD Campus 6
Uses
 It is used in Solar Inverter

 It is used for IC Cooling in an


electronics devices

 It is used in street light LED

 It is used in dc power supply

 It is used in Computer for IC cooling

Department of Electrical and Computer Engineering C.U.I ,


ATD Campus 7
Literature Review
Previously, the work done on Heat Sink was based on
`

 Height of fins
 Distance between fins
 Size of heat sink
 Angle shift between fins
Optimization for enhancing efficiency was performed on
basis of the angle shift of fins (i.e )

Department of Electrical and Computer Engineering C.U.I ,


ATD Campus 8
Engineering Problem

 Design and enhancing efficiency of Splayed


Heat Sink using optimization tools in
COMSOL Multiphysics Software

Department of Electrical and Computer Engineering C.U.I ,


ATD Campus
9
Methodology

 Designed CAD model (AUTOCAD)


 Import CAD model to COMSOL MultiPhysics
 Performing optimization to enhance efficiency
 Mathematical expressions & results

Department of Electrical and Computer


Engineering C.U.I, ATD Campus 10
Block Diagram

Department of Electrical and Computer Engineering


C.U.I , ATD Campus 11
Mathematical Modeling
Thermal resistance
Pressure drop
Where ,
Rth=Thermal resistance

ho=Heat Co-efficient ΔP=f


Ab=Area of base
N=Number of fins
Afin=Area

Reynold ‘s Number
Re=
=Density of air
Umax= maximum velocity
Dh=hydraulic diameter

Department of Electrical and Computer Engineering C.U.I,


12
ATD Campus
Proposed Solution

Optimizing commercial splayed heat sink on the basis of


parametric variations which are:
• Angle shift
• Fins diameter
• Material
• Size
Our main objective will be its optimization on the basis of
angle shift

Department of Electrical and Computer Engineering C.U.I ,


ATD Campus 13
COMSOL Software
 COMSOL Multiphysics
 GUI Based Software
 Modeling and solving of mathematical and designing problem
 Geometry, mesh, visualization and results.
 Optimization Interface available

Department of Electrical and Computer Engineering


C.U.I , ATD Campus 14
Project Workflow

Department of Electrical and Computer Engineering C.U.I ,


ATD Campus. 15
Optimization
 Optimization is a tool that you can use in conjunction with any existing COMSOL
Multiphysics Product.
 Term Optimization Means improving your COMSOL Multiphysics model
 This improvement involve four steps

 First, you define your objective function – a figure of merit that describes your
system
 Second, you define a set of design variables – the inputs to the model that you
would like to change
 Third, you define a set of constraints, bounds on your design variables, or operating
conditions that need to be satisfied
 Last, you use the Optimization Module to improve your design by changing the
design variables, while satisfying your constraints.

Department of Electrical and Computer Engineering C.U.I ,


16
ATD Campus
Objective function and constraints

Department of Electrical and Computer


Engineering C.U.I ATD Campus 17
Defined parameters

18
Department of Electrical and Computer Engineering C.U.I ATD Campus
Splayed Heat Sink Design (80 ° )

Department of Electrical and Computer Engineering C.U.I,

ATD Campus 19
Tunnel view

Department of Electrical and Computer Engineering C.U.I,


ATD Campus 20
Mesh plot

Department of Electrical and Computer Engineering C.U.I,


ATD Campus 21
Surface Temperature (Deg)

Department of Electrical and Computer Engineering C.U.I,


ATD Campus
Iso-surface Temperature (K)

Department of Electrical and Computer Engineering C.U.I


ATD Campus 23
Velocity slices

Department of Electrical and


Computer Engineering C.U.I ATD
Campus 24
Pressure

Department of Electrical and


Computer Engineering C.U.I ATD
Campus 25
Velocity streamline

Department of Electrical and Computer Engineering C.U.I,


ATD Campus 26
Thermal Resistance vs Velocity

Velocity Thermal
Resistance[k
/W]

5 0.098700

10 0.082200

15 0.070400

20 0.061700

25 0.049300

Department of Electrical and


Computer Engineering C.U.I ATD
Campus 27
Thermal resistance vs Heat Flux

Heat Flux[W] Thermal


Resistance[
k/W]
10 0.098700

30 0.082200

50 0.070400

70 0.061700

90 0.049300

Department of Electrical and


Computer Engineering C.U.I ATD
Campus 28
Thermal Resistance VS Heat coefficient :
Heat Thermal
Coefficient Resistance[
[W/ k/W]

10 0.0987

12 0.0822

14 0.0704

16 0.0617

20 0.0493

Department of Electrical and


Computer Engineering C.U.I ATD
Campus 29
Splayed Heat Sink Design (75 ° ) :

Department of Electrical and


Computer Engineering C.U.I ATD
Campus 30
Tunnel View

Department of Electrical and


Computer Engineering C.U.I ATD
Campus 31
Surface Temperature (Deg):

Department of Electrical and


Computer Engineering C.U.I ATD
Campus 32
Mesh plot

Department of Electrical and


Computer Engineering C.U.I ATD
Campus 33
Iso-surface Temperature (K)

Department of Electrical and Computer Engineering C.U.I,


ATD Campus 34
Velocity slices

Department of Electrical and 35


Computer Engineering C.U.I ATD
Pressure

36
Department of Electrical and Computer Engineering C.U.I ATD Campus
Velocity streamline:

37
Department of Electrical and Computer Engineering C.U.I ATD Campus
Thermal resistance vs Velocity:

Velocity Thermal
Resistance[k
/W]

5 0.094700

10 0.079200

15 0.068400

20 0.059700

25 0.047300

Department of Electrical and Computer Engineering


C.U.I ATD Campus 38
Thermal resistance vs heat flux:

Heat Flux[W] Thermal


Resistance[k
/W]

10 0.094700

30 0.079200

50 0.068400

70 0.059700

90 0.047300

Department of Electrical and


Computer Engineering C.U.I ATD
Campus 39
Thermal resistance vs heat coefficient

Heat Thermal
Coefficient Resistance[
[W/ k/W]

10 0.0947

12 0.0792

14 0.0684

16 0.0597

20 0.0473

Department of Electrical and Computer


Engineering C.U.I ATD Campus 40
References:
 https://www.radianheatsinks.com/heatsink/
 K. Nishino et al., 1996. Turbulence statistics in the stagnation region of an axisymmetric
impinging jet flow, Int. J. Heat Fluid Flow, 17, 193-201
 https://uk.rs-online.com/web/generalDisplay.html?id=ideas-and-advice/heatsinks-guide
 https://www.ijert.org/research/cfd-analysis-of-splayed-pin-fin-heat-sink-for-electronic-
cooling-IJERTV1IS10473.pdf
 Khattak, Zulfiqar, and Hafiz Muhammad Ali. "Air cooled heat sink geometries subjected
to forced flow: A critical review." International Journal of Heat and Mass Transfer 130
(2019): 141-161.]

Department of Electrical and Computer Engineering C.U.I ,


ATD Campus
41
.U.I ATD Campus
Department of Electrical and Computer Engineering C.U.I,
ATD Campus 42