The document discusses temperature and flow control of aircraft air conditioning and pressurization systems. It describes:
1) Two air conditioning system controllers that control temperature and airflow.
2) Pack and zone controllers that each have dual primary and secondary channels.
3) Pack controllers that modulate valves and flaps to control temperature and ram air inlet flap position during takeoff, landing, and below 70 knots.
4) Zone controllers that send lowest demand zone temperature signals to pack controllers.
The document discusses temperature and flow control of aircraft air conditioning and pressurization systems. It describes:
1) Two air conditioning system controllers that control temperature and airflow.
2) Pack and zone controllers that each have dual primary and secondary channels.
3) Pack controllers that modulate valves and flaps to control temperature and ram air inlet flap position during takeoff, landing, and below 70 knots.
4) Zone controllers that send lowest demand zone temperature signals to pack controllers.
The document discusses temperature and flow control of aircraft air conditioning and pressurization systems. It describes:
1) Two air conditioning system controllers that control temperature and airflow.
2) Pack and zone controllers that each have dual primary and secondary channels.
3) Pack controllers that modulate valves and flaps to control temperature and ram air inlet flap position during takeoff, landing, and below 70 knots.
4) Zone controllers that send lowest demand zone temperature signals to pack controllers.
CONDITIONING AND PRESSURIZATION CAPT. NATHANIEL DE LOS REYES AIR CONDITIONING TEMPERATURE AND FLOW CONTROL AIR CONDITIONING TEMPERATURE AND FLOW CONTROL
1. Temp and flow control
2 air conditioning system controllers I. Controls the temperature Airflow of the air conditioning system 2. System controllers Are I. Pack controllers II. Zone controllers Each system controllers are: I. Dual II. Primary channel controllers III. Secondary channel controllers AIR CONDITIONING TEMPERATURE AND FLOW CONTROL
1. Air conditioning system controllers
Controls I. Airflow of the pack by modulating the pack flow control valve 2. Pack controllers Controls I. Temperature of the pack II. By Modulating the position of the turbine bypass valve Ram air inlet flap Ram air inlet flap CLOSES I. During take off II. When take off power is set III. Landing IV. Landing gear struts are compressed V. Below or at 70 kts 3. Zone controllers Sends signals I. Lowest demand zone temp to the pack controllers AIR CONDITIONING TEMPERATURE AND FLOW CONTROL AIR CONDITIONING TEMPERATURE AND FLOW CONTROL
1. PACK FLOW selector
Used for: I. Adjusting the pack flow for the number of customers and external conditions AIR CONDITIONING TEMPERATURE AND FLOW CONTROL
HEAT EXCHANGE COOLING MODE
1. Heat exchange cooling mode When ACM (air cycle machine) fails 1. Due to compressor 2. Tubine seizure The affected pack reverts to heat exchanger cooling mode 1. Reduced pack flow