You are on page 1of 29

CE 37 - Engineering Utilities 1

ELECTRICAL DESIGN
PROPOSED TWO-STOREY RESIDENTIAL BUILDING

Presenter: Hosted By:


Princess Diane Maniacap Engr. Dennis Salboro
Agenda

• Floor Plan

• Illumination Design

• Lighting Layout Plan

• Convenience Outlets and Power Layout Plan

• Schedule of Loads

• One Line Diagram


• Materials and Labor Cost Estimate
PERSPECTIVE
GROUND FLOOR
PLAN
Total Floor Area: 200 sqm
SECOND FLOOR
PLAN
Total Floor Area: 200 sqm
ILLUMINATION
ILLUMINATION
Calculations

• Room Index: (L x W) / [Hm (L+W)]


• Utilization Factor, UF is determined from the room index then draw the value from the reflectance table.
• Number of Lamps: E x A / [F x UF x MF]
• Use 70% wall reflectance, floor reflectance 30% and 20 % ceiling reflectance
LIGHTING LAYOUT PLAN
Ground Floor Plan Second Floor Plan
LIGHTING OUTLETS LAYOUT PLAN
GROUND FLOOR PLAN

PANEL BOARD 1:
CIRCUIT 1: 8 - LED PIN LIGHTS (14 W)
CIRCUIT 2: 9 - LED PIN LIGHTS (14 W)
SWITCHES:
ONE GANG SWITCH-1 WAY: 1
TWO GANG SWITCH-1 WAY: 4
ONE GANG SWITCH-2 WAY: 1
SECOND FLOOR PLAN

PANEL BOARD 1:
CIRCUIT 3: 11 - LED PIN LIGHTS (14 W)
CIRCUIT 4: 14 - LED PIN LIGHTS (14 W)
SWITCHES:
ONE GANG SWITCH-1 WAY: 6
TWO GANG SWITCH-1 WAY: 3
ONE GANG SWITCH-2 WAY: 1
LIGHTING FIXTURES

LED PINLIGHTS FIXTURES 14 WATTS


SWITCH FIXTURES

1 GANG SWITCH - 1 WAY 2 GANG SWITCH- 1 WAY 1 GANG SWITCH - 2 WAY


CONVENIENCE OUTLETS AND POWER
PLAN
GROUND FLOOR PLAN

PANEL BOARD 1:
CIRCUIT 5 : 5 - 2- GANG C.O (360 W)
CIRCUIT 6 : 2 - GANG GCFI C.0 (360 W)
PANEL BOARD 2
CIRCUIT 1 : 1 - REFRIGERATOR (700 W)
CIRCUIT 2 : 1 - 2 HP, ACU (1492 W)
CIRCUIT 3 : 1 - 0.75 HP, ACU (559.5 W W)
SECOND FLOOR PLAN

PANEL BOARD 1:
CIRCUIT 7 : 6 - 2-GANG C.O (360 W)

PANEL BOARD 2
CIRCUIT 4 : 1 - 0.75 HP, ACU (559.5 W)
CIRCUIT 5 : 1 - 0.75 HP, ACU (559.5 W)
CIRCUIT 6 : 1 - 0.75 HP, ACU (559.5 W)
OUTLETS USED

2-GANG 3-PRONG
AIRCON OUTLET
CONVENIENCE
OUTLET

GCFI OUTLET REFRIGERATOR


OUTLET
SCHEDULE OF LOADS
PANEL BOARDS

PANEL BOARD 1:
• LIGHTING OUTLETS
• CONVENIENCE OUTLETS
PANEL BOARD 2:
• AIRCON OUTLETS
• LARGE APPLIANCES OBJECTS
SCHEDULE OF LOADS
PANEL BOARD 1

Note: All power outlets (CO,ACU,WH, MV) should have a grounding conductor equivalent to
the conductor size use on that particular green insulation
SCHEDULE OF LOADS
PANEL BOARD 2

SUMMARY OF LOADS

Note: All power outlets (CO,ACU,WH, MV) should have a grounding conductor equivalent to the conductor size use on that particular green
insulation
SINGLE LINE DIAGRAM
SINGLE LINE DIAGRAM
MATERIALS AND LABOR COST
ESTIMATE
MATERIALS AND LABOR COST ESTIMATE
MATERIALS AND LABOR COST ESTIMATE
MATERIALS AND LABOR COST ESTIMATE

GRAND TOTAL: PHP 359,911


THANK YOU