You are on page 1of 19

.

xxxx-51

..

LOGO ..
.. 2551

LOGO

. xxxx-51

. xxxx-51 :

500




. xxxx-51 :


1)
2)

3)


.
(1)
..
(2)
..










..

4)

5)

6)

. xxxx-51 :


1.
2.
3.
4.
5.
5.1.
5.2.


1
1
2
3
13
13
14

. xxxx-51

1.

1.1



1.2
1.2.1 NEMA MG1
500 600
NFPA 20

1.2.2 UL 1004

1.2.3 ANSI/NFPA 70
1.2.4 (Open and Enclosed
Motors)
1.2.5
1.2.6 NFPA 70
1.2.7




2.

(Modeling)
(Duty Cycle)
-1-



(Motor Size)
(Lug) (Fin)

B-A (Design B-A)


(locked-rotor current) 5
(Totally-enclosed Motor)

(Drip proof)

(Open Motor)
(Winding)
(Full Load Torque)

(Pull Up Torque)

(Locked Rotor Torque)

(Breakdown Torque)

3.

3.1
3.1.1
3.1.2 ANSI/ISA MC96.1-1982 - Temperature measurement thermocouples
3.1.3 IEC 60027-1 Letter symbols to be used in electrical technology
3.1.4 IEC 60027-4 Symbols for quantities to be used for rotating electrical machines
3.1.5 IEC 60034-14 Rotating electrical machines
3.1.6 NEMA MG1-1998 Motors and Generators
3.1.7 NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection, 2007 Edition
-2-

3.1.8
3.1.9
3.1.10
3.1.11
4.

NFPA 70, National Electrical Code


UL 50, Enclosures for Electrical Equipment
UL 1004, Standard for Electric Motors
UL 1004A, Fire Pump Motors

4.1.1 UL1004

4.1.2 Design B
NEMA MG1-1993
4.1.3 2

UL50

4.2
4.2.1
.


4.2.2

4.2.3
(Interrupting Capacity)


4.3
4.3.1
4.3.2 :) (Centrifugal Fire Pump

4.1

-3-

-
(Flexible Coupling)
-

-

)
-
-

-

4.4
4.4.1
)

)

)


)

4.4.2
4.4.2.1

4.4.2.2
4.4.2.3
105

-4-


()
()
110-120
120
200-208
208
220-240
240
254-277
277
244-480
480
550-600
600

1.
2.
3.
4.
5.
6.
7. Class 105(A0)
-
-
8. Class 120(E)
-
-
9. Class 130(B)
-
-
10. Class 155(F)
-
-
11. Class 180(H)
-
-
12.

-5-

60
65
65
65
65
65

108
117
117
117
117
117

65
75

117
135

75
85

135
153

85
95

153
171

110
120

198
216

125
135
125

225
243
225

13.
14. (Capacitors)
-
-
15.
16.
17.
18.

35

63

40
72
65
117
40 (72)

) Class A
35

)
35

)
65
) 65

) 5
)

4.4.2.4 (Thermocouples)
change-in-resistance

)
)
-6-

)
0.7937 (1/32 )
4.4.2.5
24-30 AWG
ANSI/ISA MC96.1
4.4.2.6

4.4.3 (Locked Rotor Test)


4.4.3.1

(380 50 )

()

( )

0.75
1.12
1.49
2.24
3.73
5.59
7.46
11.2
14.9
18.6
22.4
29.8
37.3
44.7
55.9
74.6
93.2
112
149

20
27
34
43
61
84
107
154
194
243
289
387
482
578
722
965
1,207
1,441
1,927

-7-

4.4.4 (Dielectric voltage-withstand test)


4.4.4.1
60
1,000
1 250
4.4.4.2
4.4.5 (Input test)
4.4.5.1
10
4.4.6 (Duty cycle test)
4.4.6.1
5


12
4.4.6.2

4.4.7 (Drip Test)
4.4.7.1

4.4.7.2 (Drip pan)

20 20
30
4.5

4.5.1
4.5.2
4.5.3
4.5.4
4.5.5
-8-

4.5.6
4.5.7
4.5.8
4.5.9
4.5.10

-9-


( 4.5)

xxx/xx


:
. xxxx-51

:
:
:
:

:
:

-10-

.
.)

( )
( 4.5)

xxx/xx


:
. xxxx-51

-11-

.)

5.

5.1
5.1.1
5.1.1.1




5.1.2
5.1.2.1

IEC 60027-1 IEC 60027-4
5.1.2.1.1
5.1.2.1.2 (serial number) (identification mark)




5.1.2.1.3

5.1.2.1.4 (machine code)
5.1.2.1.5
5.1.2.1.6 (IEC 60034-X /
) IEC 60034
IEC 60034
5.1.2.1.7
( IP) IEC 60034-5
5.1.2.1.8
()

P S
-12-

5.1.2.1.9

5.1.2.1.10
5.1.2.1.11
5.1.2.1.12
5.1.2.1.13
5.1.2.1.14
5.1.2.1.15
5.1.2.1.16
5.1.2.1.17

(P) (S)
( /)


S1









40 ,
25

( 1,000
)


30



IEC 60034-8
X/Y
X-Y ( IEC 61293)

5.1.2.1.18

5.1.2.1.19
5.1.2.1.20

5.1.2.1.21

5.1.2.1.22
5.1.2.1.23

5.1.2.1.24

5.1.2.1.25

-13-

5.2
: . 866-2532
: . 867-2532
Standard for Centrifugal Stationary Pumps for Fire-Protection Service, UL 448

-14-