You are on page 1of 4

NWFP ON FARM WATER MANAGEMENT

OFFICE OF THE DISTRICT OFFICER MANAGEMENT


Design Sheet for Pipe Watercourses
Watercourse No.

KUND KHUSHALA

Village

Source:
Survey Data
Elev of Source:

KHWAR (LIFT THROUGH PUMP)

Union Council: DATTA

Rd
0
30
60
90
120
156

99.12

Elev of Heighest Field:


Total Length

106.7
156

Design Data: (Meters)


Dia of Pipe: (d)
Pipe Material #
Hazen Willium Coeff:
Maximum Pressure (m)
Mininmum Pressure (m)
Maximum Velocity (m/s)
Mininmum Velocity (m/s)
Area of Flow (A)
Wetted Perimeter (P)
Hydraulic Radius (R)
Available Slope (S)
Available Discharge (lps)

0.08
1
140
70
0
4.5
0.4
0.005
0.24
0.021
-0.05
7.4

NSL
99.18
100.66
102.12
103.78
104.84
106.78

KHUSHALA

(inches)

Max
Crown
Head
Lvl
(elev m)

Design Reach
Drop
Invert Length
(m)
lvl (m)
(m)

124.12
122.888
121.656
120.423
119.191
117.713

99.18
101.28
103.38
105.48
106.98
108.42

99.2562
101.356
103.456
105.556
107.056
108.496

30
30
30
30
36

dia of
Pipe Slope
(mm)
76.2
76.2
76.2
76.2
76.2
76.2

-0.07
-0.07
-0.07
-0.07
-0.05
-0.04

3
Smooth &
Straight Steel
(Smooth & Straight Pipe, Aluminium, Cast Iron,
PVC, Concrete, Riveted Steel, Old Cast Iron,
Corroded Cast Iron)

Inner
Area of
Pipe (A)

Wetted
Perimeter (P)

Hydraulic
Radius
(R)

0.24
0.24
0.24
0.24
0.24
0.24

0.021
0.021
0.021
0.021
0.021
0.021

0.005
0.005
0.005
0.005
0.005
0.005

Hazen
Willium
Coeff:
140
140
140
140
140
140

Discharge (Q)
Vel (V)

K
m3/s

2.3517
2.3517
2.3517
2.3517
1.9479
1.7191

0.0074
0.0074
0.0074
0.0074
0.0074
0.0074

LPS
7.4
7.4
7.4
7.4
7.4
7.4

Head loss Head loss


Total
due to
(others)
Pressure
Head loss
friction m 15% of
(m)
(m)
(m)
hf

1.21E+10
0
1.21E+10
1.0715
1.21E+10
1.0715
1.21E+10
1.0715
1.21E+10
1.0715
1.21E+10
1.2857
Total Head Loss (m)

0
0.160725
0.160725
0.160725
0.160725
0.192855

0
1.232225
1.232225
1.232225
1.232225
1.478555
6.407455

Available Head (m)


Result :

Select Pump

-7.59

Selected Pump (hp):

8 HP

Pump & Motor requirement:


1.
2.
3.
4.
5.
6.
7.

Suction Head (m):


Delivery Head (m):
Total Head Loss (m):
Total Head Required (m):
W.H.P = QH/76 (hp):
Pump Eff %:
B.H.P (hp) =

6
7.59
6.4075
19.997
1.9471
25.00%
7.7885

24.9019
21.56968
18.23745
14.90523
12.173
9.254445

Pressure
Warning

"(Q/
Velocity
(0.8492XCX
Warning
(S)^(0.56)))

0.0003
0.0003
0.0003
0.0003
0.0003
0.0004

"A x
R^(0.63)

0.0004
0.0004
0.0004
0.0004
0.0004
0.0004

Differen
ce

0.00
0.00
0.00
0.00
0.00
0.00

Size Check

ok
ok
ok
ok
ok
ok

Remarks

O/L for Br A
O/L for Br B

1
2
3
4
5
6
7
8

Pipe Material C
Smooth & Strai
Aluminium
Iron (Cast Iron
PVC
Concrete
Riveted Steel
Old Cast Iron
Corroded Cast

Pmin
140
130
130
150
120
110
100
80

Pmax
0
0
0
0
0
0
0
0

Vmax
16
6
6
6
3
6
4
3

Vmin
4.5
3
3
3
2.5
3
2.5
2.5

0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4

Elevation

DISTRICT OFFICER WATER MANAGEMENT MANSEHRA (SHAH PUNJA PIPE W/C)

NSL
Invert Lvl
Crow n Lvl
Pressure Head
Highest Field

20

40

60

80

RD

100

120

140

160