Special Confining Reinforcement in Rectanngular Section

Cover to Reinforcement

40

mm

Fck

40

N/mm2

Fy

415

N/mm2

Dia of Hoop

mm

Area of Hoop Provided

50.27

mm2

Size

675
Ag' = 455625

Size of Core

611

mm2
611

Ak' = 373321
Arrangemnt of Hoop Type

675

mm2

Type - 1 : Single Hoop

Type - 2 Single Hoop with Croos Tie in Middle


h' Longer Dimension of Hoop
a) 305.5
b) 305.5
Larger of above, But Max. 300 mm 300
s' Pitch of Hoope
a) 1/4 of Min Dimension

168.75 mm

b)

100 mm
Pitch = Lesser of (a) &( b)

100 mm

Ash = 0.18 * S * h * ( Fck/Fy) ( Ag/Ak - 1)


Area of Hoop Required

114.75 mm2

Area of Hoop Provided

50.27 mm2

Increase
Dia of Hoop

Special Confining Reinforcement in Circular Section


Cover to Reinforcement

40

mm

Fck

20

N/mm2

Fy

415

N/mm2

Dia of Hoop

mm

Area of Hoop Provided

50.27

mm2

Size Circular Column

300

mm

Ag' = 70685.8
Diameetr of Core - Dk

mm2

236
Ak' = 43743.5

mm2

s' Pitch of Hoope


a) 1/4 of Min Dimension

75 mm

b)

100 mm
Pitch = Lesser of (a) &( b)

75 mm

Ash = 0.09 * S * Dk * ( Fck/Fy) ( Ag/Ak - 1)


Area of Hoop Required

47.28 mm2

Area of Hoop Provided

50.27 mm2
OK