You are on page 1of 3

StruMat Testing

1. FIELD REPORT: PLATE THICKNESS MEASUREMENTS FOR PENSTOCK PIPES


AFTER SAND BLASTING
2. CLIENT:VS HYDRO KENYA LTD
3. PROJECT:GURA HYDRO POWER
4. LOCATION:MIRIINI SITE
5. DATE:17/12/2015
6. PIPE ID

PN1-TRIAL

7. EQUIPMENT NAME

MMX-6 MULTIMODE ULTRASONICS THICKNESS

& SERIAL NO.


8. PROCEDURE:

GAUGE S NO.62030
-

TEST RESULTS
POINT NO.
PLATE THICKNESS(mm)

9.56

9.6

9.46

9.43

9.48

9.52

TEST POINTS SKETCH

TESTS DONE BY:


SIGN:
NAME: SIMON G. WAHOME

Page 1 of 3

StruMat Testing
1. FIELD REPORT: PLATE THICKNESS MEASUREMENTS FOR PENSTOCK PIPES
AFTER SAND BLASTING
2. CLIENT:VS HYDRO KENYA LTD
3. PROJECT:GURA HYDRO POWER
4. LOCATION:MIRIINI SITE
5. DATE:24/12/2015
6. PIPE ID

PN2

7. EQUIPMENT NAME

MMX-6 MULTIMODE ULTRASONICS THICKNESS

& SERIAL NO.


8. PROCEDURE:

GAUGE S NO.62030
-

TEST RESULTS
POINT NO.
PLATE THICKNESS(mm)

9.53

9.6

9.56

TEST POINTS SKETCH

TESTS DONE BY:


SIGN:
NAME: SIMON G. WAHOME

Page 2 of 3

StruMat Testing
1. FIELD REPORT: PLATE THICKNESS MEASUREMENTS FOR PENSTOCK PIPES
AFTER SAND BLASTING
2. CLIENT:VS HYDRO KENYA LTD
3. PROJECT:GURA HYDRO POWER
4. LOCATION:MIRIINI SITE
5. DATE:24/12/2015
6. PIPE ID

PN3

7. EQUIPMENT NAME

MMX-6 MULTIMODE ULTRASONICS THICKNESS

& SERIAL NO.


8. PROCEDURE:

GAUGE S. NO.62030
-

TEST RESULTS
POINT NO.
PLATE THICKNESS(mm)

9.65

9.65

9.77

9.84

9.78

9.44

TEST POINTS SKETCH

TESTS DONE BY:


SIGN:
NAME: SIMON G. WAHOME

Page 3 of 3