STATISTICAL DATA (F.M. TRANSMITTERS)
FOR THE MONTH OF OCTOBER 2013

F.M. I F.M. II
BREAKDOWNS + SHUTDOWNS
( Rainbow) (Gold)
Numbers 00 00
Major
B/D Duration 00:00 00:00
due to
GEAR Numbers 00 00
Minor
Duration 00:00 00:00
Numbers 00 00
Major
B/D Duration 00:00 00:00
due to
POWER SUPPLY Numbers 6 1
Minor
Duration 00:08 00:01
Numbers 00 00
Major
B/D Duration 00:00 00:00
due to
O/C Numbers 02 3
Minor
Duration 00:03 00:05
Numbers 0 0
Major
RF Shutdown Duration 00:00 00:00
(SD) Numbers 2 2
Minor
Duration 00:03 00:03
Numbers 0 0
Total BD + SD Major
Duration 00:00 00:00
Numbers 4 6
Minor Duration 00:06 00:09

RF Shutdown = SD

2
STATISTICAL DATA
FOR THE MONTH OF OCTOBER 2013

FM I FM II
MONTHLY FIGURES (10KW) (R&S) (20 KW) (Nautel)
Hours of Testing 00:00 00:00
WORKING OF
Hours of Programme 744:00 744:00
TRANSMITTER
Total Working Hours 744:00 744:00
B/D due to Gear 00:00 00:00
Percentage 0.00% 0.00%
B/D due to P/S 00:00 00:01
Percentage 0.00% 0.0022%
B/D due to O/C 00:03 00:05
Percentage 0.0067% 0.0112%
SD 00:06 0:03
Percentage 0.0067% 0.0067%
Total (BD+SD) 00:06 00:09
Percentage 0.0134% 0.02016%

FM I FM II
PROGRESSIVE TOTAL (10KW) (R&S) (20 KW) (Nautel)
Hours of Testing 00:00 00:00
WORKING OF
Hours of Programme 5136:00 5136:00
TRANSMITTER
Total Working Hours 5136:00 5136:00
B/D due to Gear 00:00 00:00

Percentage 0.00% 0.00%


B/D due to P/S 00:14 00:47
BREAK DOWNS/ Percentage 0.0045% 0.01525%
INTERRUPTIONS\ B/D due to O/C 00:55 00:63
SHUTDOWN Percentage 0.01784% 0.02044%
SD 32:08 32:03
Percentage 0.6256 % 0.6240%
Total(BD+SD) 33:17 33:47
Percentage 0.6480% 0.6730 %
3
BREAKDOWN IN RESPECT OF FM TRANSMITTER
FOR THE MONTH OF OCTOBER2013

FM I TRANSMITTER (102.6 MHz) (RAINBOW)


B/D due to GEAR
B/D Timing Duration
Date Cause
From To Hours Minutes

Total 0 0

B/D due to POWER SUPPLY FAILURE


B/D Timing Duration
Date Cause
From To Hours Minutes
-
-

-
-
-
Total

B/D due to OTHER CAUSES


B/D Timing Duration
Date Cause
From To Hours Minutes
22/10/2013 1557 1559 0 2 STL failure from BH end
29/10/2013 1501 1502 0 1 STL failure from BH end
Total 0 3

Momentary Interruptions
Date MI Timing Cause
1/10/2013 1638, 1714 PSF
11/10/2013 1025, 1030, 1157, 1213 STL failure

RF Shut down
B/D Timing Duration
Date Cause
From To Hours Minutes
09/10/2013 0102 0103 0 1 RF Shutdown
09/10/2013 0327 0329 0 2 RF Shutdown
0 0 RF Shutdown
Total 0 3
4
FM II TRANSMITTER (106.4 MHz) (GOLD)
B/D due to GEAR
B/D Timing Duration
Date Cause
From To Hours Minutes
-

Total -

B/D due to POWER SUPPLY FAILURE


B/D Timing Duration
Date Cause
From To Hours Minutes
17/10/2013 1758 1759 00 1 PSF

Total 00 1

B/D due to OTHER CAUSES


B/D Timing Duration
Date Cause
From To Hours Minutes
20/10/2013 1815 1816 0 1 No programme from NBH
22/10/2013 1557 1559 0 2 No programme from NBH
27/10/2013 2027 2029 0 2 No programme from NBH
Total 5

Momentary Interruptions
Date MI Timing Cause
1/10/2013 1638, 1714 PSF
4/10/2013 1807, 1813, PSF
25/10/2013 1025, 1030, 1157, 1213 PSF
30/10/2013 1811, 1817 STL failure

RF Shut down
B/D Timing Duration
Date Cause
From To Hours Minutes
09/10/2013 0102 0103 0 1 RF Shutdown
09/10/2013 0327 0329 0 2 RF Shutdown

Total 0 3
5
STATUS OF DG I(For FM RAINBOW)
FOR THE MONTH OF OCTOBER 2013

HMR OF D.G. Set as on 31/10/2013 365


HMR OF D.G. Set as on 30/09/2013 359
For Testing 1Hrs 51mins
D.G. Set running
during the month of For Transmission 4Hrs 44mins
OCTOBER 2013 Total Running 6Hrs 35mins
Balance in tank as on 1/10/2013 56Litres
Added in tank during OCTOBER 100*
DIESEL Balance in tank as on 31/10/2013 104Litres
POSITION
Consumed during OCTOBER 52Litres
Average Consumption 8 Litres/Hour

STATUS OF DG II (For FM GOLD)


FOR THE MONTH OF OCTOBER 2013

HMR OF D.G. Set as on 31/10/2013 413


HMR OF D.G. Set as on 30/09/2013 407
For Testing 1Hrs 51mins
D.G. Set running
during the month of For Transmission 4Hrs 44mins
OCTOBER 2013 Total Running 6Hrs 35mins
Balance in tank as on 1/10/2013 108Litres
Added in tank during OCTOBER 100*
DIESEL Balance in tank as on 31/10/2013 155Litres
POSITION
Consumed during OCTOBER 53Litres
Average Consumption 8.1Litres/Hour

*200 litres taken from IGNOU

6
Important Work Done During The Month

Sr.No Date Work Done


1. 3/10/2013 In the FM Rainbow (R&S) transmitter, one PA having
serial no. 102443 after getting repaired was installed.The
PA and the transmitter are working OK.
2 7/10/2013 There were frequent PA failures in the FM Rainbow
transmitter. The RF cable in output stage of PA-2 and
PA-3was found burnt at one side. The same was re-
soldered, after which the transmitter started working ok.
3. 11/10/2013 One defective PA having serial no. 102351 after getting
repaired was installed in the FM Rainbow
transmitter(R&S). The transmitter is working ok.
4. 25/10/11 There was non-availability of signal in the C-band
receivers. The LNBC in the 6.2m PDA was defective. The
same was replaced.The LNBC polarization was also fine
tuned with the servo control. Now C-band reception is
normal.