ASSAM TYPE BUILDING-SPECIFICATION-‘A’

(FUNCTIONAL / RESIDENTIAL)

1. Foundation : 75 mm thick prop 1:3:6


2. Plinth beam : As per design (R.C.C.).
3. Plinth Wall
225 mm thick 1st class brick works in cement mortar in prop 1:5 and
a) Outer wall 15mm thick cement plaster in prop 1:6 on exposed faces with neat cement
slurry finish.
b) Inner wall 112 mm thick 1st class brick work in cement mortar in prop. 1:5
Providing and laying 25mm thick damp proof course with cement concrete
in prop 1:1.5:3 with graded stone aggregate of 10 mm down nominal size
4. D.P.C. including providing approved damp proof admixture in proportion as
recommended by the manufacturer including curing etc . complete as
directed.
5. Post : 130 mm x 130 mm R.C.C. as per design.
: With R.C.C. foundation as per design Depth of foundation 1.0m from
6. Foundation
ground level.
65mm thick cement concrete flooring with 50 mm under layer of cement
7. floor
concrete in prop 1:3:6 and 15 mm thick cement concrete topping in jprop
1:1:2 over one flat brick soling/150mm thick stone soling.
112mm thick 1st class brick nogged wall in cement mortar prop 1:5 from
plinth upto post plate cement plaster 15mm thickness on outside face, 10 mm
8. Wall thick on inside face in prop. 1:5 including Distempering over plaster of paris
or wall putty. Outer wall will be finished with cement wash/weather coat
with cement primer..
9.
Window/Clerestory As per Architectural design.
window :
10. Doors : As per Architectural design.
11. Roofing : 0.63 I.S. thickness (in mm) roofings over undressed wooden/timber truss.
12. Ceiling : A.C. Board/ Gypsum Board with painting.
C.C. apron jwith drain, cupboard, chowkats, door and window leaf to be
13. Miscellaneous painted with one coat of primer and two coatsj of enamel paints of
approved shade.
14. Height of
600- 750mm for all buildings.
plinth.

15. Height of : 3050-3600 mm


building