You are on page 1of 13

Electronic Control Systems

Error Code Table

iFlex5 (C Structure)

System programs: LI5G V 1.04 or later


Parts list No.: see iFlex5 system software

1. Error Codes displayed on the SLI Console

Error Code Error Cause Elimination


E01 Fallen below radius  Fallen below the minimum  Luff down the boom to a
range or angle radius or gone past the radius or angle specified in
range exceeded maximum angle specified in the load chart.
the respective load chart
due to luffing up the boom
too far
E02 Radius range  Gone past the maximum  Luff up the boom to a radius
exceeded or fallen radius or fallen below the or angle specified in the load
below angle range minimum angle specified in chart.
the respective load chart
due to luffing down the
boom too far
E03 Non-permitted  The slewing zone with load  Slew to permitted area
slewing zone (no is not permitted
load area)
E04 Operating mode not  A non existing operating  Set the correct operating
acknowledged or mode has been selected mode for the operating state
non permitted in question
slewing zone
 The boom is in a non-  Slew the boom to a
permitted slewing zone permitted area.

1 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

Error Code Error Cause Elimination


E05 Prohibited length  Boom has been extended  Extend/retract boom to the
range either too far or not far correct length
enough, e.g. if it is
prohibited to go beyond a
certain maximum boom
length or with load curves
for jibs where the main
boom has to be extended to
a certain length
 Length sensor adjustment  Retract boom. Check the
has changed, e.g. the cable prestress of the cable reel
slid off the length sensor (cable must be taut). Open
reel. the length sensor and
carefully turn the length
sensor pot counterclockwise
until the detent by means of
a screw driver
 Clutch between length  Replace the complete clutch
sensor pot and drive is including drive wheel and
defective adjust length sensor pot as
described above
E06 Radius range  Maximum radius as  Luff the jib to a radius or
exceeded or fallen specified in the load chart angle specified in the load
below angle range exceeded or fallen below chart.
with luffing jib minimum angle due to
operation luffing down the luffing jib
too far
E07 Overload relais  relais = overload active and  check cable to overload
check CU input 20 = on relais and CU input 20
 relais = no overload and CU  check relais
input 20 = off  check CU input 20
 PDB variable invalid  reset system
 emergency stop caused by  reset system
system software

2 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

Error Code Error Cause Elimination


E11 Fallen below lower  Length potentiometer is  Replace length
limit value for defective potentiometer
measuring channel
"length main boom"
 Electronic component in the  Replace sensor unit
measuring channel is
defective
E12 Fallen below the  Pressure transducer is  Replace pressure
lower limit value in defective. transducer
the measuring
channel "pressure
piston side"

 Electronic component in the  Replace sensor unit


measuring channel is
defective.
E13 Fallen below lower  refer to E12  refer to E12
limit value in the
measuring channel
"pressure rod side"
E14 Fallen below lower  Force transducer defective  Replace force transducer
limit value in  Electronic component in the  Replace sensor unit
measuring channel measuring channel is
"force" defective.

E15 Fallen below lower  Angle potentiometer  Replace angle sensor


limit value in defective
measuring channel
"angle main boom"

 Electronic component in the  Replace sensor unit


measuring channel
defective.

3 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

Error Code Error Cause Elimination


E16 Fallen below lower  Angle potentiometer  Replace angle sensor
limit value in defective
measuring channel
"angle 2"

 Electronic component in the  Replace sensor unit


measuring channel
defective.
E17 Fallen below lower  Length potentiometer  Replace length sensor.
limit value "length defective
telescope I (+II)"

 Electronic component in the  Replace sensor unit


measuring channel defective
E18 Front outrigger  Front outrigger overloaded 
overloaded

E1A Fallen below lower  Cable between the central  Check cable as well as
limit value in unit and the slewing angle plugs, replace, if need be.
measuring channel sensor defective or loose.
"slewing angle 1". Water inside the plug of the
angle sensor
 Slewing angle potentiometer  Replace slewing angle
is defective sensor
 Electronic component in the  Replace sensor unit
measuring channel defective
E1B Fallen below lower  refer to E1A  refer to E1A
limit value in
measuring channel
"slewing angle 2"
E1C Fallen below lower  Angle potentiometer  Replace angle sensor
limit value in defective
measuring channel
"luffing jib angle"
 Electronic component in the  Replace sensor unit
measuring channel
defective.
E1E Fallen below lower  Wind speed sensor  Replace windspeed sensor
limit value in defective
measuring channel  Not connected  Check cable
"wind speed"

4 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

Error Code Error Cause Elimination


E21 Upper limit value in  refer to E11  refer to E11
measuring channel
"main boom length"
has been exceeded.
E22 Upper limit value in  refer to E12  refer to E12
measuring channel
"pressure piston
side" has been
exceeded
E23 Upper limit value in  refer to E12  refer to E12
measuring channel
"pressure rod side"
has been exceeded.
E24 Upper limit value in  refer to E14  refer to E14
measuring channel
"force" has been
exceeded.
E25 Upper limit value in  refer to E15  refer to E15
measuring channel
"main boom angle"
has been exceeded.
E26 Upper limit value in  refer to E16  refer to E16
measuring channel
"angle 2" has been
exceeded.
E27 Upper limit value in  refer to E17  refer to E17
measuring channel
"length telescope I
(+II) has been
exceeded.
E2A Upper limit value in  refer to E1A  refer to E1A
measuring channel
"slewing angle 1"
has been exceeded
E2B Upper limit value in  refer to E1A  refer to E1A
measuring channel
"slewing angle 2"
has been exceeded
E2C Upper limit value in  Angle potentiometer  Replace angle sensor
measuring channel defective
"luffing jib angle"
has been exceeded
 Electronic component in the  Replace sensor unit
measuring channel
defective.
E2E Upper limit value in  refer to E1E  refer to E1E
measuring channel
"wind speed” has
been exceeded

5 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

Error Code Error Cause Elimination


E31 Error in the system  The system program file is  Upload valid system
program defective. software

 Flash-EPROM defective  Replace central unit


E37 Error in the logical  System program file is  Upload valid system
program flow defective software

 Flash-EPROM defective  Replace central unit


E38 System program  The system program in the  Upload valid system
and crane data file LMI does not match to the program file or the valid
do not match. programming in the crane crane data file
data file
E39 System program  The system program in the  Upload valid system
and load chart file LMI and the programming in program file or the valid load
do not match the load chart file do not chart file
match.
E43 Error in the  Write/read memory (RAM)  Replace central unit
write/read memory, or central unit defective.
(RAM)
E47 Error in the  The CRC sign of the  Restart the LMI
monitored write/ monitored write/read
read memory. memory is wrong

The CRC  The buffer battery is  Replace buffer battery on


verification of the decharged (< 2V at 1kOhm). the central unit.
monitored
write/read memory
provides an  Central unit defective.  Replace central unit
incoherent result
E51 Error in the crane  No valid data in the crane  Upload valid crane data file
data file data file.

 Flash-EPROM defective  Replace central unit


E52 Error in load chart  No valid data in the load  Upload valid load chart file
file. chart file

 Flash-EPROM defective  Replace central unit


E56 Error in crane data  No valid data in the crane  Restore or upload valid
file. data file during calibration. crane data file

 Flash-EPROM defective  Replace central unit


E57 Error in serial crane  Calibration data file does not  Upload calibration data file
data file. contain valid data.

 Flash-EPROM defective  Replace central unit

6 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

Error Code Error Cause Elimination


E61 Error in the CAN  CAN Bus cable between the  Check the connection
bus data transfer for central unit and the sensor between the central unit and
all CAN units unit defective or not the sensor units
connected.
 Can bus port in the central  Replace the central unit
unit defective
 Short circuit in a CAN Bus  Replace Can Bus cable
cable
E62 Error in the can bus  Cable between the central  Check the cable to the
data transfer of the unit and the sensor unit sensor unit
pressure transducer defective.
sensor unit
 Can bus port in the central  Replace the central unit
unit defective
 Can bus port in the sensor  Replace the sensor unit
unit is defective
 Sensor unit is defective  Replace the sensor unit
E63 Error in the can bus  The analog values of the  Replace the sensor unit
pressure transducer sensor unit are invalid
sensor unit
E64 Error in the can bus  See E62  See E62
data transfer of the
length/angle sensor
unit
E65 Error in the can bus  See E63  See E63
length/angle sensor
unit
E66 Error in the can bus  See E62  See E62
data transfer of the
2nd length/angle
sensor unit
E67 Error in the can bus  Invalid can message CAN  Check can source
message CAN repower input  Disable DGA 2.13, bit1
repower
E69 Error in the can bus  Invalid can message  Check can source
message CE2010 CE2010 input  Disable CE2010 input
DGA2.2
E80 Error in the slewing  The difference between the  Check the slewing
angle measurement average of the slewing angle potentiometer adjustment
and one of the wipers of the
slewing potentiometer is out  Replace slewing angle
of the tolerance sensor
E82 Error boom control  The boom control task is not  Restart the system
task running  Load the boom control task
E84 Wrong rigging  The selected rigging  Select another rigging
condition. condition is not contained in condition
the crane data file.
 Check the programming in
the crane data file.

7 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

E85 Error in the radius  The computed radius is too  Check the programming in
determination small (negative deflection) the crane data file.

E89 Operating mode  The operating mode on the  Select operating mode
switchover with console has been switched without load on the boom
load. over with the boom loaded.

8 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

Error Code Error Cause Elimination


E91 No data trans-  24 V supply of the console is  Check 24 V at terminal X1 of
mission form the interrupted the console electronics
console to the
central unit
 Interruption or accidental  Check the connection
ground in the line between console electronics - central
console electronics and unit. In case of an accidental
central unit ground, the transmitter
module of the console
electronics might be
damaged. Therefore,
replaces the console
electronics.
 Transmitter/receiver module  Exchange console
is defective electronics or LMI main
board resp.
E92 Error in the data  Loose connection in the line  Check the connection
transmission from between console electronics between console electronics
console to central and central unit and central unit
unit  Transmitter/receiver module  Exchange console
is defective electronics or LMI main
board resp.
E93 Error in the data  refer to E92  refer to E92
transmission from
the central unit to
the console

9 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

Error Code Error Cause Elimination


E94 No data trans-  Interruption or accidental  Check line to the console (in
mission from the ground in the line central case of accidental ground,
central unit to the unit – console replace console electronics,
console too).
 5 V supply of the computer  Check connection to the
in the central unit is missing power unit
 5 V supply is too low  Exchange the LMI main
board
 Transmitter/receiver module  Replace console electronics
is defective or LMI main board
 Computer module is  Replace processor board.
defective
 Electro-magnetic  Eliminate the source of
interferences (e.g. when interferences by inverse
switching contactors or diodes or varistors.
valves)
E95 Error in the console  The console File is  Replace the console File
File defective.
E96 Error in the internal  The CPU of the console is  Replace the CPU of the
RAM of the console. defective. console

 The console main board is  Replace the console main


defective. board.
E97 Error in the external  The external RAM of the  Replace the external RAM
RAM of the console console is defective. of the console.

 The console main board is  Replace the console main


defective. board.
E98 LMI watchdog  LMI processing time limit  Reset system
activated exceeded  Connect PC terminal and
watch error messages
EAB Short circuit in the  Short circuit in the A2B  Replace A2B switch
A2B switch circuit switch

 Short circuit in the cable to  Replace cable to the A2B


the A2B switch switch
EAC A2B switch circuit  Disconnected cable in the  Connect or replace cable in
disconnected A2B switch the A2B switch

 Disconnected cable to the  Connect or replace cable to


A2B switch the A2B switch
EAD No valid A2B switch  Sensor wrong function  Replace A2B switch
status
 CAN bus delay  Replace cable to the A2B
switch
EBB OMS outrigger  Outrigger retracted by one  Reselect an operating mode
retracted by one position with the changed outrigger
position position
 Restore outrigger to it’s
correct position

10 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

EBC OMS outrigger  Outrigger retracted by two  Reselect an operating mode


retracted by two positions with the changed outrigger
positions position
 Restore outrigger to it’s
correct position
EBD OMS outrigger  Sensor ‘string’ defective  Check ‘string’ adjustment
position sensor  Cable between the central  Connect or replace cable to
error unit and the sensor unit the position sensor
defective.
 Sensor unit is defective  Replace position sensor
EC0 Prohibited area  Boom is about to collide with  Move boom to permitted
the engine hood, switch off area

 Check values in the data


prom DGA 11.5.
EC1 Approaching  Boom is about to collide with  Move boom to permitted
prohibited area the engine hood, prewarning area

 Check values in the data


prom DGA 11.5.
EC2 Angle range of  Luffing jib is raised too far  Luff down the jib to a angle
luffing jib exceeded specified in the load chart.
EDA Datalogger write  Datalogger not connected  Check CAN bus connection
error  No power supply  Check power supply
 Wrong Dosdrive status  Connect PC terminal and
Refer to Dosdrive status list
 Temporary: Press horn quitt
button to work without
datalogger
EDB Datalogger setup  Setup of the datalogger is  transfer data and setup
error cleared (ser. crane data file datalogger again
or battery buffered RAM)  temporary: Press horn quitt
button to work without
datalogger
EDC Datalogger  datalogger processing time  Reset system
watchdog activated limit exceeded  Connect PC terminal and
watch error messages
EDD Battery empty  Battery check detected a  change batterie, after this
low voltage of the battery setup of RTC
 Temporary: Press horn quitt
button to work without
datalogger
EDE Record lost  Not possible to save data Message disappears after a
because other task saves few seconds
data at the same time
EDF Flash block full  Not possible to save any Message disappears after a
more data few seconds
EE0 Timebase invalid  The real time clock is in an  Setup of Time and date
invalid state
EFD LMI Watchdog  a funktion needs more than Message disappears after a
extra time 0.5 sec, e.g. Flash PROM few seconds
write

11 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

Note:
If an error message is displayed which is not contained in above list, please contact the
competent PAT service department.

2. additional error codes, only for datalogger


EA1 A2B open Hook position at upper limit Hook position downwards
EA2 Overload utization > 100% Reduce Load moment

12 von 13
© 2010 Hirschmann Automation and Control GmbH · D-76275 Ettlingen · Hertzstr. 32 - 34 ·  ++49 (0) 7243 709-0 · FAX ++49 (0) 7243 709-3141
Err_LI5G.doc /12.02.2013/ Rev.: 02
Electronic Control Systems

3. LED Colour Codes


The bicolor LED on the central unit is used as a raw diagnostic information about the system
status. It can be useful in the case that the iflex refuses terminal communication - otherwise the
terminal is a much more powerful diagnostic tool.

During initialization (after reset) the LED shows some of the initialization steps, so if the reset
procedure hangs, it is easier to find out where. The cycle is:
 RESET: red+small red (for approx 5 us)
 Wait for RAM: green (for approx 200 ms)
 Clear RAM: yellow (for approx 1 s)
 CRC-Check System program: light yellow (2.5 s)
 Init RS232/RS485 : yellow (1 s)
 Start RTOS: green (0.5 s)

After start of RTOS the LED toggles all 1 sec between dark/green/yellow/red.

So you can detect


- is the power supply ok?
- is the iflex in the reset procedure, hanging somewhere or is the Operating system running?

You cannot be sure if the LED shows running Operating system that all necessary tasks of the
System program are running correct, too. That has to be made sure via terminal commands.

3. Terminal Text
Error messages and status messages are displayed on the terminal in plain text.

13 von 13