You are on page 1of 16

V.

DATA PENGAMATAN
Aliran co current
Fluida Panas Fluida Dingin
Laju Fluida T masuk T Keluar Laju Fluida T masuk T Keluar
(L/min) (oC) (oC) (L/min) (oC) (oC)
2 50 45,7 1 17,7 32,2
3 49,1 46,2 1 18,3 33,2
4 48,3 46,1 1 19,4 33,7

VI. PERHITUNGAN
6.1. Aliran Co-Current Untuk Laju Fluida Panas (2 L/min) dan Fluida Dingin (1 L/min)
3,28
Diketahui L = 1,37 m x 1 𝑚 = 4,51 feet

HE berbentuksilinder ( ½ , ¾ )
 annulus = ¾ mch, sch = 40
1 ft
 OD : 1,05 inch x 12 𝑖𝑛𝑐ℎ = 0,0875ft

1 ft
 ID : 1,824 inch x 12 𝑖𝑛𝑐ℎ = 0,0687 ft

 Inner pipe = ½ inch, sch


1 ft
 OD : 0,84 inch x 12 𝑖𝑛𝑐ℎ = 0,07ft

1 ft
 ID : 1,824 inch x 12 𝑖𝑛𝑐ℎ = 0,0687 ft

Temperature pada fluida panas( inner pipe )


T1+T2 ( 50 + 45,7)°C
Tav = = = 47,85° C = 118,13 ° F
2 12 𝑖𝑛𝑐ℎ

Ρ air pada suhu 47,83° C = 989 kg / m3


2 𝑑𝑚 60 𝑚𝑖𝑛 1𝑚
WH = 𝑥 𝑥 989 𝑘𝑔/𝑚𝑖𝑛3 𝑥
𝑚𝑖𝑛 1 ℎ𝑟 103 𝑑𝑚3

= 118,68 kg / hr
Temperature pada fluida dingin( inner pipe )
T1+T2 ( 17,7+32,2) ° C
Tav = = = 24,95° C = 79,61° F
2 2

Ρ air padasuhu24,95 ° C = 997,1 kg / m3


1𝑑𝑚3 60 𝑚𝑖𝑛 1𝑚
Wc = 𝑥 𝑥 997,1𝑘𝑔/𝑚𝑖𝑛3 𝑥
𝑚𝑖𝑛 1 ℎ𝑟 103 𝑑𝑚3

= 59,826 kg / hr
a. Heat Balance
QH = QC +QLOSS

 QH = WH. Cp. ∆T
= 118,68 Kg/hr x 4,180 KJ/Kg.K (318,7 - 323)K
= -2.13,1543 KJ/hr
 QC = WC. Cp. ∆T
= 59,826Kg/hr x 4,181 KJ/Kg.K (305,2-290,7)K
= 3.626,05KJ/hr
 Q LOSS = QH – QC
= -2.133,1543 KJ/hr - 3.626,05KJ/hr
= -5.759,2043 KJ/hr

b. LMTD (logarithmic Mean Temperature Difference)


(𝑇1−𝑡1)−(𝑇2−𝑡2)
LMTD = 𝑇1−𝑡1
ln ( )
𝑇2−𝑡2
(50−17,7)−(45,7−32,2)
= 50−17,7
ln( )
45,7−32,2
18,8
= 0,87
= 21,5522

I n n e r p i p e A n n u l u s

c. Flow Area (Ap) Flow Area (Aa)


1 2 D1 = 0,0518ft
Ap = 4 𝜋𝐷
1 D2 = 0,0687 ft
= 4 (3,14)(0,0518 𝑓𝑡)2 1
2
 Aa = 4 𝜋(𝐷22– D12)
= 0,0021 ft 1
= 4 (3,14)(0,0687 ft 2 − 0,0518 𝑓𝑡2)
= 0,0016 ft2
(𝐷22 – 𝐷12 )
 Da = 𝐷1
(0,0687 ft2 −0,0518 𝑓𝑡2)
= 0,0518 ft
= 0,0393 ft

d. Mass velocity (Gp) Mass velocity (Ga)


𝑊ℎ 118,68 𝐾𝑔/ℎ𝑟 𝑊𝑐 59,826 𝐾𝑔/ℎ𝑟
 Gp = =  Ga = =
𝐴𝑝 0,0021 𝑓𝑡 𝐴𝑎 0,0016 𝑓𝑡
= 56.514,28 Kg/ft2.hr = 35.516,25 Kg/ft2.hr
= 124.592,66 lb/ft2.hr = 78.299,92 lb/ft2.hr

e. Re p Re a
T = 118,130F T = 76,910F
𝑙𝑏 𝑙𝑏
2,42 .ℎ𝑟 2,42 .ℎ𝑟
𝑓𝑡 𝑓𝑡
µp = 0,6 cp x µa = 0,9cp x
1 𝑐𝑝 1 𝑐𝑝
= 1,452 lb/ft.hr = 2,178 lb/ft.hr

𝐷𝑝.𝐺𝑝 𝐷𝑎.𝐺𝑎
Rep = Rea =
µ𝑝 µ𝑎
0,0518 ft x 124.592,66 lb/f𝑡2.hr 0,0393 ft x 78.299,92lb/f𝑡2.hr
= 𝑙𝑏 = 𝑙𝑏
1,452 .ℎ𝑟 2,178 .ℎ𝑟
𝑓𝑡 𝑓𝑡

= 4.444,834 lb/ft.hr = 1.338,489 lb/ft.hr

f. JH → Re p =4.444,834 lb/ft.h r JH → Re a = 1.338,489 lb/ft.h r


Dari bukuKern fig.28 didapatnilai JH = 35 Dari bukuKern fig.28 didapatnilai JH
= 1 8

g. MenghitungbilanganPrandlt MenghitungbilanganPrandlt
T = 118,130F T = 76,910F
Interpolasinilai k Interpolasinilai k
T ( 0 F ) k (Btu/ft 2 .hr)( 0 F/ft) T ( 0 F ) k (Btu/ft 2 .hr)( 0 F/ft)

8 6 0 , 3 5 6 3 2 0 , 3 3
1 1 8 , 1 3 ? 7 6 , 9 1 ?
1 4 0 0 , 3 8 1 8 6 0 , 3 5 6
119,13 − 86 76,91−32
k = 0,356 +( ) (0,356 – 0,33) k = 0,33 +( ) (0,356 – 0,33)
140 − 86 86−32
= 0,33 + 0,0413 = 0,33 + 0,02258
= 0,3709 Btu/ft2.hr(0F/ft) = 0,3516 Btu/ft2.hr(0F/ft)

0,2389 𝐵𝑡𝑢/𝑙𝑏 0,2389 𝐵𝑡𝑢/𝑙𝑏


C = 4,180 KJ/Kg.K x C = 4,181 KJ/Kg.K x
1 𝐾𝐽/𝐾𝑔.𝐾 1 𝐾𝐽/𝐾𝑔.𝐾
= 0,9986 Btu/lb = 0,9986 Btu/lb
1 1
1 𝐵𝑡𝑢 𝑙𝑏 3 1 𝐵𝑡𝑢 𝑙𝑏 3
𝐶. µ 0,9986 . 1,452 . ℎ𝑟 𝐶. µ 0,9986 . 2,299 . ℎ𝑟
3 𝑙𝑏 𝑓𝑡 3 𝑙𝑏 𝑓𝑡
[ ] =[ ] [ ] =[ ]
𝑘 Btu F 𝑘 Btu F
0,3173 . hr ( ) 0,3516 . hr ( )
ft2 ft ft2 ft
= 1,57475 = 1,8690

h. Menghitung hi Menghitung ho
1 1
𝐽𝐻.𝑘 𝐶.𝜇 3 𝜇 0,14 𝐽𝐻.𝑘 𝐶.𝜇 3 𝜇 0,14
hi = ( ) ho = ( 𝑘 ) 𝜇𝑤
𝐷𝑝 𝑘 𝜇𝑤 𝐷𝑎
35 . 0,3709 18 . 0,3516
= (1,5754)(1)0,14 = (1,8690)(1)0,14
0,0518 0,0393
= 394,7015 Btu/Kg.ft = 300,9803 Btu/Kg.ft

i. Menghitunghio
𝐼𝐷
hio = hi . 𝑂𝐷
0,0518 𝑓𝑡
= 394,7015 Btu/Kg.ftx 0,07 𝑓𝑡
= 292,0791Btu/Kg.ft

j. Clean Overall Coefficient (Vc)


ℎ𝑖𝑜 . ℎ𝑜
Vc = ℎ𝑖𝑜+ℎ𝑜
292,0791 𝑥 300,9803
= 292,0791+300,9803
= 148,23145 Btu/kg.ft

k. Design overall coefficient (𝑉𝐷 )


1 1
= V + RD
VD c
1 1
= 148,23145 + 0,001
VD
1
= 0,00775
VD
VD = 129,03226kg.ft/Btu

l. Pressure Drop (∆PP )


Rep =4444,834
0,264
f = 0,0035 + 𝑅𝑒𝑝0,42

0,264
= 0,0035 + (4444,834)0,42

=0,01125

ρair pada 47,85°C = 989kg/m3


= 61,74125 lb/ft3

4F.Gp2 .L
∆Fp = 2g.ρ2 .D
p
4(0,01125).(124592,66)2 .(4,51)
= 2(4,18 x 108 ).(61,74125)2 .(0,0518)
= 0,0191

∆Fp +ρ
∆Pp =144
0,0191+61,74125
= 144
=0,42889

Pressure Drop (∆Pa )


De’ = D2-D1
= 0,0687 ft – 0,0518 ft
= 0,0169
𝐷𝑒 ′ 𝑋 𝐺𝑎
Rea = 𝜇
(0,0169 )(78299,92)
= 2,299
= 575,5844

0,264
F = 0,0035 + 𝑅𝑒𝑎′0,42
0,264
=0,0035 + (575,5844)0,42

= 0,0218

ρair pada 24,95°C = 997,1 kg/m3


= 62,2469 lb/ft3
4F.Gp2 .L
∆Fa = 2g.ρ2 .Da
4(0,0218).(78299,92)2 .(4,51)
= 2(4,18 x 108 ).(62,2469)2 .(0,0393)
= 0,0189

Ga 78299,92
V = 3600.ρ = 3600.(62,2469) = 0,3494

V2 0,34942
Ft = = = 0,0019
2g 2.(32,2)

∆Fa +Ft
∆Pa = .ρ
144
0,0189+0,0019
= (62,2469)
144
= 0,00899
6.2. Aliran Co-Current Untuk Laju Fluida Panas (3 L/min) dan Fluida Dingin (1 L/min)
3,28
Diketahui L = 1,37 m x 1 𝑚 = 4,51 feet

HE berbentuk silinder ( ½ , ¾ )
 annulus = ¾ mch, sch = 40
1 ft
 OD : 1,05 inch x 12 𝑖𝑛𝑐ℎ = 0,0875ft

1 ft
 ID : 1,824 inch x 12 𝑖𝑛𝑐ℎ = 0,0687 ft

 Inner pipe = ½ inch, sch


1 ft
 OD : 0,84 inch x = 0,07ft
12 𝑖𝑛𝑐ℎ

1 ft
 ID : 1,824 inch x 12 𝑖𝑛𝑐ℎ = 0,0518 ft

Temperature pada fluida panas( inner pipe )


T1+T2 ( 49,1 + 46,2)°C
Tav = = = 47,65 C = 117,77 ° F
2 12 𝑖𝑛𝑐ℎ

Ρ air padasuhu 47,65° C = 989 kg / m3


3 𝑑𝑚 60 𝑚𝑖𝑛 1𝑚
WH = 𝑥 𝑥 989 𝑘𝑔/𝑚𝑖𝑛3 𝑥
𝑚𝑖𝑛 1 ℎ𝑟 103 𝑑𝑚3

= 178,02 kg / hr
Temperature pada fluida dingin( inner pipe )
T1+T2 ( 18,9+33,2) ° C
Tav = = = 26,05° C = 78,89° F
2 2

Ρ air pada suhu 24,95 ° C = 997 kg / m3


1𝑑𝑚3 60 𝑚𝑖𝑛 1𝑚
Wc = 𝑥 𝑥 997,1𝑘𝑔/𝑚𝑖𝑛3 𝑥
𝑚𝑖𝑛 1 ℎ𝑟 103 𝑑𝑚3

= 59,82 kg / hr

a. Heat Balance
QH = QC +QLOSS

 QH = WH. Cp. ∆T
= 178,02 Kg/hr x 4,180 KJ/Kg.K (318,2-321,1)K
= -2.157,9584 KJ/hr
 QC = WC. Cp. ∆T
= 59,82Kg/hr x 4,181 KJ/Kg.K (305,2-290,9)K
= 3.576,5361 KJ/hr
 Q LOSS = QH – QC
= -2.157,9584 KJ/hr - 3576,5361 KJ/hr
= -5.734,4945 KJ/hr

b. LMTD (logarithmic Mean Temperature Difference)


(𝑇1−𝑡1)−(𝑇2−𝑡2)
LMTD = 𝑇1−𝑡1
ln ( )
𝑇2−𝑡2
(49,1−18,9)−(46,2−33,2)
= 49,1−18,9
ln( )
46,2−33,2
17,2
= 0,84
= 20,477

I n n e r p i p e A n n u l u s

c. Flow Area (Ap) Flow Area (Aa)


1 D1 = 0,0518ft
Ap = 4 𝜋𝐷 2
1 D2 = 0,0687 ft
= 4 (3,14)(0,0518 𝑓𝑡)2 1
2
 Aa = 4 𝜋(𝐷22– D12)
= 0,0021 ft 1
= 4 (3,14)(0,0687 ft 2 − 0,0518 𝑓𝑡2)
= 0,0016 ft2
(𝐷22 – 𝐷12 )
 Da = 𝐷1
(0,0687 ft2 −0,0518 𝑓𝑡2)
= 0,0518 ft
= 0,0393 ft

d. Mass velocity (Gp) Mass velocity (Ga)


𝑊𝑝 178,02 𝐾𝑔/ℎ𝑟 𝑊𝑐 59,82 𝐾𝑔/ℎ𝑟
 Gp = =  Ga = =
𝐴𝑝 0,0021 𝑓𝑡 𝐴𝑎 0,0016 𝑓𝑡
= 84.771,43 Kg/ft2.hr = 37.387,5 Kg/ft2.hr
= 186.887,095 lb/ft2.hr = 82.424,48 lb/ft2.hr

e. Re p Re a
T = 117,17 0F T = 78,89 0F
𝑙𝑏 𝑙𝑏
2,42 .ℎ𝑟 2,42 .ℎ𝑟
𝑓𝑡 𝑓𝑡
µp = 0,6 cp x µa = 0,9cp x
1 𝑐𝑝 1 𝑐𝑝
= 1,452 lb/ft.hr = 2,178 lb/ft.hr

𝐷𝑝.𝐺𝑝 𝐷𝑎.𝐺𝑎
Rep = Rea =
µ𝑝 µ𝑎
0,0518 ft x 186.887,095 lb/f𝑡2.hr 0,0393 ft x 82.424,48 lb/f𝑡2.hr
= 𝑙𝑏 = 𝑙𝑏
1,452 .ℎ𝑟 2,178 .ℎ𝑟
𝑓𝑡 𝑓𝑡

= 6.667,18 lb/ft.hr = 1.487,27 lb/ft.hr

f. JH → Re p = 6.667,18 JH → Re a = 1.487,27 lb/ft.hr


Dari buku Kern fig.28 didapatnilai JH =40 Dari bukuKern fig.28 didapatnilai JH =20

g. MenghitungbilanganPrandlt MenghitungbilanganPrandlt
T = 117,770F T = 78,890F
Interpolasinilai k Interpolasinilai k
T ( 0 F ) k (Btu/ft 2 .hr)( 0 F/ft) T ( 0 F ) k (Btu/ft 2 .hr)( 0 F/ft)

3 2 0 , 3 3 3 2 0 , 3 3
8 6 0 , 3 5 6 7 8 , 8 9 ?
1 1 7 , 7 7 ? 8 6 0 , 3 5 6
117,77−32 78,89−32
k = 0,33 +( ) (0,356 – 0,33) k = 0,33 +( ) (0,356 – 0,33)
86−32 86−32
= 0,33 + 0,0413 = 0,33 + 0,02258
= 0,3713 Btu/ft2.hr(0F/ft) = 0,35258 Btu/ft2.hr(0F/ft)

0,2389 𝐵𝑡𝑢/𝑙𝑏 0,2389 𝐵𝑡𝑢/𝑙𝑏


C = 4,180 KJ/Kg.K x C = 4,181 KJ/Kg.K x
1 𝐾𝐽/𝐾𝑔.𝐾 1 𝐾𝐽/𝐾𝑔.𝐾
= 0,9986 Btu/lb = 0,9988 Btu/lb
1 1
1 𝐵𝑡𝑢 𝑙𝑏 3 1 𝐵𝑡𝑢 𝑙𝑏 3
𝐶. µ 0,9986 . 1,452 . ℎ𝑟 𝐶. µ 0,9988 . 2,178 . ℎ𝑟
3 𝑙𝑏 𝑓𝑡 3 𝑙𝑏 𝑓𝑡
[ ] =[ ] [ ] =[ ]
𝑘 Btu F 𝑘 Btu F
0,3173 . hr ( ) 0,35258 . hr ( )
ft2 ft ft2 ft
= 1,57475 = 1,8341

h. Menghitung hi Menghitung ho
1 1
𝐽𝐻.𝑘 𝐶.𝜇 3 𝜇 0,14 𝐽𝐻.𝑘 𝐶.𝜇 3 𝜇 0,14
hi = ( ) ho = ( 𝑘 ) 𝜇𝑤
𝐷𝑝 𝑘 𝜇𝑤 𝐷𝑎
40 . 0,3713 20 . 0,35258
= (1,5748)(1)0,14 = (1,8341)(1)0,14
0,0518 0,0393
= 451,509 Btu/Kg.ft = 329,094Btu/Kg.ft

i. Menghitunghio
𝐼𝐷
hio = hi . 𝑂𝐷
0,0518 𝑓𝑡
= 451,509 x 0,07 𝑓𝑡
= 334,1167Btu/Kg.ft

j. Clean Overall Coefficient (Vc)


ℎ𝑖𝑜 . ℎ𝑜
Vc = ℎ𝑖𝑜+ℎ𝑜
334,1167 𝑥 329,094
= 334,1167+329,094
= 165,793 Btu/kg.ft
k. Design overall coefficient (𝑉𝐷 )
1 1
= V + RD
VD c
1 1
= 165,793 + 0,001
VD
1
= 0,00703
VD
1
= 142,24751kg.ft/Btu
VD
l. Pressure Drop (∆PP )
Rep =6667,18
0,264
f = 0,0035 + 𝑅𝑒𝑝0,42
0,264
= 0,0035 + (6667,18)0,42
= 0,01004

ρair pada 47,65°C = 989kg/m3


= 61,7432 lb/ft3

4F.Gp2 .L
∆Fp = 2g.ρ2 .D
p
4(0,01004).(186887,095)2 .(4,51)
= 2(4,18 x 108 ).(61,7432)2 .(0,0518)
= 0,03832

∆Fp +ρ
∆Pp = 144
0,03832+61,7432
= 144
=0,42904

Pressure Drop (∆Pa )


Rea = 5334,5998
0,264
F = 0,0035 + 𝑅𝑒𝑎0,42
0,264
=0,0035 + (5334,5998)0,42
= 0,01068

ρair pada 26,05°C = 997kg/m3


= 62,2427 lb/ft3
4F.Gp2 .L
∆Fa = 2g.ρ2 .Da
4(0,01068).(82424,48)2 .(4,51)
= 2(4,18 x 108 ).(62,2427)2 .(0,0393)
= 0,010284

Ga 82424,48
V = 3600.ρ = 3600.(62,2427) = 0,3678

V2 0,3678
Ft = 2g = 2.(32,2) = 0,0021011

∆Fa +Ft
∆Pa = 144

0,010284+0,0021011
= (62,2421)
144
= 0,00535335

6.3. Aliran Co-Current Untuk Laju Fluida Panas (4 L/min) dan Fluida Dingin (1 L/min)
3,28ft
L = 1.37m x = 4,51ft
1m

HE berbentuk silinder (½ inchi, ¾ inchi)

 Annulus pipe ¾ inchi, sch = 40


1ft
OD = 1,05 inchi x 12 inchi = 0,0875 ft
1ft
ID = 0,824 inchi x 12 inchi = 0,0687 ft

 Inner½ inchi, sch = 40


1ft
OD = 0,84 inchi x 12 inchi = 0,07 ft
1ft
ID = 0,622 inchi x 12 inchi = 0,0518 ft

 Temperatur pada fluida panas (inner pipe)


T1 +T2
Tav = 2
(48,3+46,1)°C
= 2
= 47,2℃ = 116,96℉ = 320,2K

 Ρ air pada temperatur 47,2℃ = 989kg/m3


4dm3 60 min 1 m3
WH = x x 989kg/m3 x 10 dm3
2 1hr
= 237,36 kg/hr

 Temperatur pada fluida dingin


t1 +t2
t av = 2
(19,4 + 33,7)°C
= 2
= 26,55℃ = 79,79℉ = 299,55 K

 Ρ air pada temperatur 26,55℃ = 996,7 kg/m3


1 dm3 60 min 1 m3
Wc = x x 996,7 kg/m3 x 10 dm3
2 1hr
= 59,802 kg/hr
a. Heat Balance
QH = QC +QLOSS

 QH = WH. Cp. ∆T
= 273,36 Kg/hr x 4,180 KJ/Kg.K (319,1-321,3)K
= -2.182,763 KJ/hr
 QC = WC. Cp. ∆T
= 59,802 Kg/hr x 4,179 KJ/Kg.K (306,7-292,4)K
= 3.573,749KJ/hr
 Q LOSS = QH – QC
= -2.182,763 KJ/hr - 3573,749 KJ/hr
= -5.756,512 KJ/hr

b. LMTD (logarithmic Mean Temperature Difference)


(𝑇1−𝑡1)−(𝑇2−𝑡2)
LMTD = 𝑇1−𝑡1
ln ( )
𝑇2−𝑡2
(48,3−19,4)−(46,1−33,7)
= 48,3−19,4
ln( )
46,1−33,7

= 19,5035

I n n e r p i p e A n n u l u s

c. Flow Area (Ap) Flow Area (Aa)


1 2 D1 = 0,0518ft
Ap = 4 𝜋𝐷
1 D2 = 0,0687 ft
= 4 (3,14)(0,0518 𝑓𝑡)2 1
2
 Aa = 4 𝜋(𝐷22– D12)
= 0,0021 ft 1
= 4 (3,14)(0,0687 ft 2 − 0,0518 𝑓𝑡2)
= 0,0016 ft2
(𝐷22 – 𝐷12 )
 De= 𝐷1
(0,0687 ft2 −0,0518 𝑓𝑡2)
= 0,0518 ft
= 0,0393 ft

d. Mass velocity (Gp) Mass velocity (Ga)


𝑊𝑝 237,36 𝐾𝑔/ℎ𝑟 𝑊𝑐 59,802 𝐾𝑔/ℎ𝑟
 Gp = =  Ga = =
𝐴𝑝 0,0021 𝑓𝑡 𝐴𝑎 0,0016 𝑓𝑡
= 113028,5714 Kg/ft2.hr = 37376,25 Kg/ft2.hr
= 249185,3452 lb/ft2.hr = 82400,5262 lb/ft2.hr

e. Re p Re a
T = 116,960F T = 79,790F
𝑙𝑏 𝑙𝑏
2,42 .ℎ𝑟 2,42 .ℎ𝑟
𝑓𝑡 𝑓𝑡
µp = 0,6 cp x µa = 0,9cp x
1 𝑐𝑝 1 𝑐𝑝
= 1,452 lb/ft.hr = 2,178 lb/ft.hr

𝐷𝑝.𝐺𝑝 𝐷𝑎.𝐺𝑎
Rep = Rea =
µ𝑝 µ𝑎
0,0518 ft x 249185,3452 lb/f𝑡2.hr 0,0393 ft x 82400,5662 lb/f𝑡2.hr
= 𝑙𝑏 = 𝑙𝑏
1,452 .ℎ𝑟 2,178 .ℎ𝑟
𝑓𝑡 𝑓𝑡

= 8889,67 lb/ft.hr = 1.486,84 lb/ft.hr

f. JH → Re p = 8889,67 lb/ft.hr JH → Re a = 1.486,84 lb/ft.hr


Dari bukuKern fig.28 didapatnilai JH = 55 Dari bukuKern fig.28 didapatnilai JH = 20

g. MenghitungbilanganPrandlt MenghitungbilanganPrandlt
T = 116,960F T = 79,790F
Interpolasinilai k Interpolasinilai k
T ( 0 F ) k (Btu/ft 2 .hr)( 0 F/ft) T ( 0 F ) k (Btu/ft 2 .hr)( 0 F/ft)

8 6 0 , 3 5 6 3 2 0 , 3 3
1 1 6 , 9 6 ? 7 8 , 8 9 ?
1 4 0 0 , 3 8 1 8 6 0 , 3 5 6
117,77−32 78,89−32
k = 0,33 +( ) (0,356 – 0,33) k = 0,33 +( ) (0,356 – 0,33)
86−32 86−32
= 0,33 + 0,0413 = 0,33 + 0,02258
= 0,3703 Btu/ft2.hr(0F/ft) = 0,3530 Btu/ft2.hr(0F/ft)

0,2389 𝐵𝑡𝑢/𝑙𝑏 0,2389 𝐵𝑡𝑢/𝑙𝑏


C = 4,180 KJ/Kg.K x C = 4,179 KJ/Kg.K x
1 𝐾𝐽/𝐾𝑔.𝐾 1 𝐾𝐽/𝐾𝑔.𝐾
= 0,9986 Btu/lb = 0,9984 Btu/lb
1 1
1 𝐵𝑡𝑢 𝑙𝑏 3 1 𝐵𝑡𝑢 𝑙𝑏 3
𝐶. µ 0,9986 . 1,452 . ℎ𝑟 𝐶. µ 0,9984 . 2,178 . ℎ𝑟
3 𝑙𝑏 𝑓𝑡 3 𝑙𝑏 𝑓𝑡
[ ] =[ ] [ ] =[ ]
𝑘 Btu F 𝑘 Btu F
0,3703 . hr ( ) 0,3530 . hr ( )
ft2 ft ft2 ft
= 1,5761 = 1,8331

h. Menghitung hi Menghitung ho
1 1
𝐽𝐻.𝑘 𝐶.𝜇 3 𝜇 0,14 𝐽𝐻.𝑘 𝐶.𝜇 3 𝜇 0,14
hi = ( ) ho = ( 𝑘 ) 𝜇𝑤
𝐷𝑝 𝑘 𝜇𝑤 𝐷𝑎
55 .0,3703 20 . 0,3530
= (1,5761)(1)0,14 = (1,8331)(1)0,14
0,0518 0,0393
= 619,68 Btu/Kg.ft = 329,30 Btu/Kg.ft

i. Menghitunghio
𝐼𝐷
hio = hi . 𝑂𝐷
0,0518 𝑓𝑡
= 619,68x 0,07 𝑓𝑡
= 458,5632Btu/Kg.ft

j. Clean Overall Coefficient (Vc)


ℎ𝑖𝑜 . ℎ𝑜
Vc = ℎ𝑖𝑜+ℎ𝑜
458,5632 𝑥 329,30
= 458,5632 +329,30
= 191,663809 Btu/kg.ft

k. Design Overall Coeficient


1 1
= + 𝑅𝑝
𝑉𝐷 𝑉𝐶
1 1
= + 0,001
𝑉𝐷 191,663809
VD = 160,838936 (Btu/hr ft2) (of/ft)
I n n e r P i p e A n n u l u s
l . Pressure Drop (ΔPp) Pressure Drop (ΔPa)
Re P = 8889,67 De = D2 – D1
= (0,0687 – 0,0518) ft
0,264 = 0,0169 ft
F= 0,0035 + (𝑅𝑒𝑃) 2
0,264
= 0,0035 + (8889,67) 2 𝐷𝑒 .𝐺𝑎
Re a = 𝜇
= 0,00929
0,0169 𝑓𝑡 .82400,5262 𝑙𝑏/ℎ𝑟𝑓𝑡2
= 2,178 𝑙𝑏/𝑓𝑡ℎ𝑟
o 3
𝜌 air pada suhu 47,2 C adalah 989 kg/m = 639,3796
3
= 61,7136 lb/ft
0,264
F= 0,0035 + (𝑅𝑒𝑃) 2
4𝐹 .𝐺𝑝2 .𝐿
ΔFp = 0,264
2𝑔 . 𝐷 .𝜌2 = 0,0035 + (639,3796) 2
4(0,00929).(249185,34522 .(4,51)
= 2(4,18 𝑥 108 ).(0,00518).(61,7136)2 = 0,01981

= 0,4290
𝜌 air pada suhu 26,55 oC adalah 996,7 kg/m3
ΔFp+ ρ = 62,194 lb/ft3
ΔPp =
144
0,06309+ 61,7136
= 4𝐹 .𝐺𝑎2 .𝐿
144
ΔFa = 2𝑔 . 𝐷 .𝜌2
= 0,4290
4(0,01981).(82400,52)2 .(4,51)
= 2(4,18 𝑥 108 ).(0,0393).(62,194)2

= 0,01909
𝐺𝑎
𝑉=
3600 . 𝜌

82400,52
=
3600 . 62,194
= 0,3680

𝑉2
𝐹𝑡 =
2𝑔
0,36802
𝐹𝑡 = = 0,0021
2(32,2)
ΔFa+ Ft
ΔPa = .𝜌
144
0,01909+ 0,0021
= .62,194
144

= 0,00913

VII. ANALISIS PERCOBAAN


Pada praktikum minggu kedua ini, kami menggunakan Heat Exchanger dengan aliran
searah (Co – Current). Heat exchanger adalah alat yang memungkinkan perpindahan panas
dan bisa berfungsi sebagai pemanas maupun pendingin. Biasanya, medium pemanas dipakai
uap lewat panas dan air biasa sebagai pendingin. Adapun prinsip kerja HE yaitu
memindahkan panas dari 2 fluida pada temperature berbeda dimana transfer panas dapat
dilakukan secara langsung maupun tak langsung.
Co – Current flow adalah aliran searah, dimana kedua fluida masuk pada ruang
penukar panas yang sama dengan kedua fluida yang mengalir searah menuju ujung panas
yang lain. Pada aliran searah, selisih antara temperatur fluida panas dan digin akan menurun
seiring dengan meningkatnya laju alir. Hal ini dapat terjadi jika kita anggap ada sebuah
molekul yang mengalir dalam pipa, maka molekul-molekul fluida panas dan dingin akan
selalu bersama-sama pada akhirnya panas akan berpindah diantaranya.
Pada praktikum ini dibuat 3 variasi laju alir yaitu 2 l/min ,3 l/min ,4 l/min sedangkan
fluida dingin dibuat tetap 1 l/min. Berdasarkan praktikum yang telah dilaksanakan dapat
diketahui bahwa, laju alir fluida panas 2 l/min akan lebih lama kontak dengan fluida dingin.
Hal ini dikarenakan apabila laju alir kecil akan membuat aliran air kecil sehingga proses
pemanasan dinding pipa kontak dengan fluida dingin pada annulus akan menyebabkan proses
perpindahan panasnya merata dan lebih lama. Begitu juga sebaliknnya untuk laju alir yang
paling besar yaitu 4 l/min akan lebih cepat kontak dengan fluida dingin karena aliran air
besar.
Adapun faktor-faktor yang harus diperhatikan dalam mengoperasikan alat penukar panas
adalah proses perpindahan panas, perbedaan suhu, luas permukaan, dan konduktivitas.
VIII. KESIMPULAN
Pada praktikum yang telah dilakukan dapat disimpulkan bahwa:
1. Proses perpindahan panas pada heat exchanger tipe double pipe berlangsung secara
indirect contact (kontak tidak langsung)
2. Semakin besar laju, maka kalor yang diserap oleh dinding pipa semakin banyak,
sehingga proses perpindahan panasnyaakan semakin banyak
3. Faktor yang mempengaruhi perpindahan panas yaitu:
o Perbedaan suhu
o Luas permukaan
o Konduktivitas media penghantar
4. Harga LMTD untuk aliran counter current lebih besar dibandingkan aliran co-current
5. Faktor yang mempengaruhi nilai LMTD
o Kenaikan laju fluida
o Perpindahan panas
o Perbedaan suhu
6. Efisiensi pada aliran counter current lebih besar dibandingkan dengan aliran co-
current

IX. DAFTAR PUSTAKA


Kasie Laboratorium Satuan Operasi 2. 2019. Penuntun Praktikum Satuan Operasi 2.
Palembang: Politeknik Negeri Sriwijaya.
http://wiwinpertiwiproduction.blogspot.com/2012/05/macam-macam-heat-
exchanger.html?m=1 ((Diakses pada 3 Maret 2019 pukul 17.09)
http://artikel-teknologi.com/macam-macam-heat-exchanger-alat-penukar-panas-bagian-3/
(Diakses pada 3 Maret 2019 pukul 20.17)
http://artikel-teknologi.com/macam-macam-heat-exchanger-alat-penukar-panas-bagian-1/
(Diakses pada 3 Maret 2019 pukul 23.26)

You might also like