You are on page 1of 13

Nama Anggota Kelompok/NIM:

1. Aaron Julian Sali/05201001


2. Eka Kurniati Kombong
Datu/05201026
3. Muhammad Ridho
Hafizi/05201055
4. Muhammad Rofiqi Abiyyu
Sholih/05201056
Progress report ke* – 1 / 2 / 3

*lingkari

Deskripsi pengerjaan:

Pemilihan dimensi pipa IPS (3) in


Pemilihan suhu fluida pemanas (saturated steam ) yang digunakan pada proses
Cold fluids :
T1 = 15°C
T2 = 28°C
Hot fluids :
T1 = 80°C
T2 = 30°C
Perhitungan ΔTLMTD dan pemilihan arah aliran
( 30−28 )−(80−15)
LMTD= =18,1 °C ( Paralel Flow)
( )
ln ⁡
2
65
( 30−15 )−(80−28)
LMTD= =30 ° C=86 ° F (Counter Flow )
( )
ln ⁡
15
52
Aliran yang dinginkan adalah counter flow

Benzene = 60.000 kj/hour = 132.277,36 lb/hour


T1 = 80°C = 176°F
T2 = 30°C = 86°F
Cooling water
T1 = 15°C = 59°F
T2 = 28°C = 82.4°F

Fouling factor = 0,001


Mnggunakan 20-ft hairpins

DPHE Model 1
(1) Heat Balance
Q=ṀC ∆ T =ṁc ∆ t
Hot Benzene
176+86
t avg= =131° F
2

C=0,44 Btu /(lb ° F ) at 131° F

Q=(132.277,36)(0,44)(176−86)=5.238 .183 Btu /hr

Cold Cooling Water


82.4+59
t avg= =70,7° F
2
C=1 Btu /(lb ° F) at 70,7 ° F

5.238.183
Ṁ= =402.937,15lb /hr
(1)(28−15)

(2) LMTD
( 30−15 )−(80−28)
LMTD= =30 ° C=86 ° F
ln ⁡ ( )
15
52
Hot Fluid (Benzene) - Cold Fluid (Cooling water) -
Annulus (ɑ) Inner pipe (p)

(4’) Flow Area, ɑ ɑ (4’) Flow Area, ɑ p


D 2=6,065∈¿ D=3,068∈¿

¿ 0,5054 ft ¿ 0,2557 ft

D1=3,50∈¿

¿ 0,292 ft

π D2 π
ɑ ɑ= ( D22−D 21) ɑ p=
4 4
2
π (0,2557) π
¿ ¿ ¿
4 4

¿ 0,13358 ft 2 ¿ 0,0513 ft 2

Equivalent Diameter, De
D22−D21
De=
D1

2 2
(0,5054) −(0,292)
¿
0,292
¿ 0,5827 ft

(5’) Mass Velocity, Gɑ (5) Mass Velocity,G p

Ṁ 132.277,36 ṁ 402.937,15
G ɑ= = G p= =
ɑɑ 0,13358 ɑp 0,0513

2 2
¿ 453 . 004 , 65 lb /(hr . ft ) ¿ 7 . 854 . 525 ,34 lb / (hr . ft )

(6’) At 131 ° F , μ=0,4 1 cP (6) At 70,7 ° F , μ=0,94 cP

( ) ( )
2 2
2,42lb /(hr . ft ) 2,42 lb /(hr . ft )
μ=0,4 1 cP μ=0,94 cP
1 cP 1 cP

¿ 0,9922 lb /(hr . ft 2) ¿ 2 ,27 5 lb /( hr . ft 2)

(7’) Reynolds Number, ℜɑ (7) Reynolds Number, ℜp

D e Gɑ D Gp
ℜ ɑ= ℜp =
μ μ

(0,5827)(453 .004 ,65) (0,2557)(7 . 854 . 525 , 34)


¿ ¿
0,992 2,275

¿ 266.094,57 ¿ 882.814,12

(8’) Solve for h o (8) Solve for hi

2 2
k =0,086 Btu/hr . ft .° F /ft k =0 , 35 Btu /hr . ft . ° F /ft

C=0,44 Btu /(lb ° F ) at 131° F C=1 Btu /(lb° F)at 6,5 ° F

( ) ( )( ) ( ) ( )( )
0,8 0,8
ho De De Gɑ Cμ 1
μ 0,14
hi D D Gp Cμ 1
μ 0,14
=0,027 3
=0,027 3
k μ k μw k μ k μw
( ) ( ) ( ) ( Dk )
0,8
De Gɑ Cμ 1
μ 0,14
(8’) h o=0,027 3
μ k μw e

( )
0,8 1

( ) ( )
0,14 2
G μ 1
¿ 0,027 ɑ ( Cμ k )
2 3
μ μw De

( )
0,8
453 .004 ,65
¿ 0,027 ¿¿
0,4 1

≈ 597,18 Btu/hr . ft 2 .° F

( ) ( ) ( ) ( Dk )
0,8
D Gɑ cμ
1
μ
0,14
(8’) hi =0,027 3
μ k μw

( )
0,8 1

(μ ) ( )
Gp 0,14 2
¿ 0,027 ( cμ k 2 ) 3 μ 1
μ w D

( )
0,8
7 . 854 . 525 , 34
¿ 0,027 ¿¿
0 , 94

≈ 69.752,72 Btu/hr . ft 2 .° F

hi ho (597,18)(69.752,72) 2
(9) U C = = ≈592,11 Btu /hr . ft .° F
h i+ ho 597,18+69.752,72

(10) U D :

Rd =Rd ,i + Rd ,o

¿ 0,001+0,001

¿ 0,001+0,001

1 1
= + Rd
UD UC
1 1
= + 0,002
U D 592,11

U D ≈ 271,08 Btu /hr . ft 2 . ° F

Summary
Annulus/Benzene h Inner pipe/Cold Water
597,18 2
Btu/hr . ft .° F 69.752,72
U C =592,11
U D=271,08
(11) Required surface, A:
Q
Q=U D A ∆ T LM → A=
U D ∆ T LM

5.238.183 2
A= ≈ 2 24,69 ft
(271,08)(86)

2 24,69
Required lenght, L= ≈ 245,03 lin. ft
0,917

This may be satisfied by connecting seven 20-ft hairpins at a total of 280 lin. ft of heat transfer
area. The corrected U D will be:

U D=Q / A ∆T LM =5.238 .183/(280× 0,917 ×86)

2
¿ 237,222 Btu /hr . ft . ° F

The corrected dirt factor will be:

Rd =1/ U D−1/U C =1/ 237,222−1/592,11=0,00 2526 59 hr . ft 2 . ° F / Btu

Pressure Drop

(1’) D ' e for pressure drop differs from (1) ℜp =882.814,12 from (7) above
D ' e for heat transfer

D ' e =D2−D 1

¿ 0,5054−0,292

¿ 0,2334 ft

D' e Gɑ
ℜ ɑ=
μ
(0,2334)(453 .004 , 65)
¿
0,4 1

¿ 257.881,18

(2’) Compute ∆ F ɑ and ∆ F i (2) Compute ∆ F p

0,264 0,264
f =0,0035+ 0,42
f =0,0035+ 0,42
ℜ' ɑ ℜ' p

0,264 0,264
¿ 0,0035+ 0,42
¿ 0,0035+ 0,42
(257.881,18) (882.814,12)
≈ 0,00 490866 ≈ 0,004 340115
S=0,38 S=0,3 6
lb lb
ρ=(62,5)(0,38)=24,75 3 ρ=(62,5)(0,31)=22,5
ft ft 3
2
4 f Gɑ L 4f G L
2
∆ F a= 2 ∆ F p= 2
2 g ρ D 'e 2g ρ D

4 (0,00490866)(453 . 004 , 65)2 (28 0)


¿ 8 2
2(4,18 ×10 )(24,75) (0,5827)
4 (0,004340115)(7 .854 .525 , 34)2 (28 0)
¿
2(4,18× 108 )(22,5)2 (0,2557)

¿ 3,78 ft of Benzene ¿ 2771,13 ft of Ammonia

Gɑ 453 . 004 , 65
v= =
3600 ρ (3600)(24,75)

≈ 5,08

( ) [ ]
2 2
v (5,08)
∆ F i=7 =7
2 g' 2(32,2)

≈ 2,805 ft of Benzene

(3’) Compute ∆ Pɑ (3) Compute ∆ P p

(∆ F ɑ+ ∆ Fi ) ρ ρ
∆ Pɑ= ∆ P p=∆ F p
144 144

( 3,78+ 2,805 ) 24,75 (2771,13)(2 2, 5)


¿ ¿
144 144
≈ 1 ,131796875 psi ≈ 432,9890625 psi

∆ Pɑ < 10 psi is allowable ∆P ∆ P p > 10 psi is non allowable ∆P

DPHE Model 2
(1) Heat Balance
Q=ṀC ∆ T =ṁc ∆ t
Hot Benzene
176+86
t avg= =131° F
2
ṁ = 132.277,36 lb /hr
C=0,44 Btu /(lb ° F ) at 131° F

Q=(132.277,36)(0,44)(176−86)=5.238 .183 Btu /hr

Cold Cooling Water


82.4+59
t avg= =70,7° F
2
C=1 Btu /(lb ° F) at 70,7 ° F

5.238.183
Ṁ= =402.937,15lb /hr
(1)(28−15)

(2) LMTD
( 30−15 )−(80−28)
LMTD= =30 ° C=86 ° F
ln ⁡( )
15
52
Cold Fluid (Cooling water) - Hot Fluid (Benzene) -
Annulus (ɑ) Inner pipe (p)
(4’) Flow Area, ɑ ɑ (4’) Flow Area, ɑ p
D 2=6,065∈¿ D=3,068∈¿

¿ 0,5054 ft ¿ 0,2557 ft

D1=3,50∈¿

¿ 0,292 ft
2
π 2 2 D π
ɑ ɑ= ( D2−D 1) ɑ p=
4 4
2
π (0,2557) π
¿ ¿ ¿
4 4

¿ 0,13358 ft 2 ¿ 0,0513 ft 2

Equivalent Diameter, De

D22−D21
De=
D1

2 2
(0,5054) −(0,292)
¿
0,292
¿ 0,5827 ft

(5’) Mass Velocity, Gɑ (5) Mass Velocity,G p

Ṁ 402.937,15 ṁ 132.277,36
G ɑ= = G p= =
ɑɑ 0,13358 ɑp 0,0513

¿ 3 . 016 . 448 ,19 lb /( hr . ft 2) ¿ 2.578 .506 lb /(hr . ft 2)

(6’) At 70,7 ° F , μ=0,94 cP (6) At 131 ° F , μ=0,41 cP

( ) ( )
2 2
2,42 lb/(hr . ft ) 2,42lb /( hr . ft )
μ=0 , 94 cP μ=0 , 41 cP
1 cP 1 cP

¿ 2,275 lb/(hr . ft 2 ) ¿ 0,9922 lb /(hr . ft 2)

(7’) Reynolds Number, ℜɑ (7) Reynolds Number, ℜp

D e Gɑ D Gp
ℜ ɑ= ℜp =
μ μ
(0,5827)(3 . 016 . 448 , 19) (0,2557)(2.578 .506)
¿ ¿
2,275 0,9922

¿ 772.608,51 ¿ 664 .507,14

(8’) Solve for h o (8) Solve for hi

2 2
k =0,35 Btu /hr . ft .° F/ ft k =0,086 Btu/hr . ft .° F /ft

C=1 Btu /(lb° F)at 6,5 ° F C=0,44 Btu /(lb ° F ) at 131° F

( ) ( )( ) ( ) ( )( )
0,8 0,8
ho De De Gɑ Cμ
1
μ
0,14
hi D D Gp Cμ
1
μ
0,14
=0,027 3
=0,027 3
k μ k μw k μ k μw

( ) ( ) ( ) ( Dk )
0,8
De Gɑ Cμ
1
μ
0,14
(8’) h o=0,027 3
μ k μw e

( )
0,8 1

( ) ( )
G μ 0,14
1 2
¿ 0,027 ɑ ( Cμ k )
2 3
μ μw De

( )
0,8
3 . 016 . 448 , 19
¿ 0,027 ¿¿
0 , 94

≈ 4.709,85 Btu/hr . ft 2 .° F

( ) ( ) ( ) ( Dk )
0,8
D Gɑ cμ 1
μ 0,14
(8’) hi =0,027 3
μ k μw

( )
0,8 1

(μ ) ( )
Gp 0,14 2
¿ 0,027 ( cμ k 2 ) 3 μ 1
μ w D

( )
0,8
2.578 .506
¿ 0,027 ¿¿
0 , 41
≈ 15.876,94 Btu/hr . ft 2 .° F

hi ho (4.709,85)(15.876,94) 2
(9) U C = = ≈ 3 . 632 ,33 Btu/hr . ft .° F
h i+ ho 4.709,85+15.876,94

(10) U D :

Rd =Rd ,i + Rd ,o

¿ 0,001+0,001

¿ 0,001+0,001

1 1
= + Rd
UD UC

1 1
= +0,002
U D 3632,33

2
U D ≈ 4 39,501 Btu /hr . ft . ° F

Summary
Annulus/Cooling Water h Inner pipe/Benzene
4.709,85 2
Btu/hr . ft .° F 15.876,94
U C =3 .632,33
U D=439,501
(11) Required surface, A:
Q
Q=U D A ∆ T LM → A=
U D ∆ T LM

5.238.183 2
A= ≈ 138,59 ft
(439,501)(86)

138,59
Required lenght, L= ≈ 151,13 lin . ft
0,917

This may be satisfied by connecting four 20-ft hairpins at a total of 160 lin. ft of heat transfer
area. The corrected U D will be:

U D=Q / A ∆T LM =5.238 .183/(160× 0,917 ×86)

2
¿ 415,318 Btu/hr . ft .° F

The corrected dirt factor will be:


2
Rd =1/U D−1/U C =1/415,318−1 /3.632,33=0,00 213249 hr . ft . ° F /Btu

Pressure Drop

(1’) D ' e for pressure drop differs from (1) ℜp =664.507,14 from (7) above
D ' e for heat transfer

D ' e =D2−D 1

¿ 0,5054−0,292

¿ 0,2334 ft

D' e Gɑ
ℜ ɑ=
μ

(0,2334)(3 . 016 . 448 , 19)


¿
0 , 94

¿ 748.977,67

(2’) Compute ∆ F ɑ and ∆ F i (2) Compute ∆ F p

0,264 0,264
f =0,0035+ 0,42
f =0,0035+ vf 0,42
ℜ' ɑ ℜ' p

0,264 0,264
¿ 0,0035+ 0,42
¿ 0,0035+ 0,42
(748.977,67) (664.507,14)
≈ 0,004 440018 ≈ 0,004 44657
S=0,31 S=0,3 8
lb lb
ρ=(62,5)(0,31)=22,5 3 ρ=(62,5)(0,38)=24,75
ft ft 3
2
4 f Gɑ L 4 f G2 L
∆ F a= 2 ∆ F p= 2
2 g ρ D 'e 2g ρ D

2
4 (0,004440018)(3. 016 . 448 , 19) (160)
¿
2( 4,18× 108 )(22,5)2 (0,5827)
4 (0,00444657)(2.578.506)2 (160)
¿
2( 4,18× 108 )(2 4,75)2(0,2557)

¿ 104,84 ft of Benzene ¿ 144 , 49 ft of Ammonia


Gɑ 3 . 016 . 448 ,19
v= =
3600 ρ (3600)(2 2,5)

≈ 3 7,24

( ) [ ]
2
v2 (3 7,24)
∆ F i=4 =4
2g' 2(32,2)

≈ 86 , 1 4 ft of Benzene

(3’) Compute ∆ Pɑ (3) Compute ∆ P p

(∆ F ɑ+ ∆ Fi ) ρ ρ
∆ Pɑ = ∆ P p=∆ F p
144 144

(104,84 +86,14 ) 2 2,5 (144,49)(2 4,75)


¿ ¿
144 144

≈ 29,840625 psi ≈ 2 4,83421875 psi

∆ Pɑ > 10 psi is non allowable ∆P ∆ P p > 10 psi is non allowable ∆P

Mengetahui:

Rizka Lestari, S.T., M.Eng

You might also like