You are on page 1of 2

Zuhaltekraftberechnung

● Kaltkammer Warmkammer

Teilbezeichnung
Auslegung 1 -fach
Datum:
Sprengfläche der Teile

Sprengfläche: = Länge in cm x Breite in cm ermittelt in cm²


A = x = 0.0 cm²
Anzahl der Teile ( -fach ) 1

Sprengfläche: = p x d (²)
4
= 3.14159265 x 0 = 0.0 cm²
4
Auslegung ( -fach ) 1

Sprengfläche der Schieber

Sprengfläche: = Länge in cm x Breite in cm


A = x = 0.0 cm²
Anzahl der Schieber pro Teil 1
Tangenswert 0.46
Sprengfläche: = p x d (²)
4
= 3.14159265 x 0 = 0.0 cm²
4
Anzahl der Schieber pro Teil 1

Sprengfläche der Überlaufe ( Luftbohnen )

0% - 20% 0% = 0.0 cm²


0% - 20% 0% = 0.0 cm²

Sprengfläche des Giesslaufs mit Pressrest bzw. Verteilerkegel

20% - 60% 50% 0.0 cm²


20% - 60% 50% 0.0 cm²
Gesamtsprengfläche Asp 0.0 cm²

Sprengkraft = Sprengfläche x spez. Giessdruck


Fsp = Asp cm² x p ( 1 bar =10N / cm² )

Fsp = 0 x 800bar 10 N
1000 cm²
Fsp = 0 kN

Zuhaltekraft = Sprengkraft x Sicherheitsfaktor


Fzu = Fsp kN x Faktor

Fzu = 0 x 1.3 = 0 kN

Stand: 04/05
Locking force calculation
● cold chamber hot chamber

Part name
Layout 1 "n"
Date:
Casting area of parts

Casting area: = length (cm) x width (cm) calculated (cm²)


A = x = 259.2 259.2 cm²
Layout 1

Casting area: = p x d (²)


4
= 3.14159265 x 0 = 0.0 cm²
4
Layout 1

Casting area of slide valves

Casting area: = length (cm x width (cm) calculated (cm²)


A = 0 x 0 = 17.5 13.3 cm²
Number of slide valves per part: 2
tana 0.38
Casting area: = p x d (²)
4
= 3.14159265 x 0 = 0 0.0 cm²
4
Number of slide valves per part: 0

Casting area of overflows

0% - 20% 20% = 52 52.0 cm²


0% - 20% 0% = 0.0 cm²

Casting area of runner with biscuit or spreader

20% - 60% 50% 130 130.0 cm²


20% - 60% 50% 0.0 cm²
Total casting area Asp 454.5 cm²

Casting force = Casting area x spec. Casting pressure


Fsp = Asp cm² x p ( 1 bar =10N / cm² )

Fsp = 455 x 600bar 10 N


1000 cm²
Fsp = 2727 kN

Locking force = Casting force x safety factor


Fzu = Fsp kN x Factor

Fzu = 2727 x 1.2 = 3272.4 kN

Edition: 04/05