You are on page 1of 2

Final Data Sheet

GROUP NUMBER: 03 DATE: 31/07/19


SUBJECT & SECTION: CE140-1P/E03

EXPERIMENT NO. 4

BERNOULLI’S THEOREM DEMONSTRATION

Velocit
Volume Time to Flow Rate Distance Area of Static Dynamic Total
y
Collected Collect Into Duct Duct Head Head Head
V T Qv A h h0
V
M3 sec m3/s m m x 10-6
2 m m m
m/s
1 0.001 11.85 8.439 x 10-5 h1 0.00 490.0 0.206 0.1722 1.511 x 10-3 0.208
2 0.001 11.85 8.439 x 10-5 h2 0.0603 151.7 0.192 0.5563 1.578 x 10-2 0.572
3 0.001 11.76 8.503 x 10-5 h3 0.0687 109.4 0.176 0.7772 3.079 x 10-2 0.808
4 0.001 h4 0.0732 89.9 0.161
5 0.001 h5 0.0811 78.5 0.128
6 0.001 h6 0.1415 490.0 0.140
7 h7
8 h8
9 h9
Sample Computations

Trial 1:
𝑣 0.001 3
𝑄𝑣 = = = 8.44𝑥10−5 𝑚 ⁄𝑠
𝑡 11.85
𝑄 8.44𝑥10−5
𝑉= = = 0.1722 𝑚⁄𝑠
𝐴 490𝑥10−6
𝑣 2 (0.1722)2
𝐷. 𝐻. = = = 1.5114𝑥10−3 𝑚
2𝑔 2(9.81)
𝑇𝑜𝑡𝑎𝑙 𝐻𝑒𝑎𝑑 = 𝑆𝑡𝑎𝑡𝑖𝑐 + 𝐷𝑦𝑛𝑎𝑚𝑖𝑐

𝑇𝑜𝑡𝑎𝑙 𝐻𝑒𝑎𝑑 = 1.5114𝑥10−3 𝑚 + 0.206 𝑚


𝑇𝑜𝑡𝑎𝑙 𝐻𝑒𝑎𝑑 = 0.208 𝑚