Professional Documents
Culture Documents
Column Designation: C1
Design Parameters
f'c = 20.7 MPa Rebar diameter = 16 mm
fy = 414 MPa Longitudinal Bar = 4 pcs
Tie Diameter = 10 mm
Analysis
Check if eccentricity will be consider
e min ≥ 23 mm
e min = 15 + 0.03h
e min = 15 + 0.03(300)
e min = 24 mm
e min = 24 mm > 23 mm
Neglect the effect of eccentricity
Spacing of Ties
a. 16 (bar Diameter) = 256 mm
b. 48 (tie diameter) = 480 mm
c. Minimum Dimension of Column = 200 mm
Use 200 mm spacing of ties
Summary
4 - 16 mm Ø Main RSB with 2 - 12 mm Ø Stiffener with 10 mm Ø ties: 2@50
mm, 6@100 mm and rest 200 mm O.C.
Design of Reinforced Concrete Column
Column Designation: C2
Design Parameters
f'c = 20.7 MPa Rebar diameter = 16 mm
fy = 414 MPa Longitudinal Bar = 4 pcs
Tie Diameter = 10 mm
Analysis
Check if eccentricity will be consider
e min ≥ 23 mm
e min = 15 + 0.03h
e min = 15 + 0.03(300)
e min = 24 mm
e min = 24 mm > 23 mm
Neglect the effect of eccentricity
Spacing of Ties
a. 16 (bar Diameter) = 256 mm
b. 48 (tie diameter) = 480 mm
c. Minimum Dimension of Column = 200 mm
Use 200 mm spacing of ties
Summary
4 - 16 mm Ø Main RSB with 10 mm Ø ties: 2@50 mm, 6@100 mm and rest
200 mm O.C.
Reinforcing Bar Diameter area dia. Value of α
6 28.27 6 Interior Column 40
10 78.54 10 Edge Column 30
12 113.10 12 Corner Column 20
16 201.1 16
20 314.2 20
25 491.90 25
28 615.75 28
32 804.25 32
16 201.1 16
Tied 23 15 23
Spiral 23 30 30
23
Shear Strength of Concrete
#REF! Vc = 1/6 (1+2/β)√(f' c) bod
#REF! #REF! Vc = 1/12 (αd/bo +2)√(f' c) bod
#REF! #REF! Vc = 1/3 √(f' c) bod