You are on page 1of 8

Name : Nikolas Arta Kurnia Dekko

PIPELINE ENGINEERING NRP : '04211640000054


WALL THICKNESS CALCULATION Class :A
Lecturer :Nurhadi S., S.T., M.T.

1. DESIGN DATA
a. Pipeline Design Data

Design flow rate : 275 MMSCFD


Fluid : Natural Gas
Design Pressure : 1150 psig
Max Operating Press : 1050 psig
Min Operating Press : 300 psig
Max Design Temp : 150 F
Min Design Temp : 68 F
Design Life : 20 years

b. Pipe Specification
Material Grade : API 5L X 65
SMYS : 65000 psi
Nominal Diameter : 32 inch

c. Earth Cover
Min cover at road crossing : 2 m
Min cover at rail crossing : 2 m

d. Bends
Field Bend radius : Minimum 30 DR with a minimum 2 meter straight pipe at both ends
Shop induction bend radius : Minimum 5 DR

2. PRESSURE DESIGN WALL THICKNESS

Based on ASME B31.8 841.11 Pg. 29 , the pressure design wall thickness is calculated by the following formula:
PD
t=
2SFET
where,
t = pressure design wall thickness, inch D = Outside diameter, inch
P =design pressure, psig S = Spesified minimum yield strength, psi

F = design factor based ASME B31.8 840.22 Pg. 28


= 0.80 Location class 1, Division 1
= 0.72 Location class 1, Division 2
= 0.60 Location class 2
= 0.50 Location class 3
= 0.40 Location class 4
= 0.60 Location class 1, Division 2 for road crossing
= 0.50 Location class 2, Division 3 for road crossing
E = Longitudinal joint factor based ASME B31.8 Tabel 841.115A

Page 1 of 8
Name : Nikolas Arta Kurnia Dekko
PIPELINE ENGINEERING NRP : '04211640000054
WALL THICKNESS CALCULATION Class :A
Lecturer :Nurhadi S., S.T., M.T.
= 1.00 for API 5 L Submerged Arc Welded Pipes
T = Temperature Derating Factor based ASME B31.8 Tabel 841.116A
= 1.00 for Temperature 250 F or less

a. Pressure design wall thickness at location class 1 division 1


PD 1150 x 32
t= =
2SFET 2 x 65000 x 0,80 x 1 x 1
= 0.3538461538 inch
= 8.9876923077 mm
According to ASME B 36.10M, choosen pipe's wall thickness is 0.5 in 20 sch
b. Pressure design wall thickness at location class 1 division 2
PD 1150 x 32
t= =
2SFET 2 x 65000 x 0,72 1 x 1
= 0.3931623932 inch
= 9.9863247863 mm
According to ASME B 36.10M, choosen pipe's wall thickness is 0.5 in 20 sch
c. Pressure design wall thickness at location class 2
PD 1150 x 32
t= =
2SFET 2 x 65000 x 0,60 x 1 x 1
= 0.4717948718 inch
= 11.9835897436 mm
According to ASME B 36.10M, choosen pipe's wall thickness is 0.5 in 20 sch
d. Pressure design wall thickness at location class 3
PD 1150 x 32
t= =
2SFET 2 x 65000 x 0,50 x 1 x 1
= 0.5661538462 inch
= 14.3803076923 mm
According to ASME B 36.10M, choosen pipe's wall thickness is 0.625 in 30 sch
e. Pressure design wall thickness at location class 4
PD 1150 x 32
t= =
2SFET 2 x 65000 x 0,40 x 1 x 1
= 0.7076923077 inch
= 17.9753846154 mm
According to ASME B 36.10M, choosen pipe's wall thickness is 0.75 in 40 sch

3. SUMMARY
Location class Class 1 Div 1 Class 1 Div 2 Class 2 Class 3 Class 4
Design Factor 0.80 0.72 0.60 0.50 0.40
Pipe wall thickness (in) 0.3538461538 0.3931623932 0.4717948718 0.5661538462 0.70769230
Selected pipe wall thickness (in) 0.5 0.5 0.5 0.625 0.75
Selected pipe schedule 20 20 20 30 40

Page 2 of 8
Name : Nikolas Arta Kurnia Dekko
PIPELINE ENGINEERING NRP : '04211640000054
WALL THICKNESS CALCULATION Class :A
Lecturer :Nurhadi S., S.T., M.T.

4. ATTACHMENT

Page 3 of 8
Name : Nikolas Arta Kurnia Dekko
PIPELINE ENGINEERING NRP : '04211640000054
WALL THICKNESS CALCULATION Class :A
Lecturer :Nurhadi S., S.T., M.T.

Page 4 of 8
a Dekko
4

.T.

la:

Page 5 of 8
a Dekko
4

.T.

Class 4
0.40
0.707692308
0.75
40

Page 6 of 8
a Dekko
4

.T.

Page 7 of 8
a Dekko
4

.T.

Page 8 of 8