You are on page 1of 3

Fuel type Petcoke

Kiln coal 6.6 TPH Cooler


Guide Coal TPH 7.1 TPH Cooler Area 118.8 m2
Kiln coal NCV 7400 kcal/kg
cooler loading 46.3 tpd/m2
Burner Capacity Guide value 41 tpd/m2
Design 351 GJ/hr Clinker temperature 130 deg C

Operating
48840000 kcal/hr Fan Flux Area Fan flow
kg/m2/min m2 m3/hr
48.84 Mkcal/hr 38761 8.57 FN1 129 11.52/2 38763
38761 8.57 FN2 129 11.52/2 38763
56.7907 MW 89406 19.78 FN3 90 18.98 89410
54774 12.12 FN4 81 12.92 54777
204 GJ/hr 55819 12.35 FN5 69 15.49 55822
58604 12.96 FN6 62 18.07 58607
% utilisation 58.2 60304 13.34 FN7 56 20.66 60307
55613 12.30 FN8 50 21.17 55616

Kiln feed 353 TPH 452041.7 100 452063


Clinker 229 TPH
5501 TPD Air flow 2.27
Kiln Heat Value 213 kcal/kg CL Actual 1.80
230 kcal/kg CL Expected input flow 1.80
Guide value 230 kcal/kg CL
Guide KF value 327 TPH
Pressure
mmWg
900-1100 8.6
900-1100 8.6 74508.23
~850 19.8
~800 12.1
~700 12.3
~600 13.0
~550 13.3
~500 12.3

kg/kg clinker
Nm3/kg Clinker
Nm3/kg Clinker
11.09.19
Pressure drop Current
PH fan 850
Top cyc 765
Cyc-II 624
Cyc-III 570
Cyc-IV 475
Cyc-V 355
Cyc-VI 220
Cal
Kiln I/L 75
TAD
Hood -4

You might also like