ROTARY KILN DATA SHEET

This is only a Data sheet.


Tolerance in elevation level is +/- 1mm.

FLSMIDTH M&R NATAL

Ref. Drg. No : Date:


ROTARY KILN

BASE PLATE ALIGNMENT

CUSTOMER : NATAL PORTLAND CEMENT COMPANY SIZE :3.95diaX 61mts long


SITE: SIMUMA PLANT
KWAZULU - SOUTH AFRICA EQUIPMENT No : 431KL100

PRE HEATER
X
a b Dimensions
Position
A x y B Calculated Actual
A
B
X X C
D
E
F

X X a
b
c
d
c d e
D f
C
x
X X y
x1
y1

X X Note :
1. All measurements are to be
taken when the base plates are
not affected by sunlight.

2.Tolerance in distance between


E e f F base plate is +/- 2mm with
respect to drawing dimension

X X

X X
x1 y1
FLSMIDTH M&R NATAL

Ref. Drg. No : Date:

ROTARY KILN

BASE PLATE ALIGNMENT

CUSTOMER : NATAL PORTLAND CEMENT COMPANY SIZE :3.95diaX 61mts long


SITE: SIMUMA PLANT
KWAZULU - SOUTH AFRICA EQUIPMENT No : 431KL100

Datum line

PIER # 3 PIER # 2 PIER # 1


EL 0.00mts

Note :
1. Base plate top elevation is to be measured with respect to 0.00 mts level.
2. Tolerance in elevation after the foundation bolt tightening is +/- 0.5mm.
FLSMIDTH M&R NATAL

Ref. Drg. No : Date:


Tolerance for the S clearance is +0.1mm/ -0.0 mm

FLSMIDTH M&R NATAL

Ref. Drg. No : Date:


FLSMIDTH M&R NATAL

Ref. Drg. No : Date:


This is only a covering sheet.
Tolerance in Radial run out is 2.5mm

FLSMIDTH M&R NATAL

Ref. Drg. No : Date:


Tolerance in Supporting block run out is 0.25mm

FLSMIDTH M&R NATAL

Ref. Drg. No : Date:


FLSMIDTH M&R NATAL

Ref. Drg. No : Date:


FLSMIDTH M&R NATAL

Ref. Drg. No : Date:


431KL100
431KL100

Datum line