Rated Working Closing Volume Opening Volume Against RWP
BOP Stack Description Bore Size (in) Pressure (psig) (Gal) (Gal) Closing Ratio (psig)
= 33.59 Gallons
For a standard surface system, the minimum FVR IS 100 % of the power fluid volume required to close, at zero wellbore pressure, the ram BOPs and one annular
BOP, and to open one side outlet valve(s)
Environmental Conditions
Surface Temperature at Precharge 70 °F
1
Surface Accumulator Bottles (15 gallons)
13.7 gal Gas Type Nitrogen
Gas Volume per Bottle Pressure rating of Bottles 3000 psig
Condition 0 Data
Optimum Precharge = 1.0 /(1.5/P2-0.5/P1) 1214.7 psia 1200 psig @ 70°F
Input Precharge Pressure at Surface Cond.0 @T1 70 °F 1000 psig 1014.7 psia
Pressure at maximum temperature @T2 140 °F 1132 psig 1146.9 psia
Pressure at maximum temperature with ideal gas law P2= P1 X T2/T1
SUMMARY
Precharge
# OF BOTTLES Pressure psig Temperature ° F
Surface Accumulator 8 1000 70
Liquid Volume ,gal ACTUAL WITH VOLUME FACTOR FVR Meets req' ts ?
Condition 1:- Charged 72.71
Condition 2:- MOP 36.18
FROM CONDITION 1 TO 2 ; PRESSURE DESIGN 72.71 72.71 33.59 YES
Condition 3:- Fully Charged 0
FROM CONDITION 1 TO 3 ; VOLUME DESIGN 72.71 36.5 33.59 YES
2
SIZING THE RESERVOIR
AS Per Return-to-Reservoir Hydraulic Reservoirs 16D 4.2.4.2
The Hydraulic fluid resevoiir usable capacity shall be at least twice the stored hydraulic fluid capacity of the accumulator system.
NOTE;-
1.
2. Air vents control
offshore shall besystem
insalledshall
of sufficient size to avoid
have an audiable and overpressurization of thelow
visible alarm to indicate tank
fluid level activates between 30%--45% usable
capacity remaining.
3. The alarm shall be sound and illuminate at the unit, driller panel and minimum of one auxiliary remote panel
4. As an option a low level alarm/ cutoff may be provided to shut down the pumps before cavitation can occur.
a. With the accumulators isolated from service and with one pump system or one power system out of service,
the remaining pump system(s) shall have the capacity to, within two minutes: close one annular BOP on open hole,
open the hydraullically operated choke valve(s), and provide final pressure at least equal to the greater of the
minimum operating pressure recommended by the manufacturer(s) of both the annular BOP and choke valve(s).
NOTE: Each pumping system must have a hydraulic output capacity equal to or greater than whichever
flowrate is greater; the "Total Main Pump Rate" divided by 2 or the "Minimum Pump Rate Required".
Using the pump model combinations shown below provides Pump Output
equal to or greater than requirements of previous step:
As Per
Air APIpump
driven 16D 5.1.2.2
systems shall be capable of charging accumulators to system rated working pressure with 75 psi
air supply to drive the pump.
As per API 16 D 5.1.2.3 each pump system shall be protected from overpressurization by a minimum of two(02) devices
a. one device shall ensure that the pump discharge pressure does not exceed the the system rated working pressure.
b. The second device , normally a relief valve, shall be set to relieve at not more than 10% above system rated pressure.
Notes:
1. Each air pump requires 240 scfm at 75 psi. minimum.
3
AS per API
Primary 16 D shall
pumps 5.1.2.4
automatically start when the actual system working pressure has decreased to approximately 90%of the system rated working pressure ,
and automatically stop between 97%-100% of the system rated working pressure
Secondary pumps shall provide opeartion similar to the primary pumps , except that the set point to start the pump
may be adjusted slightly lower so that both pumps systems do not start simultaneously. The seconadry pump control shall not stop the pump at less that 95%
of the system rated working pressure and shall start the pump automatically prior to the pressure decreasing below 85% of the system rated working pressure.
Application Specifications: