Professional Documents
Culture Documents
THERMAL POWERTECH CORPORATION INDIA LIMITED conformity with the Contract specifications and requirements. The Vendor /
Contractor is responsible for correctness of design calculation and details.
Approval of this document does not relieve the Vendor / Contractor of his
responsibility in carrying out the work correctly and fulfilling the complete
requirements of the contract nor does it limit the purchaser's rights under the
Signature Initials: AS
OWNER’s ENGINEER :
FICHTNER Consulting Engineers (India) Private Limited
Chennai, India
BTG CONTRACTOR:
DONGFANG ELECTRIC CORPORATION LIMITED
Chengdu, China
Sub Contractor:
Northwest Electric Power Institute Of Commissioning
Xian, China
Document Title:
24th Dec.
2 刘立鹏 郁翔 王永庆 苏耕
2015
Date Rev Prepared by Checked by Reviewed by Approved by Details of Rev
Performance Test Procedure (CPU) Rev.2
CPU 性 能 试 验 程 序
Performance Test Procedure
( CPU )
DECL-PGT-004 1/4
Performance Test Procedure (CPU) Rev.2
1. Test purpose
To Check the performance of CPU.
2. Test items
2.1 PH value of effluent discharge from CPU.
2.2 Guarantee value: PH~8.5.
4. Test Conditions
a) The unit shall be maintained stable operation during the performance test.
b) During the test, CPU should be run smoothly more than 80% designed capacity.
c) Sampling should not less than 3 times with an interval of 10 minutes.
5. Sampling Points
Sampling point should be located in outlet of mixed bed or discharge header.
Sampling point
discharge header.
Out
6. Test Instruments
仪 器 名 称 示值误差 示 值 重 复 性 输入阻抗引起的示值误差 仪器示值总误差
DECL-PGT-004 2/4
Performance Test Procedure (CPU) Rev.2
10
11
8. example 算例
pH 7.94
DECL-PGT-004 3/4
Performance Test Procedure (CPU) Rev.2
9. 附录 Appendix
性能试验工况认可书
unit:No. Unit for Indian Krishnapatnam 2×660MW Super Critical Coal-fired Power Plant
conditions;
○试验用仪器、仪表已全部经过校验合格、工作正常、有效,可以用于本次试验;
All instruments and meters required by the test are all checked and qualified after
确认签字:Confirmed by signature:
○试验数据完整、准确、真实、有效。各方均保留一份原始数据文件一套备案;The data
of the test is complete, accurate, true and effective. Various parties maintain one document
试验结束确认
of original data for records;
Confirmation at
○各方均同意结束本次试验测试。Various parties agree to complete this test
end time of the
试验结束时间:End time of the test:
test
确认签字:Confirmed by signature:
DECL-PGT-004 4/4