You are on page 1of 1

A Load 2700

Moment x-dir y-dir


Bottom 0 29
Top 6 137

Col Type Rectangular Column (reinf. on 2 sides)

x-dir y-dir
Unsupported Length 8250 8250
Col Size 200 900
d'/D 0.05 0.20
d' 40

Concrete 20
Steel 415

Effective Length Ratio


0.80 from IS Code
0.90 manual Calculation
Effective Length to be considered from Manual Calculation
Effective Length (le) lex Ley
7425 7425
E Slenderness Ratio
le/D 8 Short Column
le/b 37 Slender Column
Moment due to Slen Muax 0
Muay 372

Min Ecc ex 46.5


ey 23.2
Moment due to ecc Mux 125.55
Muy 62.55

G Reduction of Moments
Percentage assumed 2.18
Asc 3924

Puz 2841

k1 K2 Pb
x-x 0.219 0.096 367
y-y 0.184 -0.022 291

Kx 0.06
Ky 0.06

Additional Moments due to ecc Max 0


May 21

Modified Initial Moments Mux 3.6


Muy 70.6

Summary of Moments
A Moment due to eccentricity + Modified additional moments
Mux 126
Muy 83

B Modified initial moments + Modified additional moments


Mux 4
Muy 91

C 0.4Muz + Modified additional moments


Mux 0
Muy 32

Final Design Loads


Pu 2700
Mux 126
Muy 91

# Sensitivity : This Document is Classified as "LNT Internal Use".

You might also like