SPECIFICATION FOR INCINERATOR MODEL BGW-20

1. Features
(1) An air atomizing burner is applied to make stable combustion, even though waste oil includes 40-percent water.
(2) An auxiliary burner is applied to make perfect combustion, even though waste oil includes 40-percent or more water.
(3) An ejector is applied and internal pressure is kept to be negative, so that a solid material (include a solid waste of high
molecular) such as waste cloth may be put into with safety and ease.
(4) A burner nozzle has a 3mm orifice size against blockade.
(5) By erosion-proof castable lining, furnace is protected from high temperature and chlorine gas with high molecular solid
waste (plastics etc. ) burning disposal, and be proof against hard use.
(6) An automatic combustion device is utilized for handy operation.
(7) Other various devices are designed for safe operation.

2. Main Specification
4
01. Waste Oil Burning Capacity : 20x 10 kcal/h
02. Allowable Back Pressure at Funnel Base : 30 mmAq
03. Electric Source : AC440 Volt / 60 Hz / 3 φ
04. Total Electric Capacity ; 2.9 KW
05. Control System ; Automatic Control System
06. Total Weight : 730 kg
07. Setting Dimension (Height x Width x Depth) ; 1650 x 870 x 1340
08. Color of Casing : Silver
09. Color of Control Box ; M 2. 5G 7/2
10.Fuel Oil for Aux. Burner ; A Oil
2
11. Atomizing Air Press. for Waste Oil Burner : 1 - 10 ( Max.10 ) kg/cm

3. Specification In Detail
01. Furnace
a. Furnace Volume : 0.176 m3
b. Inside Construction ; Castable Lining
02. Waste Oil Burner
a. Type ; Air Atomizing Burner
b. Orifice Dia. of Nozzle ; 3 mm
2
c. Air Pressure ; 0.5 kg/cm
3
d. Atomizing Air Flow ; 0.35 Nm /min
03. Auxiliary Burner
a. Type ; Gun-type Burner
b. Fuel Oil ; A Oil
c. Capacity ; 5.0 ltr/hr
2
d. Fuel Oil Atomizing Pressure ; 7 kg/cm
e. Nozzle Tip ; 1.5 G
f. Ignition System ; High Voltage Sparking System
g. Flame Detector ; Flame Eye (cds)
04. Fuel Oil Pump Aux. Burner
a. Type ; Solenoid Pump
b. Delivery Presure ; 7 kg/cm2
c. Electric Power ; 0.03 KW, AC 110 V Single Phase
05. Cooling Fan
a. Type ; Turbo-fan
b. Capacity ; 7 Nm3/min
c. Delivery Pressure ; 200 mmAq
d. Motor ; 2.2 KW, 4.0 A, 2 Poles, AC440V, 60 Hz, 3φ, 3460 rpm
06. Flange Funnel Base ; 300A (JIS5K Flange)
07. Inlet Flange of Waste Oil Line ; 25A (JIS5K Flange)
08. Return Flange of Waste Oil Line ; 20A (JIS5K Flange)
09. Inlet Flange of Aux. Burner Oil Line ; 15A (JIS5K Flange)
10. Inlet Flange of Atomizing Air Line ; 15A (JIS10K Flange)
11. Waste Oil Pump
(a) Type ; Gear Type
(b) Discharge Capacity ; 150 ltr/hr
(c) Discharge Pressure ; 1 kg/cm2
(d) Motor ; AC110V, 60 Hz, 1•, 0.09 KW, 300 rpm
12. Waste Oil Strainer
(a) Type ; Single Type (JIS10K-25A Flange 10 Mesh)

4. Safety Devices
(1) In the event of misfire and flame failure of the pilot burner, or flame failure of the waste oil burner, the
combustion circuit is cut off.At the same time, the pilot lamp comes on and the bell rings.
(2) If the fuel. oil' pressure of the pilot burner drops, the combustion circuit is cut off . At the same time, the pilot
lamp comes on and the bell. rings .( Set pressure : 4 kg/cm2 )
(3) If the air pressure of the waste oil burner drops, the combustion circuit is cut off. At the same time, the pilot lamp
comes on and the bell rings. ( Set pressure : 0.1 kg/cm2 )
(4) If the cooling fan abnormal stops, the running is stoped . At the same time, the pilot, lamp comes on and the bell
rings.
(5) For during the combustion, If the solid waste supplying port is opened, the combustion circuit is cut off. At the
same time, the pilot lamp comes on and the bell rings.
(6) If the temperature of exhaust gas abnormally increases, the combustion circuit is cut off. At the same time, the
pilot lamp comes on and the bell rings. (Set-temperature : 350ºC )
(1) to (5) are shown one lamp
(7) When the running is stoped or the combustion circuit is cut off, they reseted manually. if not they cannot restart.
(8) In case that every system on the plant is powerless because of interruption of electric supply, certainly press the
running switch again after recovering. Failure to do so will not allow the burners to restart automatically.
(9) In case that; is happens trouble in the neighborhood of the incinerator, it can strop the incinerator by the remote
emergency stop switch.