266.5 m T.B.L
h
1 D 3
d
FOUNDATION 218 m 3
LEVEL A B C
4.2 4.5 33
b= 41.7 m
46 m a
Full uplift
7.2 m 34.5 m
15.333 m b a
30.667 m c
Normal uplift
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
X= SM / S V =(62321.4728/2374.635)= 26.245 m
e= (b/2)-X =(41.7/2)-26.245= -5.395 m
-5.395 m
6e/b= =(6*-5.395)/41.7= -0.7763
Stress at toe: =2374.635*(1+-0.7763)/41.7= 12.7387 t/m2
Stress at heel: =2374.635*(1--0.7763)/41.7= 101.153 t/m2
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
2.Weight of water:
As per condition II case (a) 105.00 4219.74
3.Hydrostatic pressure:
a) 0.5 46.00 46.00 1.00 1058.00 15.33 16222.67
4.Uplift pressure:
a) 0.5 34.50 15.33 1.00 -264.50 23.00 -6083.50
b) 1 7.20 15.33 1.00 -110.40 38.10 -4206.24
c) 0.5 7.20 30.67 1.00 -110.40 39.30 -4338.77
1994.33 1058.00 51912.71 16222.67
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
2.Weight of water:
a) 1 4.20 4.00 1.00 16.80 39.60 665.28
b) 0.5 4.20 42.00 1.00 88.20 40.30 3554.46
3.Hydrostatic pressure:
a) 0.5 46.00 46.00 1.00 1058.00 15.33 16222.31
4.Uplift pressure:
a) 0.5 34.50 15.33 1.00 -264.50 23.00 -6083.50
b) 1 7.20 15.33 1.00 -110.40 38.10 -4206.24
c) 0.5 7.20 30.67 1.00 -110.40 39.30 -4338.72
1994.34 1058.00 51912.75 16222.31
As per IS 1893-1975 the design value of Horizontal seismic coefficient a (h) in the
seismic coefficient method shall be computed as given by the following expression
a(H)= b *I* a(0) Clause 3.4.2.3.(A)
b =1 I= 3 a(0) = 0.02
a(H)= =(1*3*0.02)= 0.06
As per clause 7.3.1 earthquake forces, for dams upto 100m height, the Horizontal
seismic coefficient shall be taken as 1.5 times seismic coefficient a (H) in 3.4.2.3(a)
at the top of the dam reducing linearly to 0 at the base. Vertical seismic coefficient shall be
taken as 0.75 times seismic coefficient a (H) at the top of the dam reducing linearly
to 0 at the base.
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
266.5
component Height from base a(H)= a(V)=
of dam to C.G.of
the component
For masonry portion:
I 14.00 0.0260 0.0130 48.5
II 24.25 0.0450 0.0225
III 14.67 0.0272 0.0136
For water :
a 44.00 0.0816 0.0408 218
b 28.00 0.0520 0.0260
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
AT El. 218
Y= 46 m
h= 46 m
Cs= =(0.69574/2)*(46/46)*(2-46/46)+(46/46*(2-46/46))^0.5= 0.69574
P= Cs * a (h)*W*h =0.69574*0.09*1*46= 2.8804
Vh= 0.726*P*Y = =0.726*2.8804*46= 96.1938
Mh= 0.299*P*Y^2 = =0.299*2.8804*46^2= 1822.38
AT El. 260
Y= =264-260= 4 m
h= 46 m
Cs= =(0.69574/2)*(4/46)*(2-4/46)+(4/46*(2-4/46))^0.5= 0.19975
P= =0.19975*0.09*1*4= 0.82697
Vh= =0.726*0.826965*4= 2.40151
Mh= =0.299*0.826965*4^2= 3.9562
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
2.Weight of water:
Vertical acceleration:
a) 0.959 4.20 4.00 1.00 16.11 39.60 638.12
b) 0.487 4.20 42.00 1.00 85.91 40.30 3462.12
4.Hydrostatic pressure:
0.5 46.00 46.00 1.00 1058.00 15.33 16222.67
5.Vertical component of Hydrodynamic forces:
a) 9.38 371.42
6.Uplift pressure:
a) 0.5 41.70 46.00 1.00 -959.10 27.80 -26662.98
1490.28 1227.50 39129.61 19333.16
SM= =(39129.61-19333.16)= ### t.m
SV= 1490.28 t
X= SM / S V =(19796.45/1490.2844)= 13.28 m
e= (b/2)-X =(41.7/2)-13.28= 7.57 m
6e/b= =(6*7.57)/41.7= 1.09
Stress at toe: =1490.2844*(1+1.09)/41.7= 74.69 t/m2
Stress at heel: =1490.2844*(1-1.09)/41.7= -3.22 t/m2
CONDITION V: RESERVOIR AT F.R.L. WITH EARTHQUAKE FORCES
b) With normal uplift:
Sl.No. DESCRIPTION FORCES MOMENTS
Coeff. L H Unit wt. V H L.A Positive Negative
1.As per previous calculationupto Sl.No.6
2449.38 1227.50 65792.59 19333.16
2.Normal uplift:
a) 0.5 34.50 15.33 1.00 -264.50 23.00 -6083.50
b) 1 7.20 15.33 1.00 -110.40 38.90 -4294.56
c) 0.5 7.20 30.67 1.00 -110.40 39.30 -4338.72
1964.08 1227.50 51075.81 19333.16
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
(W-u) TANf + CA
F= FP FC
P
Where F = Factor of safety against sliding.
W = Total mass of the dam
U = Total uplift pressure.
TANf Coefficient of internal friction of the material.
=
C = Cohesion of the material at the plane considered.
A = Area under consideration for cohesion
Fp = Partial factor of safety in respect of friction.
Fc = Partial factor of safety in respect of cohesion
P = Total horizontal force.
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
2.Weight of water:
a) 1 0 4.00 1.00 0 0 0
b) 0.5 0 0 1.00 0 0 0
2.Hydrostatic pressure:
a) 0.5 4.00 4.00 1.00 8.00 1.33 10.67
3.Uplift pressure:
a) 0.5 6.00 4.00 1.00 -12.00 4.00 -48.00
58.73 8.00 207.73 10.67
3 3
6
1.33 b a
4
2.667 c
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
2.Weight of water:
a) 1 0 4.00 1 0 0 0
b) 0.5 0 0 1 0 0 0
2.Hydrostatic pressure:
a) 0.5 4.00 4.00 1.00 8.00 1.33 10.67
3.Uplift pressure:
a) 0.5 3.00 1.33 1.00 -2.00 2.00 -4.00
b) 1 3.00 1.33 1.00 -4.00 4.50 -18.00
c) 0.5 3.00 2.67 1.00 -4.00 5.00 -20.00
60.73 8.00 213.73 10.67
2.Weight of water:
a) 1 0 4.00 1.00 0 0 0
b) 0.5 0 0.00 1.00 0 0 0
2.Hydrostatic pressure:
a) 0.5 4.00 4.00 1.00 8.00 1.33 10.67
3.Uplift pressure:
a) 0.5 3.00 1.33 1.00 -2.00 2.00 -4.00
b) 1 3.00 1.33 1.00 -4.00 4.50 -18.00
c) 0.5 3.00 2.67 1.00 -4.00 5.00 -20.00
60.73 8.00 213.73 10.67
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
266.5
component Height from base a(H)= a(V)= 40 42
of dam to C.G.of
the component 45.5
For masonry portion:
I 45.25 0.08397 0.04198 48.5
II 42.6667 0.07918 0.03959 218
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
AT El. 260
Y= 4 m
h= 46 m
Cs= =(0.73/2)*(4/46)*(2-4/46)+(4/46*(2-4/46))^0.5= 0.2096 7.5456
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
2.Weight of water:
Vertical acceleration:
a) 1 0.00 4.00 1.00 0.00 0.00 0.00
b) 0.5 0.00 0.00 1.00 0.00 0.00 0.00
4.Hydrostatic pressure:
0.5 4.00 4.00 1.00 8.00 1.33 10.67
5.Vertical component of Hydrodynamic forces:
a) 0.00 0.00
6.Uplift pressure:
a) 0.5 6.00 4.00 1.00 -12.00 4.00 -48.00
55.76 16.44 197.00 33.36
SM= =(197-33.36)= 163.64 t.m
SV= 55.76 t
X= SM / S V =(163.64/55.76)= 2.93 m
e= (b/2)-X =(6/2)-2.93= 0.07 m
6e/b= =(6*0.07)/6= 0.07
Stress at toe: =55.76*(1+0.07)/6= 9.94 t/m2
Stress at heel: =55.76*(1-0.07)/6= 8.64 t/m2
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
(W-u) TANf + CA
F= FP FC
P
Where F = Factor of safety against sliding.
W = Total mass of the dam
U = Total uplift pressure.
TANf =Coefficient of internal friction of the material.
C = Cohesion of the material at the plane considered.
A = Area under consideration for cohesion
Fp = Partial factor of safety in respect of friction.
Fc = Partial factor of safety in respect of cohesion
P = Total horizontal force.
(W-u)= 58.73 C= 35 A= 6 m2
+ CA
F= =(70.725*0.75/1+((35*6)/1.2))/8= 5.50547 >1.0 FC
P
CASE (2) NORMAL UPLIFT:
P= 8 TANf = 0.75 Fp= 1.5 Fc= 3.6
W-u= 60.73 C= 35 A= 6 m2
(W-u)= 70.73 C= 35 A= 6 m2
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
(W-u)= 73.69 C= 35 A= 6 m2
(W-u)= 55.76 C= 35 A= 6 m2
(W-u)= 57.76 C= 35 A= 6
(III) Typical Design of Various Irrigation Structures - Non spillway (Design) Page No.
PWD, WRO
Irrigation Design Handbook
HYDRAULIC PARTICULARS:
TBL 266.5 m
MWL 264 m
FRL 264 m
U/S Slope starting place: 260 m
D/S Slope starting place: 262 m
Foundation Level: 218 m
U/S Slope: 0.1 :1
D/S Slope: 0.75 :1
Distance from gallery: 3 M
Unit weight of masonry: 2.3 t/m3
Unit weight of water: 1 t/m3
Top width of non spillway: 4.5 m
Earth quake forces: a(0) 0.02
For dams with combination of vertical and sloping faces, an equivalent slope
may be used for obtaining the approximate value of Cs.The equivalent slope may be
obtained as given below.(vide fig.10 of IS 1893 -1984)
(III) Typical Design of Various Irrigation Structures - Non spillway (Stability Analysis) Page No.
PWD, WRO
Irrigation Design Handbook
a(h) a(v)
0.09 0.045
44 0.081649 44 0.040825
28 0.051959 28 0.025979
14 0.025979 14 0.01299
(III) Typical Design of Various Irrigation Structures - Non spillway (Stability Analysis) Page No.