ANJANI PORTLAND CEMENT LIMTIED

Ref No. OPER/SOP-14 Dept: Operations


Supersedes Nil Page : 1 of 1
Next Review Effective
Version No./Dt. 01/01.03.2018 Rev.No./Dt 00/01.03.2018 28.2.2021 01.03.2018
Dt. Dt.

Title Standard Operating Procedure for manometer operation

1.0 Purpose:
To give guide lines for usage of manometer.

2.0 Scope:
Applies to manometer
3.0 Responsibility:
HOS Operation and Process Engineer, is responsible for implementation of this SOP.

4.0 Procedure

For static pressure measuring


1. Clean the Pitot tube either puffing air.
2. Connect the one port of Pitot tube with one port of Manometer
3. Make zero calibration for the manometer for atmospheric condition by pressing “ZERO” button.
4. Insert the Pitot horizontally (Perpendicular to gas flow direction) to the measuring port.
5. Close the exposed portion of measuring port with waste cloth or gloves to avoid external air entry
and to provide undisturbed measuring conditions
6. Wait for few seconds and start observing the measured digital data in the manometer.

7. Note down the constant, consistent and stable data of static pressure.

EnMS;

1. Calibrate the equipment before due date of calibration


2. Un authorized not allow to use this equipment
3. Calculate the service life equipment for procurement
4. Avoid the Idle use of equipment

Prepared by Reviewed for adequacy and approved by Authorized by