You are on page 1of 4

Anchor Rod Shear and Tension - As Per AISC LRFD

LRFD Spec Requirements :


The LRFD Specification defines the Anchor rod (Bolts) Shear and Tension limit states in section J3.6 & J3.7
and Table J3.2 & J 3.5

Anchor Bolt diameter = 16 mm


= 0.63 inch

Anchor Bolt Grade = A325


From Table J3.2
Nominal Shear Strength Fv = 54 KSI
Nominal Shear Strength FT = 90 KSI
Number of Bolts taking Shear = 4 Nos
Number of Bolts Taking Tension = 2 Nos
Anchor Rod resistance factor Ø = 0.75
From STAAD, 2062
MAXIMUM TENSION LOAD, = 20 KN
SHEAR = 21 KN
SHEAR = 11 KN
Resultant = 23.71 KN

calculated Shear Strength of bolt Group V ub = 50.46 Kips


= 224.45123 KN >
Hence OK

calculated Tensile Strength of bolt Group T ub = Ø Ft Ab


= 42.05 Kips
= 187.04269 KN >

Since the Percentage is less than 30 percentage combined shear and Tebnsion need not be checked. 16.1-1.34 LRFD

Anchor Rod Shear Stress fv = Vu / Number of Bolts X A


= 4.27761

Nominal Tensile Strength Ksi = 117


Table J3.5 = 110.58

calculated Tensile Strength of bolt Group T ub Ø Ft Ab


=
= 51.66829
= 229.82
Hence OK
V ub Ø Fv A b

T ub Ø Ft A b

23.71 KN
5.33 KIPS 0.11 Percentage

20 KN
4.50 KIPS 0.11 Percentage
ked. 16.1-1.34 LRFD

Vu / Number of Bolts X Area of Anchor Bolt


Kips
NEED NOT BE CHECKED

- 1.5 fv ≤ 90
Kips ≤ 90

Ø Ft Ab
KIPS
kN > 20 KN
Anchor Rod Shear and Tension - As Per AISC LRFD

LRFD Spec Requirements :


The LRFD Specification defines the Anchor rod (Bolts) Shear and Tension limit states in section J3.6 & J3.7
and Table J3.2 & J 3.5

Anchor Bolt diameter = 16 mm


= 0.63 inch

Anchor Bolt Grade = A325


From Table J3.2
Nominal Shear Strength Fv = 54 KSI
Nominal Shear Strength FT = 90 KSI
Number of Bolts taking Shear = 4 Nos
Number of Bolts Taking Tension = 2 Nos
Anchor Rod resistance factor Ø = 0.75
From STAAD, 2062
MAXIMUM TENSION LOAD, = 54 KN
SHEAR = 15 KN
SHEAR = 5 KN
Resultant = 15.81 KN

calculated Shear Strength of bolt Group V ub = 50.46115692 Kips


= 224.45123 KN >
Hence OK

calculated Tensile Strength of bolt Group T ub = Ø Ft Ab


= 42.05 Kips
= 187.04269 KN >

Since the Percentage is less than 30 percentage combined shear and Tebnsion need not be checked. 16.1-1.34 LRFD

Anchor Rod Shear Stress fv = Vu / Number of Bolts X A


= 2.853008

Nominal Tensile Strength Ksi = 117


Table J3.5 = 112.72

calculated Tensile Strength of bolt Group T ub Ø Ft Ab


=
= 52.66672
= 234.26
Hence OK
V ub Ø Fv A b

T ub Ø Ft A b

15.81 KN
3.55 KIPS 0.07 Percentage

54 KN
12.14 KIPS 0.29 Percentage
ked. 16.1-1.34 LRFD

Vu / Number of Bolts X Area of Anchor Bolt


Kips
NEED NOT BE CHECKED

- 1.5 fv ≤ 90
Kips ≤ 90

Ø Ft Ab
KIPS
kN > 54 KN

You might also like