Professional Documents
Culture Documents
Accnt: NICSI
Delhi
A DISMANTLING WORKS
Note:
a) All dismantling works shall include the cost of dismantling,
stacking of re-usable materials, carting away debris to outside
the premises to the place designated by the local authority by
mechanical transport etc., complete.
B FLOORING WORKS
Note:
a) The contractor has to check the existing floor for perfect level
before laying the Granite / vitrified/ceramic or any other
floorings. All local undulations are to be leveled which may be
included in the quoted rate.
FLOORING TOTAL -
C PARTITIONS / DOORS
C1 PARTITIONS
Note:
a) All partition thickness and material used for partition frame
work/cladding shall be as per detailed drawings.
b) The gyp partitions may have grooves of 6mm wide as detailed
and the quoted rate shall include the cost of the same if
applicable
c) The measurement of partition will be upto the false ceiling
bottom and paid for.
Framework:
Partition frame work to be formed out of 50 X 25mm
aluminum frame work placed vertically and horizontally at
610mm centre to centre and cross braced with 50mm floor
and ceiling channels. The cross bracing channels shall be
provided also at above and below the glass in partition
framework and to be secured to floor at bottom and to any
nearest structural member using galvanized metal screws and
wooden / PVC rawl plugs.
Cladding:
Infill:
As an acoustic requirement contractor is to consider partition
frame cavity to be packed with 50mm thick rockwool blanket
of density 24kg/m³ suitably affixed to partition framework
using GI binding wire and duct tape.
Special Provisions:
Contractor to make cutouts for all electrical, networking boxes
as shown in the drawing.
1,650 RFT
D FALSE CEILING
Note:
a) Rate quoted to include for providing necessary cut-outs for
fixing light fixtures (for all sizes) AC diffusers, AC dampers,
AC linear grilles, smoke detectors, speakers, etc., and
strengthening of the framework required at the cut-outs and
all requirements of M&E contractors for fixing their
components.
b) Gypsum false ceiling may have verticals depending on details
and site conditions. The rates may be quoted accordingly.
Rate quoted to include vertical drops upto 150mm and all cut-
outs required for light fixtures, smoke detectors and other
services etc., complete.
The quoted rate shall include the cost of providing and fixing
axioms, shadow angles etc., and making cut-outs with
additional framework wherever required for electrical fixtures,
AC grills, diffusers & access panels etc., complete.
GRID SYSTEM:
Type : 15mm Plain Grid
System : Hot dip Galvanized Steel System
Main Runner: 15mm x 42mm x 3000mm
CrossTee: 15mm x 42mm x 600mm
Wall Angle : 19mm x 19mm x 3000mm
The quoted rate shall include the cost of providing and fixing
axioms, shadow angles etc., and making cut-outs with
additional framework wherever required for electrical fixtures,
AC grills, diffusers & access panels etc., complete.
GRID SYSTEM:
Type : Silhoutte Grid with black reveal
System : Hot dip Galvanized Steel System
Main Runner: 15mm x 42mm x 3000mm
CrossTee: 15mm x 42mm x 600mm
Wall Angle : 19mm x 19mm x 3000mm
E FURNITURE
1 CABINS
1.1 Providing and fixing of pinup board of size : 4' 0" x 3' 0" 3 Nos
Pinup board made of 12mm softboard/cellotex boards
covered with fabric of range Rs.250/Mtr including necessary
incidental hardware and necessary wooden beading all-round.
6 MEETING:
6.1 Magnetic writing board 3 Nos
Dim: 8' 0"x4' 0"
P/F ceramic magnetic marker board in matt finish of above
size complete in all respects with a set of starter kit as per
architect's instructions complete for writing and magnetic
display. Cost to include wooden molding all-round finished
with melamine polish with all incidental hardware like nails,
screws etc.
7 LIBRARY
7.1 Pin-up board 1 No
Dim: 6' 0" x 4' 0".
Pinup board made of 12mm softboard/cellotex boards
covered with fabric of range Rs.250/Mtr including necessary
incidental hardware and necessary wooden beading all-round.
8 RECEPTION
8.1 Reception table including drawer unit and with corian tops 1 No
Dim: 9' 0"x 2' 0" x 3' 6" ht.
Providing and fixing Bi-level Reception table formed out of
19mm thk water & termite resistant block board of approved
make for the structure. First level top surface shall be cladded
with approved veneer / corian top as detailed. and front
modesty panel with veneer/laminate. Second level top shall
be fixed with 19mm thk toughened, edge polished glass as
per the design.
9 CAFETERIA
9.1 Granite counter - 2' 0" deep. 70 Rft
Providing & fixing 20mm/40mm thk granite counter to shape
& size as shown in the drawing using 19mm thk approved
quality granite over 19mm thk BWP ply. All exposed edges of
granite are to be highly polished with bull nosing with drip
mould.
10 REPROGRAPHIC
10.1 Counter with underneath storage 15 Rft
P/F counter of 2' 0" width made of 19mm thk water & termite
resistant BB/Ply for top & verticals. Top edge shall be
thickened to 11/2" & top & vertical edges to be covered with
wooden molding finished with melamine. All the external
surfaces shall be finished with approved laminate and
unexposed surfaces with french polish. Cut edges shall be
covered with 6mm thk TW lipping.
F MODULAR WORKSTATIONS
Note: All modular partitions / furniture may required to be covered
with heavy duty polythene paper and scotch tape.
All modular partitions / furniture may require to have heavy
duty hardware like levellers, brackets, grommets, as detailed.
1 MODULAR WORKSTATIONS
Approved Makes: Godrej/ BP Ergo/Wipro/Talin
1.1 3" thk Modular partitions of 4' 0" to 4'9" ht 7,450 Sft
Providing and installing modular workstation partitions of
75mm thk formed out of aluminium powder coated
framework. The partition tiles shall be combination of
laminated tiles & fire retardant fabric with metal sheet. The
tiles are press fit into the framework. Height of the partition is
4' 0". All partition shall be complete with two level raceways
for power, data & network cables & skirting at the bottom.
Partitions shall be complete in all respects including
Aluminium/PVC trims, heavy duty levellers etc. (Basic cost of
fabric - 250 / Mtr)
WORKSTATIONS TOTAL -
MODULAR FURNITURE:
Approved Makes: Godrej/ BP Ergo/Wipro/Talin
2 CABINS
2.1 Main table 2 Nos
Dim: 6' 6" x 2' 6".
The table shall have a Drawer unit formed out of 19mm thk
termite and water resistant MDF/PB with laminated inside &
outside. Drawer unit to have 2 regular drawers & one filing
drawer mounted on drawer channels including hardware like
handles, locks etc., complete.
The table shall have a Drawer unit formed out of 19mm thk
termite and water resistant MDF/PB with laminated inside &
outside. Drawer unit to have 2 regular drawers & one filing
drawer mounted on drawer channels including hardware like
handles, locks etc., complete.
4.2 Stright table of size: 5' 0" x 2' 0" x 2' 6" ht. 2 Nos
Providing and supplying modular work top in approved profile
of above size & shape formed out of 25mm thk MDF/PB
finished with approved colour veneer/laminate with post
formed edge. Table top is to be supported by cantilever MS
powder coated heavy duty brackets and provided with PVC/SS
grommet for wire management.
5 DISCUSSION:
5.1 Discussion table 2 Nos
Dim: 3' 0" x 3' 0" x 2' 6"
Providing & fixing discussion table made to shape & size using
25mm thk MDF/PB of approved make finished with approved
colour veneer / laminate with 3" x 2 1/4" thk teak / steam
beech wooden molding for the edge finished with melamine
polished. Table top shall be mounted on pedestal formed out
of SS/ MS powder coated base as detailed.
6 MEETING:
6.1 Meeting room table 3 Nos
Dim: 6' 0" x 3' 6" x 2' 6" ht.
Providing & fixing meeting room table made to shape & size
using 25mm thk MDF/PB of approved make finished with
approved colour veneer / laminate with 3" x 2 1/4" thk teak /
steam beech wooden molding for the edge finished with
melamine polished. Table top shall be mounted on pedestal
formed out of SS/ MS powder coated base as detailed.
7 LIBRARY:
7.1 Library table 2 Nos
Dim : 3' 0" x 3' 0" x 2' 6" ht.
Providing & fixing Library table made to shape & size using
25mm thk MDF/PB of approved make finished with approved
colour veneer / laminate with 3" x 2 1/4" thk teak / steam
beech wooden molding for the edge finished with melamine
polished. Table top shall be mounted on pedestal formed out
of SS/ MS powder coated base as detailed.
STORAGES (MODULAR)
1.07 Modular Medium height Storages (workstation area). 450 SFT
Dim: 1' 6" deep x 4' 0" to 4'9" ht.
Providing, Fabricating & fixing of knock down type 4' 0" ht
storages in required lengths, made of 19mm thk post
formed/PVC edge banded prelaminated MDF for structure,
doors & shelves. All the surfaces shall be finished with
approved veneer laminate & balancing lamination with post
forming for the shutters, top and shall be fixed with spring
loaded hinges & provided with all accessories like
multipurpose locks, handles, tower bolts, magnetic catch etc
complete.
STORAGES TOTAL -
H CHAIRS
1.01 High back revolving chairs with knee tilt, height & width
adjustable arm rest, head rest and multiple locking. 40 Nos
Location: Conf, Cabins.
CHAIRS TOTAL -
J CARPET FLOORING:
CARPET FLOORING -
K SOFAS
1.05 Same as above Side Tables of size 2' 0"x2' 0" : 2 NOS
Side table of 18" dia with 12mm thk glass top. Top shall be
supported by powder coated metal pedestal/SS legs as per
the design. Glass to have high mirror polished edge & 25mm
wide beveling.
SOFAS TOTAL -
L BLINDS
BLINDS TOTAL -
a) 15 mm dia RO RFT
b) 20 mm dia RO RFT
c) 25 mm dia RO RFT
d) 32 mm dia RO RFT
a) 15 mm dia RO RFT
b) 20 mm dia RO RFT
c) 25 mm dia RO RFT
d) 32 mm dia RO RFT
1.03 Providing & fixing full way lever operated forged brass
ball valve of brass body with forged brass hard chromeplated
steel ball tested to a pressure not less than 15 Kg / sqcm with
threaded / flanged joints complete with nuts, bolts, gaskets,
washers etc.,
a) 15 mm dia RO RFT
b) 20 mm dia RO RFT
c) 25 mm dia RO RFT
d) 32 mm dia RO RFT
1.04 Supplying and wrapping 6mm thick vidoflex tube for thermal
insulation for Hot Water
a) 15mm dia RO RFT
b) 20mm dia RO RFT
c) 25mm dia RO RFT
d) 32mm dia RO RFT
a) 32 mm dia RO RFT
b) 40 mm dia RO RFT
c) 50 mm dia RO RFT
d) 75 mm dia RO RFT
e) 100mm dia RO RFT
1.04 Supplying, fixing & testing 110mm dia PVC soil, waste & vent
pipes (SWR) confirming to IS13592 for terrace gutter to
ground floor. RO RFT
SUMMARY
ELECTRICAL WORKS
II ELECTRICAL WORKS
A MV PANELS - -
B DISTRIBUTION BOARDS: - -
G POWER RECEPTACLES - -
H ELECTRICAL FITTINGS - -
I EARTHING - -
K MISCELLANIOUS ITEMS - -
SUB TOTAL - -
VAT@-------------% of total -
BILL OF QUANTITES
A MV PANELS
Design as per drawings, manufacture, supply, store,
erect in proper position, testing and commissioning of
following MV Panels and extendable type front operated,
dead back having Bottom Bus-Bars and Cable entry as
per site conditions. The panels shall be fabricated using
14 gauge CRCA sheet steel for main frame, door
and partitions, dust and vermin proof lockable doors
and carrying the control wiring using FRLS colour coded
copper conductor PVC insulated Wires and using push on
terminals. The panel shall be floor / wall mounting type
depending on the site conditions, all complete with
interconnections by using electrolytic grade tinned
copper Bus Bars of 99.95% purity, colour coded heat
shrinkable PVC sleeves.
MV PANELS TOTAL - -
B DISTRIBUTION BOARDS:
Factory fabricated Metal double door distribution boards
of approved make with all the accessories like din rails
for mounting MCB's, lugs, earth & neutral busbars,
ELCBs, MCBs of 9/10kA with 'C' / D Curve characteristics
etc. The DBs shall have compartmentalised chambers for
each phase.
The rates shall include fixing of DB on wall including
extension cable draw boxes, cable managers around the
DBs, angle iron fixing frames, hardware accessories, civil
works etc.
2.00 MS CONDUITING
16SWG MS conduits of following sizes with required
conduit accessories like screwed bends, collars, junction
boxes, saddles, GI fish wire etc. The installation shall
include proper threading of conduits with suitable sized
conduits as per site conditions. Providing required
ladders for the entire height (including double height
floors) of the floor is part of the work.
7.01 450mm x 75mm Raceway for network cables with cable Rmt - -
barrier in Datacenter below the false flooring.
7.02 150mm x 150mm Power feeding Raceway with cable Rmt - -
barrier in Datacenter below the false flooring.
2.00 MS CONDUITING
16SWG MS conduits of following sizes with required
conduit accessories like screwed bends, collars, junction
boxes, saddles, GI fish wire etc. The installation shall
include proper threading of conduits with suitable sized
conduits as per site conditions. Providing required
ladders for the entire height (including double height
floors) of the floor is part of the work.
7.01 450mm x 75mm Raceway for network cables with cable Rmt - -
barrier in Datacenter below the false flooring.
7.02 150mm x 150mm Power feeding Raceway with cable Rmt - -
barrier in Datacenter below the false flooring.
2.03 3C x 2.5 Sqmm copper conductor PVC insulated FRLS 2000 Rmt - -
wires overall FRLS PVC Sheethed Cable run in PVC
conduit / Raceways for UPS / power distribution.
2.04 3C x 4.0 Sqmm copper conductor PVC insulated FRLS 420 Rmt - -
wires overall FRLS PVC Sheethed Cable run in PVC
conduit / Raceways for UPS / power distribution.
G POWER RECEPTACLES
2.01 32 Amps, single phase 3-pin industrial plug and socket 2 Each - -
with DP MCB control, including the plug top.
2.02 20 Amps, single phase 3-pin industrial plug and socket 4 Each - -
with SP MCB control, including the plug top.
2.03 32 Amps, 3 phase 5-pin industrial plug and socket with 2 Each - -
TP MCB control, including the plug top.
2.04 63 Amps, 3 phase 5-pin industrial plug and socket with Each - -
TP MCB control, including the plug top.
3.01 63 Amps, single phase 3-pin industrial plug and socket 9 Each - -
with DP MCB control, including the plug top.
3.02 32 Amps, single phase 3-pin industrial plug and socket 1 Each - -
with DP MCB control, including the plug top.
3.03 20 Amps, single phase 3-pin industrial plug and socket 1 Each - -
with SP MCB control, including the plug top.
POWER RECEPTACLES TOTAL - -
H ELECTRICAL FITTINGS
The below mentioned Light fixture with Open
construction low loss electronic / copper Ballasts,
starter, HPF condenser, Low glare and with High lumens
output lamps. The installation shall be complete with all
hardwares like anchor fasteners, set of chain / drop rods
with ball & sockets, check nuts, flexible pipes with
glands etc. complete.
The rate shall also include cutting open false ceiling and
channels to the required sizes and finishing with pop
works.
Make: Philips / Wipro / GE / Thorn or Eq.
1 CFL Luminaires
1.1 2 x 36 Watts CFL, recess mouting direct / indirect 25 Each - -
luminaires with parabolic / paralite P5 louvers and with
High efficency low loss electronic digitial ballasts.
1.3 4 x 18 Watts, recess mouting darklite luminaire with low 295 Each - -
loss ballasts and with mirror optics low glare reflective
louvers.
2 FTL Luminaires
2.01 2 x 36 Watts, pendant mounted, indirect FTL luminaire Each - -
with electroninc ballasts, with required suspension
system.
2.03 Additional cost for Luminaire hangers using 20mm dia. 12 Each - -
16SWG MS Drop rods of length ranging between 1.2 to
2.2 mt. with required accessories like MS clamps / cross
supports made out of 3mm thick angles suitable to hang
the fittings from the ceiling frame wires
2.04 1x36W FTL Recess Mounted Wall Washer, with electronic 8 Each - -
ballasts.
2.07 1 x 18/ 36W FTL Patti type luminaires with electronic 30 Each - -
ballasts.
3 CFL Downlighters.
3.01 2 x 13/18Watts Recessed CFL downlighter with special 50 Each - -
turbo low glare cross louver with electroninc ballasts and
the complete assembly.
3.06 1x11W Decorative Mirror top light fixtures for toilets of Each - -
Architect's choice with a basic rate of Rs.1500/- each.
4.01 1 Watt LED Lamps Circular recess mounted down light 14 Each - -
having 45 degree beam (Blue / White / Green colour)
with 4VA transformer
4.03 Recessed Eye Ball type 12V 50W Halogen light fixture Each - -
with moulded case copper wound transformer.
4.04 Recessed downlighter 4W LED light fixture with light Each
spreading
Philips Catlens and with
no. Accent power
LED supply
K2 4W unit.(picture light)
Lamps
4.06 Recessed Eye Ball type 5W LED light fixture with light Each
focusing lens and with power supply unit.
5 Fans.
5.01 Celing fans of following sizes with Down rods as per
false ceiling heights and with standard fitments like
condensor, hardware, rubber bushes, interconnecting
wires & terminals and other accessories. The installation
shall include providing necessary hooks and othe
fasteners at the true ceiling and required civil works.
6 Lighting automation.
6.02 Passive infrared (PIR) sensor - Non regulating type PIR 26 Each - -
sensor.
Make:Wipro
7 Misc. Lighting.
7.01 Removing, cleaning, servicing, painting and refixing of Nos. - -
the existing Ceiling fans, including existing long
supports. Refixing also inludes required hardwares,
rewiring, clamps, rubber bushes, canopies etc.
complete.
I EARTHING
1.01 GI earthing with 50mm dia. 3mt long GI pipe reducer, 2 Each - -
clamps, CI funnel,earthing leads etc. complete set
1.02 600x600x3.15 copper plate earthing with 19mm dia 3mt 6 Each - -
long GI pipe reducer, clamps, CI funnel,earthing leads
etc. complete set. Earth plate shall be connected to the
earthing lead via. 25x3mm copper strips.
- -
2 Busway installtion to the false ceiling level with required 22 Rmt - -
precise alignments including grip bolts, tools and
machineries.
BUSBAR TOTAL - -
K MISCELLANIOUS ITEMS
3 Misc. Items - -
3.01 Providing and fabrication of Steel items using angle / 80 Kg - -
channels. The rates shall include grip bolts, two coats of
primer and two coats synthetic enamel paint of
approved colour.
- -
3.02 3 Sets of asbuilt drawing and soft copy in CD with 1 LS - -
completion reports, History cards, Prevention maintance
schedule etc.
SUMMARY
Sl.No Amount
Item Description
. Supply Install
D FIBER BACKBONE - -
F TELECABLING - -
G MISCELLANIOUS ITEMS - -
SUB TOTAL - -
VAT@-------------% of total
1.2 Supply, termination, installation and testing of Cat-6 giga 998 Nos - -
speed information outlets for data, with choice of colors for
active & redundant ports and with flush mounted face
plates including cutout openings in the modular
workstations and tables and termmination. All the ports
shall have the display of printed port identification
numbers.
a 42 U Rack 5 Nos - -
b 45 U Rack Nos - -
5.5 19" Floor mounting closed Rack with front glass door,
openable side covers, AC distribution box, exhaust Fan
tray, castors/base frame and with required cable managers
& hardwares.
a 42 U Rack - 800W X 800D 4 Nos - -
b 42 U Rack - 800W X 1000D Nos - -
c 45 U Rack - 800W X 1000D Nos - -
6.0 TELECABLING
TELECABLING TOTAL - -
7 MISCELLANIOUS ITEMS
SUMMARY
LV SYSTEM
IV LV SYSTEM
B PA SYSTEM - -
D CCTV SYSTEM - -
E SPRINKLER SYSTEM - -
J MISCELLANIOUS ITEMS - -
SUB TOTAL - -
VAT@-------------% of total
LV SYSTEM TOTAL -
BILL OF QUANTITES
1.4 2 Loop additional interface cards for the existing Fire Nos - -
alarm Control panel for further expansion.
3 MISC. ITEMS
3.1 Response indicator for all detectors located above false 96 Nos - -
ceiling, below false flooring and detectors located in
closed cabins.
3.2 Panic bar of maximum of 1200mm wide (width to be 1 Nos - -
decided as per site conditions) with required alarm
section, magnetic contacts, integration with fire alarm
system.
4 CABLING:
4.1 2core x 1.5 sqmm copper conductor FRLS PVC insulated, 2548 Rmt - -
overall sheethed, GI wire armoured cables of 660V grade
clamped on true ceiling, walls using MS saddles at every
600mm. The cable shall be pulled through the PVC
sleeves to enable proper sealing and termination, when
required to be concealed on walls / floor.
4.2 2 runs of 1.5 sq.mm cross section FRLS PVC insulated Rmt - -
copper conductor wires pulled through PVC conduits. The
scope of work shall include providing and laying of FRLS
PVC conduits of minimum of 20mm dia and wall
thickness of 2mm. Including the conduit accessories like
bends, collars, junction boxes, fish wire, hardware etc.
complete.
5 FIRE EXTINGUISHERS
Stored pressure fire extinguishers of following types with
required brackets / mounts depending on the capacity.
The container shall be duly filled with the fire fighting
agent at the required pressure and conforming to IS
standrard.
B PA SYSTEM
1.1 Recess mounted 6 watts speakers with white grill, 110 80 Nos - -
volts modulated transformer with tappings to operate at
max. 2 watts capacity. (Make : Onkyo / Philips or Eq)
1.02 Wall mounted 6 watts 2 way speakers for staircase block 28 Nos
with 110 volts modulated transformer with tappings to
operate at max. 2 watts capacity.
2 CABLING
2.1 The speaker points wired with Tinned Copper conductor 1,620 Rmt - -
multistranded twin core 14/38 PVC insulated, overall
sheathed cable in PVC FRLS conduit of 2.0mm wall
thickness, with accessories as required.
3 EQUIPMENTS
3.5 100 to 10000 Hz, 2.2 mV/Pa, 600 ohms Hand Held Nos - -
Microphone with stand and 10 Mtr screened cable.
3.9 Wall / floor mount closed racks for the above equipment
with front glass door, vented rear door, side vented
panels, cable managers, exhaust fantray, power strips
with 6Amps sockets for all the equipment. The rack shall
also include required pedastals for
PA SYSTEM TOTAL - -
A EQUIPMENTS:
2 Readers:
2.1 Proximity card readers with read range of 15cm and with 10 Nos - -
visual & audible indications.
2.2 Proximity card readers with dual security (key pad - pin 2 Nos - -
prox) with read range of 15cm and with visual & audible
indications.
2.3 Finger scan Biometric readers with pinprox Key pad with 2 Nos - -
read range of 15cm and with visual & audible indications.
3 Exit push button switch with faceplate and GI back box. 6 Nos - -
4 Electro magnetic door lock suitable for single leaf doors. 10 Nos - -
B CABLING
1 Cables of tinned copper conductor, PVC insulated,
shielded & screened, unarmoured cables including
terminations of following categories pulled through PVC
FRLS conduits of dia. Not less than 20mm having 2.0mm
wall thickness with required conduit accessories,
hardwares etc.
1.01 8 Core x 1.0 Sq.mm twisted shielded cable Rmt - -
1.02 6 Core x 1.0 Sq.mm twisted shielded cable 595 Rmt - -
1.03 4 Core x 1.0 Sq.mm twisted shielded cable 655 Rmt - -
C MISCELLANIOUS
D CCTV SYSTEM
1 EQUIPMENTS
Supply, installation, testing and commissioning of
following CCTV equipments with required hardwares.
Each component shall be self reliant with all the
components built within. The installation shall include
cutting open false ceiling / civil works like wall cutting,
finishing etc.
1.01 1/3", 0.5 Lux, CCD color Camera with 3.6mm lens, 16 Nos - -
mounting brackets.
1.03 Digital Video Recorder with I/P & O/P operations and
Windows 2000 operating systems of following
configurations.
a 16Channel DVR with with 320GB hard disk capacity. 1 Nos - -
b 8 Channel DVR with with 320GB hard disk capacity. Nos - -
2 CABLING
2.1 Cables of following categories pulled through PVC FRLS
conduits of dia. Not less than 20mm having 2.0mm wall
thickness with required conduit accessories, hardwares
etc.
2.1.1 RG-59 coaxial unarmoured cable, including terminations 1,900 Rmt - -
on both ends with required connectors, plugging jacks
etc.
2.1.2 4C x 1 sqmm cables of tinned copper conductor, PVC 1,900 Rmt - -
insulated, shielded & screened, unarmoured cables
including terminations.
E SPRINKLER SYSTEM
14 2 runs of 1.5 sq.mm cross section FRLS PVC insulated 200 Rmt - -
copper conductor wires pulled through PVC conduits. The
scope of work shall include providing and laying of FRLS
PVC conduits of minimum of 20mm dia and wall
thickness of 2mm.
2 Transducers 16 Nos. - -
4 Stand Bracket 15 No - -
5 Supply and surface laying of 4 Core flexible cable in PVC 345 Mtrs - -
Conduit
3 Electro magnetic door lock suitable for single leaf doors. 2 Nos. - -
5 CABLING
4C X 14/38 shielded Cable in FRLS PVC conduits of 200 mts - -
minimum of 20mm dia and wall thickness of 2mm.
J MISCELLANIOUS ITEMS
MISCELLANIOUS ITEMS - -
SUMMARY
HVAC WORKS
Sl.N Item Description Amount
o. Supply
V HVAC WORKS
A AIR-CONDITIONING DX EQUIPMENTS -
B AIR DISTRIBUTION -
C INSULATIONS -
E DRAIN PIPING -
F AC UNIT INSTALLATIONS -
G PRECISION AIR-CONDITIONING -
I MISCELLANIOUS ITEMS -
SUB TOTAL -
VAT@-------------% of total
HVAC TOTAL -
BILL OF QUANTITES
A AIR-CONDITIONING DX EQUIPMENTS
1 DUCTING
Factory fabricated sheet metal ducting or using
lockformer machine complete made out of GSS sheets
with ductmate / angle iron flanges, sealants, gaskets,
GI metal cleats etc. The supply air collars, vanes,
splitters are also part of the ducting. Electro-
galvanized bolts, nuts & washers, Threaded GI
suspension rods, anchor grip bolts, Hi-tech or
equivalent supports for ducts in accordance with the
approved shop drawings. Painting of the ducts to black
color behind the grills shall be included.
C INSULATIONS
1 Acoustic lining for the ducts with following
specifications and as per approved drawings.
1.1 9mm thick armasound rubber insulation inside the 2950 Sft -
duct with required adhesives.
-
2 Thermal insulation of the ducts with following -
specifications and as per approved drawings.
2.1 9mm thick nitrile rubber insulation over the duct with 12100 Sft -
required adhesives.
2.2 Factory laminated fibreglass cladded with Al. foil with Sft -
required adhesive tapes of superior quality for the
tailend ducting.
-
3 Under deck insulation for the roof exposed to the -
sunlight with following specifications and as per
approved drawings.
3.1 13mm thick nitrile rubber insulation stuck below the Sft -
true ceiling with required adhesives.
3.2 Expanded polystyrene of 16Kg/ m3 density and 50 Sft -
mm thick stuck to the true ceiling with Bitumin and
held together with rawl plug and wire bracing in criss-
cross fashion.
-
4 Floor insulation for the complete surface area in contact -
with under floor discharge supply air below the false flooring,
with following specifications and as per approved drawings.
INSULATIONS TOTAL -
1 Diffusers:
Powder coated, extruded aluminium, removable centre
core type diffusers for supply / return air. All diffusers
should be of following neck sizes and 595x595 OTO
suitable for 600x600 false ceiling grid. Diffuser shall
be neatly finished and shall be exclusive of dents,
cracks, burs etc. Diffuser sides shall be finished with
tegular edge for grid ceilings. The supply air diffuser
shall be equipped with alluminium construction
opposed blade volume control dampers with adjusting
screws extended. The diffusers should be aligned to
the flase ceiling grid but not resting on it. It should be
attached / rigidly fixed to the pre insulated diffuser
box.
1.1 SADs - Outer to outer - 595mm x 595mm - neck sizes 116 Nos. -
ranging from 225mm to 450mm and with Aluminium
volume control damper.
1.7 450mm x 450mm insulated GI plenum box for each of 140 Nos. -
the supply air diffuser.
1.8 250mm dia. Twin Flap GI round butterfly dampers for 140 Nos. -
each of the supply air diffuser.
2 Grilles:
Continuous linear fixed bar extruded aluminium
powder coated supply / return air grilles of following
sizes normal flow 15° one way / two way deflection
with all sides flanged without dampers. Verticals shall
be in black color and as per approved samples.
3 VCDs:
GSS construction opposed blade volume control
dampers within ducts to be provided with suitable
links, levers and quadrants for manual control of
volume of air flow and for proper balancing of the air
distribution system.
3.1 Collar dampers. 10 Sft. -
3.2 Dampers for main ducts 98 Sft. -
E DRAIN PIPING
1 Blue Colour HDPE condensate drain piping of following
diameter for AC indoor units, complete with "U" trap
and fittings. The elbows from the AC unit drain point
to the floor trap / nearest toilets / plumbing shafts.
The pipe shall be covered with tubular vedoflex
insulation of right size. The termination in shafts
should not be left open and to be connected to nearest
waste water piping or taken down & terminated at
ground level to the waste water line.
F AC UNIT INSTALLATIONS
G PRECISION AIR-CONDITIONING
1 EQUIPMENTS
The Cabinet shall be using sandwich panels with
incombustible and steel sheet facing (Class 0, ISO
11822.2). The insulation shall be of mineral fiber
300kg/m3 density. The refrigeration compressor shall
be of scroll type , Clss IP54, the refrigerant shall be
R22 gas [R407 optional].
The fan assembly shall be of free-wheel type, single
inter, sheet steel backward curved blades, direct
driven by 3 Ph power supply, IP44 Electric Motor
installed on 3mm thick support plate with antivibrating
rubber isolators. The Direct expansion cooling coils &
chilled water coils are suitably mounted. The units
shall be of following configurations, including the
controller for to facilitate equal runtime, take over of
faulty machines among units etc.
VAVs TOTAL -
I MISCELLANIOUS ITEMS
MISCELLANIOUS ITEMS -
R MISCELLANEOUS WORKS
5 Artefacts/Plants 1 L.S.
Providing and placing of artificial plants, pots &
artifacts in the office premises as per the architect's
direction.( Approx value to be 50,000/- per lot )
I INTERIORS:
1 Wood Teak wood/Steam beech wood/Approved Equivalent
2 Vitrified tile Euro/Kajaria/Johnson /Approved Equivalent
3 Semi-vitrified tiles Euro/Kajaria/Johnson /Approved Equivalent
4 Gypsum Board India Gypsum Ltd/Lafarge/Approved Equivalent
5 Grid ceiling Armstrong/ Diaken / Jitex/Approved Equivalent
6 Plain Particle Board Duratuff / Novapan/Asis/Approved Equivalent
7 MDF Duratuff /Nuwud/Asis (Interior quality)/Approved
Equivalent
8 Veneer Timex/Uro /Jackson/Greenply/Approved Equivalent
9 Laminate Vir /National/Formica/Approved Equivalent
10 Flush Door Uniply / Atlanta /Approved Equivalent
11 Waterproof plywood Archid /Uniply / Kitply /Approved Equivalent
12 Commercial plywood / BB Archid /Uniply / Kitply /Approved Equivalent
13 Wood preservatives Wood guard / Termisil/Approved Equivalent
14 Door closers Dorma/Ozone/Godrej/Approved Equivalent
15 Floor spring Dorma/Ozone/Godrej/Approved Equivalent
16 Furniture Hardware EG/ Dorset/Approved Equivalent
17 Aluminium channel Hafele /Approved Equivalent
18 Melamine Coat Asian or Approved Equivalent
19 Paints Berger / Asian /Approved Equivalent
20 Texture Spectrum / Novatex /Approved Equivalent
21 French Polish Sheenlac / Light House /Approved Equivalent
22 Adhesive Fevicol SH / Jeevanjor / Araldite/Approved Equivalent
II ELECTRICAL WORKS
IV LV SYSTEMS
A FA SYSTEMS
1 FA Control Panel Cooper / Edward /Approved Equivalent
2 Smoke Detectors (all types) Cooper / Edward /Approved Equivalent
3 SC Isolator Cooper / Edward /Approved Equivalent
4 Control Relay Module Cooper / Edward /Approved Equivalent
5 Manual Call Point Cooper / Edward /Approved Equivalent
6 Sound/ Flashes Cooper / Edward /Approved Equivalent
7 Fire Extinguisher Usha Armour / Excellent Fire Services/Approved
Equivalent
B PA SYSTEMS
1 Speakers Bosch / Ahuja/Approved Equivalent
2 Amplifier Bosch / Ahuja/Approved Equivalent
3 CD Player/ Tuner Philips / Sony/Approved Equivalent
D CCTV SYSTEMS
1 Camera Samsung / GE /Approved Equivalent
2 Power Supply Unit Gallant /Approved Equivalent
3 DVR Samsung / GE /Approved Equivalent
4 Monitor LG / Samung /Approved Equivalent
E FM 200System
1 FM 200 UL approved Chemetron / Kidde / Greatlake /Approved Equivalent.
V HVAC WORKS