You are on page 1of 1

Coal mill trip accident

Indications:

 DCS alarm.
 Tripped coal mill motor current reaches to 0, the accident sound and light alarm, the furnace negative
pressure increases.
 The corresponding coal feeder gets tripped.
 Loss of fire detection
 The main steam pressure and temperature decrease.
 The negative pressure of furnace increases and fluctuates greatly.

Dealing with accident:

 If four or more coal mill systems are still in operation after one coal mill system trips, adjustment shall be
made carefully to increase the output of the other coal mills to ensure stable combustion.
 Put the standby coal mill into operation immediately, find out the tripping reason of the coal mill as soon
as possible, and restore the coal mill for standby.
 If three or less coal mill systems are in operation after one coal mill system trips, oil shall be put in
immediately to support combustion and standby coal mill shall be started.
 After the coal mill trips, the coal feeder shall be automatically stopped, otherwise, the coal feeder shall be
stopped manually immediately, the cold and hot air isolating valves, regulating valves, the outlet valves of
the coal mill shall be closed, the sealed air valves shall be closed, the fire steam shall be introduced, and
the outlet temperature of the coal mill shall be monitored to be no more than 70 ℃.
 Pay attention to the regulation of steam pressure and steam temperature. If the pressure drops too fast,
immediately reduce the load and maintain the pressure to prevent sudden drop of steam temperature and
forced shutdown. If the boiler is to be extinguished in the process of treatment, immediately manually stop
the boiler with MFT.
 When the tripped coal mill is started again, the coal mill must be purged and dumped.