You are on page 1of 1

TOUCH CALIBRATION FOR TECHNOTRANS PC

In order to fix the problem, we simply must enter into the config file
some coordinates that will work. The config file is called "touchConfig"
and you should check first the path to this file from the Linux
operating system. Mostlikely you will find this file in the path:
/var/ttapcs/      or    /var/tta_1/
How to enter new coordinates into "touchConfig" of the touchscreen, if
it is far out of calibration:
1. Start the system and run the normal program "damp.control"
2. close the damp.control program with "Alt" and "F4" and confirm with
yes.
3. right mouse-click ->  Editors  ->  choose "nedit"
4. File  ->  open  ->  and now you need to enter the appropriate path
from above
5. In the opened touchConfig file you should see the following:
Option "MaxX" "3626"
Option "MinX"  "518"
Option "MaxY" "3553"
Option "MinY" "583"
Please verify the values or if somewhat different, then correct as
above. Please write down the numbers that you are overwriting; just for
reference.
6. Safe and leave the touchConfig file and restart the system.
7. Now you should be able to do the normal touch-calibration

You might also like