1- Make sure that By-Pass valve and overboard valve are open. 2- Make sure engine mode selector is on normal mode. 3- Engage 24 V circuit breaker at bridge “24V distribution” panel. 4- Engage 220 V circuit breaker at “Nautical equipment” panel. 5- Engage 440 V circuit breaker at “Main switch board”. 6- Switch FIFI panel selector “System operation” from “Stand-By” to “On”. 7- Check operation for suction and discharge valves. 8- Reduce engine speed to 400 rpm, switch engine mode selector to “St.By”. 9- Open suction valve, wait until indication led stop flashing and valve open led is on. 10-Engage FIFI clutch, wait until indication led stop flashing, clutch led is on and ready for FIFI led is on. 11-Wait until water comes out of FIFI monitor. 12-Open discharge valve, wait until indication led stop flashing, valve open led is on and water jet increase. 13-Switch engine mode selector to “FIFI” mode. 14-Control direction and height of water using joy-stick. 15-Control water jet to spray using the selector beside joy-stick. 16-Water jet can be increased by closing overboard valve. 17-Only STBD side monitor has flow control reducer. FOAM system: 1- Open FOAM suction valve. 2- Open ejector valve placed on FIFI discharge line. 3- Use flow control valve to control the FOAM flow. Stopping the system: 1- Open overboard valve. 2- Switch engine mode selector to “St-By” mode. 3- Clutch out FIFI pump. 4- Close discharge valve. 5- Switch engine mode selector to “Normal” mode. 6- Close suction valve. 7- Switch FIFI panel selector “System operation” from “On” to “Stand-By”. 8- Open drain valves for the system. 9- Disengage all circuit breakers.