NEW 2-PIPE MINI ECOi LE SERIES FOR
LIGHT COMMERCIAL & RESIDENTIAL USE
NEW
COMPACT
DESIGN
2 .
NEW / MINI ECOi SYSTEMS
1 2 3
Efficiency energy control Space saving Flexible installation
Upgraded outdoor units deliver high efficiency Ideal for commercial locations with limited Reduced installation time thanks to compact
rating and reduced energy costs. space such as banks and shops. units and extra long piping without additional
Compact units integrate easily and discreetly refrigeration charge. High external static
into building design. pressure 35Pa and small chassis maximize
installation options.
. 3
EFFICIENCY ENERGY CONTROL
RELIABLE
QUALITY
4 .
NEW / MINI ECOi SYSTEMS
3 layers
Powerful heat exchanger. 3 layers of heat Panasonic twin Rotary Compressor. A New design fan. Fan braves have been
exchanger for all LE series. LE Series features large capacity inverter compressor has been redesigned to inhibit air resistence and to
the same heat exchange volume as adopted. This new compressor features wider increase efficiency. The larger fan increases
conventional model even though it is 15% and 0,1Hz step inverter control. air volume while maintaining low noise levels.
smaller in size.
5,00 5,19
3,00 3,31
18°C
2,00
-25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50
Cooling: Outside air temperature ˚C (DB). Heating: Outside air temperature ˚C ( WB).
1,00
0
4HP 5HP 6HP 8HP 10HP 4HP 5HP 6HP 8HP 10HP
Bluefin condenser: High durability outdoor unit (LE2 / LE1)
EER COP
The anti-corrosion Bluefin treatment of the heat exchanger provides
greater resistance against corrosion. All models are equipped with Bluefin
Maximum comfort with quiet operation mode condenser and treated with high corrosion resistance to rust and salty air
· Quiet operation mode reduces outdoor unit operating sound by 7dB(A) for long-lasting performance.
· 4-step set point is available
· Silent mode 1 maintains rated cooling capacity
* Timer setting of quiet operation mode is available in High-spec remote controller.
. 5
SPACE SAVING & FLEXIBLE
INSTALLATION INVISIBLE FROM
THE STREET
6 .
NEW / MINI ECOi SYSTEMS
SHORT
Compact design HEIGHT
Mini ECOi LE Series is a single unit 996mm
Perfect for installations with limited space and easy to hide within a
1.330mm
modern building. Flexible space-saving options compared to single split
1.500mm
system.
996mm
LE2 lower height of 996mm
New LE2 Series is 25% smaller in height than conventional model.
PREVIOUS 4 TO
980mm 6HP LE1
370mm
4 TO 6HP LE2 8 AND 10HP LE1
When unit is installed on a narrow balcony and exposed to the sun, the
barrier at the front side would restrict hot air from being discharged. Heat
accumulated in an enclosure can cause over-heating. This could
potentially result in damage or shorten the product’s life span. A high
external static pressure sends the air further away from the outdoor unit
and through the barrier. This provides better air circulation and
distribution.
And a high air pressure of 35Pa discharges the hot air a sufficient
Heat Accumulated When the pressure is Heat Discharged But with a high pressure
distance.
low, hot air will accumulate in the unit thus of 35Pa, hot air is sent further away
affecting its work performance and that of preventing overheating inside the outdoor
unit above it as well. unit enclosure.
NO
Long piping length for greater design flexibility Flexible & easy installation REFRIGERANT
CHARGE UP
LE1: Maximum total piping length: 300m · 50m piping length without refrigerant charge
TO 50M
LE2: Maximum total piping length: 180m · A 50m pipe length is sufficient for most residential
and small business buildings
LE1 or LE2
Height
difference
50m*
*40m if the outdoor
unit is below the
indoor unit. Level difference
between indoor
units 15m
R2 ROTARY
-10°C -20°C R22 R410A PROFESSIONAL
COMPRESSOR BLUEFIN COOLING MODE HEATING MODE AUTOMATIC RESTART R22 RENEWAL AC SMART CLOUD INTERNET CONTROL 5 YEARS
COMPRESSOR
WARRANTY
Optional
8 .
NEW / MINI ECOi SYSTEMS
Prepare to be blown away by Panasonic’s New Mini VRF system. The Mini
VRF compact system is the ideal solution for minimum outdoor space.
Panasonic extends the Mini VRF range by 8 and 10HP units.
Technical focus
· Piping flexibility with 150m maximum length
· High efficiency
· 15 indoor units connectable
· Quiet operation mode (one of the lowest in the market)
· High ambient temp performance
· High static pressure 35Pa
HP 8HP 10HP
Model U-8LE1E8* U-10LE1E8*
Voltage V 380 400 415 380 400 415
Power supply Phase Three Phase Three Phase
Frequency Hz 50 50
Cooling capacity kW 22,40 28,00
EER 1) W/W 3,80 3,11
Running current cooling A 9,60 9,15 8,80 14,70 14,00 13,50
Input power cooling kW 5,89 9,00
Heating capacity kW 25,00 28,00
COP 1) W/W 4,02 3,93
Running current heating A 10,20 9,65 9,30 11,60 11,10 10,70
Input power heating kW 6,22 7,13
Starting current A 1,00 1,00
Maximum current A 13,70 19,60
Maximum input power kW 9,16 13,10
Maximum number of connectable indoor units 15 2) 15 2)
External static pressure Pa 0 ~ 35 0 ~ 35
Air volume m³/min 150 160
Cooling dB(A) 60 63
Sound pressure Cooling (Silent 1 / 2 / 3) dB(A) 57 / 55 / 53 60 / 58 / 56
Heating dB(A) 64 65
Sound power Cooling / Heating dB 81 / 85 84 / 86
Dimensions / Net weight HxWxD mm / kg 1.500 x 980 x 370 / 132 1.500 x 980 x 370 / 133
Liquid pipe Inch (mm) 3/8 (9,52) 3) / 1/2 (12,70) 4) 3/8 (9,52) 3) / 1/2 (12,70) 4)
Piping connections
Gas pipe Inch (mm) 3/4 (19,05) 3) / 7/8 (22,22) 4) 7/8 (22,22) 3) / 1 (25,40) 4)
Maximum piping length range (total) m 7,5 ~ 150 (7,5 ~ 300) 7,5 ~ 150 (7,5 ~ 300)
Elevation difference (in/out) m 50 (Outdoor unit upper) / 40 (Outdoor unit lower) 50 (Outdoor unit upper) / 40 (Outdoor unit lower)
Refrigerant (R410A) kg / TCO2 Eq. 6,3 (24,0) / 13,1544 6,6 (24,0) / 13,7808
Maximum allowable indoor / outdoor capacity ratio % 50 ~ 130 50 ~ 130
Operating range Cooling / Heating Min ~ Max °C -10 ~ +46 / -20 ~ +18 -10 ~ +46 / -20 ~ +18
1) EER and COP classification is at 400 V in accordance with EU directive 2002/31/EC. 2) If the heating utilized, it is necessary to increase 1 size with respect to the main liquid pipe, depending on the combination of the indoor unit. 3) Under 90m for ultimate indoor unit.
4) Over 90m for ultimate indoor unit. If the longest piping equivalent length exceeds 90m, increase the sizes of the main tubes by 1 rank for gas and liquid pipes. * Tentative data.
BLUEFIN COOLING MODE HEATING MODE AUTOMATIC RESTART R22 RENEWAL AC SMART CLOUD INTERNET CONTROL 5 YEARS
COMPRESSOR
WARRANTY
Optional
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
Specifications subject to change without notice. For detailed information about ErP, please visit our websites www.aircon.panasonic.eu or www.ptc.panasonic.eu.
9
INDOOR UNITS RANGE
1,5kW 2,2kW 2,8kW 3,0kW 3,6kW 4,0kW 4,5kW
NEW U2 Type.
4 Way 90x90 Cassette
S-22MU2E5A S-28MU2E5A S-36MU2E5A S-45MU2E5A
T2 Type. Ceiling
S-36MT2E5A S-45MT2E5A
10 .
NEW / MINI ECOi SYSTEMS
S-56MY2E5A
S- 56ML1E5 S-73ML1E5
S-56MD1E5 S-73MD1E5
S-56MM1E5A
S-224ME2E5 S-280ME2E5
S-56MP1E5 S-71MP1E5
S-56MR1E5 S-71MR1E5
Frigro nv
Fax: +32(0)56 40 31 55
Tel.: +32(0)56 41 95 93
Meer weten over Panasonic? Bezoek www.heatingandcoolingsystems.be