You are on page 1of 4

STRUCTURAL DESIGN (TYPE B)

Building Elements As Per Submitted Design Remarks


General
Building Structure Type Frame Structure
No. of Storeys applied for permit (in Nos.) three storey
Number of storeys considered in structural
design (in Nos.) three storey
If Computer Aided Design (CAD) is used, please
state the name of the software package Etabs 2016
Number of storeys considered in the design Yes
provision for further extension (in Nos.) No
Total height (h) of structure with extension (in 8.53
m)
NBC 101-1994 MATERIALS SPECIFICATIONS
structural Aluminium
Brick Masonry
Materials to be used in structure (tick the Timber
listed materials that will be used in structure
element) Structural Steel
RCC ( Reinforcement Bar)
Stone Masonry
NBC 101-1994 Unit Weight of Materials
Specify the design unit weight of materials :
Steel (in kg/m3) 7850
Specify the design unit weight of materials :
RCC (in kg/m3) 2500
Specify the design unit eight of materials :
Brick Masonry (in kg/m3) 1900
NBC 101-1994 Unit Weight of Materials
For Residential Buildings
Occupancy Load (Uniformly Distibuted load in
KN/m2) for Bed rooms, ward, dressing rooms. 2
Occupancy Load (Uniformly Distibuted load in
KN/m2) for Kitchen. 2
Occupancy Load (Uniformly Distibuted load in
KN/m2) for X-ray rooms, operation rooms.
Occupancy Load (Uniformly Distibuted load in
KN/m2) for Corridors, Passage and Staircase. 3
Occupancy Load (Uniformly Distibuted load in
KN/m2) for Balconies. 3
NBC 101-1994 Unit Weight of Materials
Wind Zone 2
Basic wind speed (in m/s) 47
NBC 101-1994 Seismic Design of Buildings in Nepal
Seismic Coefficient Approach
Method adopted for earthquake resistant desig Response Spectrum Method
Method adopted for earthquake resistant desig
Others
Adopted Code for Seismic Design IS 1893
Type I (Hard)
Subsoil Category Type II (Medium)
Type III (Soft)
Seismic Weight (W) (in KN) 2282.81
Fundamental Time period of the building along
X (Tx) (in seconds) 0.374
Fundamental Time period of the building along
Y (Ty) (in seconds) 0.374
Basic Seismic Coefficient Along X ( C ) 0.08
Basic Seismic Coefficient Along Y( C ) 0.08
Seismic zoning factor (Z) 1
Imortance Factor (I) 1
Structural Performance
Design Horizontal factorCoefficient
Seismic (K) (if NBC used)
Along 1
X(Cd)
Design Horizontal Seismic Coefficient Along 0.08
Y(Cd) 0.08
Base Shear (Vb) for Seismic Coefficient Along X 205.45
Base Shear (Vb) for Seismic Coefficient Along Y 205.45
Base Shear Generated through dynamic
Analysis Along X ( if response spectrum
method used)
Base Shear Generated through dynamic
Analysis Along Y ( if response spectrum
method used)
Adopted Base Shear multiplication Factor
Along X (if response spectrum method used)
Adopted Base Shear multiplication Factor
Along Y (if response spectrum method used)
Base Shear after Scale Factor Along X 205.45
Base Shear after Scale Factor Along Y 205.45
Maximum Inter Sorey Drift 0.001009
Corresponding Storey height for Maximum
Inter-Strey Drift (h) 2.845
NBC 106-1994 Snow Load
Perennial
Snowfall type or condition Occasional
No snowfall
Elevation of construction site (in m)
Design Depth of snow (in cm)
Design Density of sno (in g/cm3)
NBC 107-1994 Provisional Recommendation on Fire Safety
Yes
Have you considered fire safety requirement?
No
NBC 108-1994 Site Consideration for Seismic Hazards
Whether Distance of construction site from Yes
toe/beginning of downward slope is within
50m? No
Whether Distance of construction site from Yes
river bank is within 50m? No
Yes
Availability of soil test report
Availability of soil test report
No
NBC 114-1994 Construction Safety
Are you sure that all safety measures will be Yes
fulfilled in the construction site as per this
code? No

safety hard hat


Materials to be used in structure (tick the safety goggles
listed materials that will be used in structure
element) safety boots
safety belts
first aid facility
Structural Data for Framed RCC Structure
NBC 110-1994 Plain and Reinforced Concrete
Concrete grade in structure M20
M25
M30
M35
Reinforcement Steel Grade Fe-415
Fe-500
Fe-550
Slab design
4 side continous
1 short side discontinous
1 long side discontinous
2 adjacent side continous
boundary condition of slab
2 long side continous
2 short side continous
1 short side continous
4 side discontinous
Effective Thickness of slab (d) (in mm) 108.00
Short span of Critical slab panel (L) (in mm) 4160.00
Calculated short span to effective depth ratio 38.5185185185185
(L/d)
Basic for theratio
(L/d) corresponding slab 23.00
Required modification factor for tension 1.673
reinforcement
Required Tension reinforcement(Ast) 0.207
Percentage (%) for short span bottom
reinforcement
Provided Tension reinforcement(Ast) 0.67
Percentage (%) for short span bottom
reinforcement
Actual Modification factor for tension 2
reinforcement
Check for Critical beam
Effective depth of beam (d) (in mm) 315
Critical span (L) (in mm) 5105
Cantilever
Simply supported
Support condition
One side continous
Both side continous
Basic (L/d) ratio 23
Calculated critical span to effective depth ratio 16.2063492063492
(L/d) for corresponding slab
Check for Critical Column
Critical Column height 2.4
Minimum size of column (mm x mm) 305 x 305
Yes
Short column effect considered or not
No
Minimum area of longitudinal reinforcement 1.35
provided(%)

Design Philosophy Limit state method


Load Combinations
1:DL 1.5
1:LL 1.5
1:EQ
2:DL 1.2
2:LL 1.2
2:EQ 1.2
3:DL 0.9
3:LL
3:EQ 1.5
4:DL 1.5
4:LL
4:EQ 1.5

Whether sample design calculations of Yes


foundations, columns, beams and slabs are
submitted No
Isolated
Combined
Type of Foundations Raft
PILE
Strap
Depth of foundation from ground level to the
bottom of footing (in mm)
1524