You are on page 1of 11

Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Base material Installation


No stand-off Installation.
Uncracked Concrete
Thickness of base material 150 mm Anchor plate
Strength Class C40/50 Assumed rigid plate
fck,cube 50 N/mm2 Thickness of the plate 8 mm
Plate shape Custom geometry

Plate vertex Anchors Position

Vertex x y Anchor x y Slotted -x Slotted -y


1 -120.0 -107.0 1 -55.0 -3.0
2 -120.0 107.0 2 55.0 -3.0
3 120.0 107.0 3 -55.0 -78.0
4 120.0 -107.0 4 55.0 -78.0

= Slotted

Profile
No Profile has been applied

Selected Products
Anchor (name) ZJE01 - Wedge anchor
Approval ETA 13/1012
Size
Article code ZJE0110090

- Diameter 10, standard embedment depth

TADS - Tecfi Anchor Design Software


25/11/2020 Page: 1 / 11
v. 4.0.1.402 - Database 85.6.2230112240
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Anchor data
d Anchor/thread diameter: 10.0 mm tfix Thickness of fixture: 8.0 mm
dnom Outside diameter of anchor: 10.0 mm SW Spanner: 17.0 mm
d0 Drill hole diameter: 10.0 mm Tinst Max setting torque 35.0 Nm
h1 Depth of drilled hole: 75.0 mm
hnom Setting depth: 66.5 mm
hef Effective anchorage depth: 55.0 mm
df Diameter of clearance hole in fixture: 12.0 mm

Wedge anchor in carbon steel, with nut and washer, zinc plated, ETA-CE Opt.7 certified

TADS - Tecfi Anchor Design Software


25/11/2020 Page: 2 / 11
v. 4.0.1.402 - Database 85.6.2230112240
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Input Data
Tension Bending Reinforcement
NSd,Z 0.00 kN MSd,X -1.34 kN·m Diameter 11 mm
Shear MSd,Y 0.00 kN·m Distance rebars 200 mm
VSd,X 0.00 kN Torsion Distance stirrups 200 mm
VSd,Y 1.56 kN MSd,Z 0.00 kN·m Edge reinforcement No
Edges
CXp ∞ mm
CXn ∞ mm
CYp 120.00 mm
CYn ∞ mm

TADS - Tecfi Anchor Design Software


25/11/2020 Page: 3 / 11
v. 4.0.1.402 - Database 85.6.2230112240
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Calculated design loads on anchor(s)

Tension force Shear force Shear force (x) Shear force (y)
Anchor
[kN] [kN] [kN] [kN]
1 1.50 0.39 0.00 0.39
2 1.50 0.39 0.00 0.39
3 3.02 0.39 0.00 0.39
4 3.02 0.39 0.00 0.39

Resultant tension force: 9.05 [kN]


Resultant compression force: 9.05 [kN]
Resultant shear force: 1.56 [kN]

Calculation of Utilizations according to: ETAG 001, Annex C - Method A


(β- is the ratio between design load and design resistance)

Calculation of Utilisations - Tension loads

Tension - Steel Failure

NRk,s γM,s NRd,s NSd βN,s


Anchor
[kN] [-] [kN] [kN] [%]

25.60 1.40 18.29 1 1.50 8.2%

2 1.50 8.2%

3 3.02 16.5%

4 3.02 16.5%

TADS - Tecfi Anchor Design Software


25/11/2020 Page: 4 / 11
v. 4.0.1.402 - Database 85.6.2230112240
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Tension - Pull Out Failure

NRk,p γM,p ψc NRd,p NSd βn,p


Anchor
[kN] [-] [-] [kN] [kN] [%]
16.00 1.8 1.41 12.53
1 1.50 12.0%

2 1.50 12.0%

3 3.02 24.1%

4 3.02 24.1%

Tension - Concrete Cone Failure


NRk,c=N0Rk,c · ψA,N · ψs,N · ψre,N · ψec,N

hef scr,N ccr,N fck,cube γMc


[mm] [mm] [mm] [N/mm²] [-]
55 165 83 50 1.8

The anchors are divided into 1 group

Verification performed with three or more edges cmax < ccr

Group N0Rk,c Ac,N A0c,N hef scr,N ccr,N c-x c+x c-y c+y
Anchor
No. [kN] [mm²] [mm²] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
[1, 2, 3,
1 29.13 66,000 27,225 55 165 82 6,000 6,000 6,000 120
4]

Group ψs,N ψre,N eN,x eN,y ψec,N NRk,c NRd,c Nsd βN,c
Anchor
No. [-] [-] [mm] [mm] [-] [kN] [kN] [kN] [%]

1 [1, 2, 3, 4] 1.000 1.000 0.0 12.6 0.867 61.24 34.02 9.05 26.6%

Tension - Splitting Failure


NRk,sp=N0Rk,c · ψA,sp · ψs,sp · ψre,sp · ψec,sp · ψh,sp

Thickness of base material = 150.0 mm Required minimum thickness = 110.0 mm

hef fck,cube ψc hmin scr,sp ccr,sp γM,sp


[mm] [N/mm2] [-] [mm] [mm] [mm] [-]
55 50 1.410 110 220 110 1.8
The anchors are divided into 1 group

Group N0Rk,sp hef Ac,sp A0c,sp scr,sp ccr,sp c-x c+x c-y c+y
Anchor
No. [kN] [mm] [mm2] [mm2] [mm] [mm] [mm] [mm] [mm] [mm]

TADS - Tecfi Anchor Design Software


25/11/2020 Page: 5 / 11
v. 4.0.1.402 - Database 85.6.2230112240
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

1 [1, 2, 3, 4] 29.13 55 97,350 48,400 220 110 6,000 6,000 6,000 120

Group ψs,sp ψre,sp eNx eNy ψec,sp ψh,sp NRk,sp NRd,sp NSd βN,sp
Anchor
No. [-] [mm] [mm] [mm] [-] [-] [kN] [kN] [kN] [%]
[1, 2, 3,
1 1.000 1.000 0.0 12.6 0.897 1.230 64.63 35.905 9.05 25.2%
4]

TADS - Tecfi Anchor Design Software


25/11/2020 Page: 6 / 11
v. 4.0.1.402 - Database 85.6.2230112240
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Shear - Steel Failure Without Lever Arm

VRk,s γMs VRd,s


[kN] [-] [kN]

14.70 1.25 11.76

1 2 3 4

Vsd [kN] 0.39 0.39 0.39 0.39

βV,s [ % ] 3.3% 3.3% 3.3% 3.3%

Shear - Steel Failure With Lever Arm

No lever arm has been applied

Shear - Pryout Failure(NRk,c)


NRk,c=N0Rk,c · ψA,N · ψs,N · ψre,N · ψec,V,cp

VRk,cp=k · NRk,c

hef scr,N ccr,N fck,cube k γMc


[mm] [mm] [mm] [N/mm²] [-] [-]
55 165 83 50 1.0 1.5

The anchors are divided into 1 group

Group N0Rk,c Ac,N A0c,N ψs,N ψre,N c-x c+x c-y c+y
Anchor
No. [kN] [mm ] 2
[mm2] [-] [-] [mm] [mm] [mm] [mm]

1 [1, 2, 3, 4] 29.13 66,000 27,225 1.000 1.000 6,000 6,000 6,000 195

Group eN,x eN,y ψec,N NRk,c VRk,cp VRd,cp VSd βV,cp


Anchor
No. [mm] [mm] [-] [kN] [kN] [kN] [kN] [%]

1 [1, 2, 3, 4] 0.0 0.0 1.000 70.62 70.62 47.08 1.56 3.3%

TADS - Tecfi Anchor Design Software


25/11/2020 Page: 7 / 11
v. 4.0.1.402 - Database 85.6.2230112240
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Shear - Concrete Edge Failure


VRk,c=V0Rk,c · ψA,V · ψs,V · ψh,V · ψα,V · ψec,V · ψre,V

hef fck,cube d γVrkc


[mm] [N/mm²] [-] [-]
55 50 10 1.5

Edge"Yp"
Case: [1, 2]
Shear force[kN]
Anchor Q Qx Qy
1 0.78 0.00 0.78
2 0.78 0.00 0.78
3 0.00 0.00 0.00
4 0.00 0.00 0.00

Group c1 c2min V0Rk,c Ac,V A0c,V ψs,V ψh,V


Anchor Failure line Edge
No. [mm] [mm] [kN] [mm²] [mm²] [-] [-]

1 [1, 2] [1, 2] Yp 120 6,000 33.27 70,500 64,800 1.000 1.095

TADS - Tecfi Anchor Design Software


25/11/2020 Page: 8 / 11
v. 4.0.1.402 - Database 85.6.2230112240
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

Group ψα,V ev ψec,V ψre,V VRk,c VRd,c Vsd βV,c k1


Anchor
No. [-] [mm] [-] [-] [kN] [kN] [kN] [%] [-]

1 [1, 2] 1.000 0 1.000 1.000 39.65 26.43 1.56 5.9% 2.40

Combined tension and shear

Anchor Tension (βN) Shear (βV) Condition Utilisation Status

Steel 1 8.2% 3.3% β = β2N + β2V 2.8%

Concrete 1 26.6% 5.9% β = (β1.5N + β1.5V) 15.2%

TADS - Tecfi Anchor Design Software


25/11/2020 Page: 9 / 11
v. 4.0.1.402 - Database 85.6.2230112240
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge
Anchor

βN,s βN,p βN,comb βN,c βN,sp βV,s βV,sla βV,cp βV,c βN,s,max βV,s.max βN,c,max, βV,c,max,E βcombi,c,E βcombi,S,E
E

1 8.2% 12.0% 0.0% 26.6% 25.2% 3.3% 0.0% 3.3% 5.9% 8.2% 3.3% 26.6% 5.9% 15.2% 0.8%

2 8.2% 12.0% 0.0% 26.6% 25.2% 3.3% 0.0% 3.3% 5.9% 8.2% 3.3% 26.6% 5.9% 15.2% 0.8%

3 16.5% 24.1% 0.0% 26.6% 25.2% 3.3% 0.0% 3.3% 0.0% 16.5% 3.3% 26.6% 3.3% 14.3% 2.8%

4 16.5% 24.1% 0.0% 26.6% 25.2% 3.3% 0.0% 3.3% 0.0% 16.5% 3.3% 26.6% 3.3% 14.3% 2.8%

βN,s,max = βN,s
βV,s,max = max ( βV,s , βV,sla )

βN,c,max,E = max ( βN,p , βN,c , βN,sp , βN,comb )


βV,c,max,E = max ( βV,cp , βV,c )
βcombi,s,E = β2N,s + β2V,s
βcombi,c,E = min[ ( β1.5N,c,max,E + β1.5V,c,max,E), ( βN,c,max,E + βV,c,max,E ) / 1.2 ]

With consideration of related anchors and separation of steel and concrete failure

RESULT
Ok. The product meets the design criteria

REMARKS
The verification of anchor design cases covered by ETAG 001 or TR29 is performed according to the selected Guideline. The
verification of anchor design cases non-covered by guidelines is based on the selected Guideline. Further information can be
found inside ACP Design Guides. The loads acting on anchors are evaluated according to the theory of elasticity, assuming
that the anchor plate does not deform under the design actions. To ensure the validity of this assumption the anchor plate
shall be sufficient stiff. The user must verify this condition, since the base plate stiffness is not automatically calculated by the
software. The transfer of loads from anchors into base material must be verified in accordance with ETAG 001 Annex C or
TR29 Section 7. The design method is valid only for clearance hole in the fixture with a diameter not larger than the values
given in ETAG 001 Annex C or TR29 Table 4.1.

IMPORTANT NOTICE
The data input to this software, and the relative results, must be checked by the user under the responsibility of an engineer
experienced in anchorages and concrete work. This is to ensure there are no errors and all data is complete and accurate and
complies with all rules and regulations for the actual conditions and application.
The data contained in this software relates only to the product illustrated therein and is based on principles, formulas and
safety regulations according to the existing guidelines for anchorages into concrete, together with the knowledge of the
manufacturer.
The user must comply with these principles. The user is solely responsible for the data entered into the program and any
errors or omissions are the responsibility of the user. The user must ensure that the most current version of the program is

TADS - Tecfi Anchor Design Software


25/11/2020 Page: 10 / 11
v. 4.0.1.402 - Database 85.6.2230112240
Project

Reference code
Design office
Person in charge
Construction Office
Person in charge

installed by way of the auto-updating function offered by the manufacturer.


The user must update the program when instructed to do so.
The aim of the program is to act as a calculation aid and to assist in complying with current regulations and guidelines,
without any guarantee of suitability for any specific application.

TADS - Tecfi Anchor Design Software