You are on page 1of 7

Project Kempniski AL Madina

Bracket Curtain wall


Reference code SCH-CAL-KH-200622-CW04-R0
Design office
Person in charge
Construction Office
Person in charge

Base material Installation


Stand-off with grouting 10 mm
Cracked Concrete
Rotational Restraint 2.0
Thickness of base material 500 mm
Strength Class C25/30
fck,cube 30 N/mm2 Anchor plate
Assumed rigid plate
Thickness of the plate 8 mm
Plate shape Rectangle
Side length 290 X 75 mm

Plate vertex Anchors Position

Vertex x y Anchor x y Slotted -x Slotted -y


1 -145.0 -37.5 1 -50.0 0.0
2 -145.0 37.5 2 50.0 0.0
3 145.0 37.5
= Slotted
4 145.0 -37.5

Profile
Selected Profile No Profile has been applied
Eccentricity X: 0.0 mm
Y: 0.0 mm

Selected Products
Anchor (name) MTP anchor
Approval ETA 12/0397
Size M10 x 105
Article code AP10105

-
-

Anclajes / Anchors / Chevilles / Dübel /


02/10/2021 Page: 1 / 7
v. 4.2.14.352 - Database 1354.9.2884112611
Project Kempniski AL Madina
Bracket Curtain wall
Reference code SCH-CAL-KH-200622-CW04-R0
Design office
Person in charge
Construction Office
Person in charge

Anchor data
d Anchor/thread diameter: 10.0 mm tfix Thickness of fixture: 8.0 mm
dnom Outside diameter of anchor: 10.0 mm SW Spanner: 17.0 mm
d0 Drill hole diameter: 10.0 mm Tinst Max setting torque 40.0 Nm
h1 Depth of drilled hole: 75.0 mm
hnom Setting depth: 68.0 mm
hef Effective anchorage depth: 60.0 mm
df Diameter of clearance hole in fixture: 12.0 mm

PRODUCT:
MTP anchor in zinc plated.

CALCULATION METHOD:
This calculation method is based in specific values exclusively for MTP. Any modifications made --this being change of product brand
or changes in physical conditions of design-- require recalculation of the design

ANCHOR PLATE:
The design program assumes, in accordance with the design code, that the anchor plate does not deform as a result of applied
actions. Thus, in accordance with the design code, the anchor plate shall be sufficiently stiff and its design should be carried out
according to standards for steel structure ensuring elastic behavior.

INSTALLATION:
All conditions of the European Technical Assessment (ETA) and Index technical publications shall be complied with in all details.

ADDITIONAL PROOFS:
With regard to design of anchorages one shall to be aware of the additional proofs for ensuring the characteristics resistance of the
concrete member (structural component) described in the design code.

Anclajes / Anchors / Chevilles / Dübel /


02/10/2021 Page: 2 / 7
v. 4.2.14.352 - Database 1354.9.2884112611
Project Kempniski AL Madina
Bracket Curtain wall
Reference code SCH-CAL-KH-200622-CW04-R0
Design office
Person in charge
Construction Office
Person in charge

Input Data
Tension Bending Reinforcement
NSd,Z 5.40 kN MSd,X 0.00 kN·m Diameter 11 mm
Shear MSd,Y 0.20 kN·m Distance rebars 200 mm
VSd,X 2.13 kN Torsion Distance stirrups 200 mm
VSd,Y 0.00 kN MSd,Z 0.00 kN·m Edge reinforcement No

Edges
CXp ∞ mm
CXn ∞ mm
CYp ∞ mm
CYn ∞ mm

Design standard
ETAG

Anclajes / Anchors / Chevilles / Dübel /


02/10/2021 Page: 3 / 7
v. 4.2.14.352 - Database 1354.9.2884112611
Project Kempniski AL Madina
Bracket Curtain wall
Reference code SCH-CAL-KH-200622-CW04-R0
Design office
Person in charge
Construction Office
Person in charge

Calculated design loads on anchor(s)

Tension force Shear force Shear force (x) Shear force (y)
Anchor
[kN] [kN] [kN] [kN]
1 4.17 1.06 1.06 0.00
2 1.83 1.06 1.06 0.00

Resultant tension force: 6.00 [kN]


Resultant compression force: 0.60 [kN]
Resultant shear force: 2.13 [kN]

Calculation of Utilizations according to: ETAG 001, Annex C - Method A


(β- is the ratio between design load and design resistance)

Calculation of Utilisations - Tension loads

Tension - Steel Failure

NRk,s γM,s NRd,s NSd βN,s


Anchor
[kN] [-] [kN] [kN] [%]

31.40 1.50 20.93 1 4.17 19.9%

2 1.83 8.8%

Tension - Pull Out Failure

NRk,p γM,p ψc NRd,p NSd βn,p


Anchor
[kN] [-] [-] [kN] [kN] [%]
9.00 1.5 1.08 6.48
1 4.17 64.3%

2 1.83 28.3%

Tension - Concrete Cone Failure


NRk,c=N0Rk,c · ψA,N · ψs,N · ψre,N · ψec,N · ψm,N

hef scr,N ccr,N fck,cube γMc


[mm] [mm] [mm] [N/mm²] [-]
60 180 90 30 1.5

The anchors are divided into 1 group

Group N0Rk,c Ac,N A0c,N hef scr,N ccr,N c-x c+x c-y c+y
Anchor
No. [kN] [mm²] [mm²] [mm] [mm] [mm] [mm] [mm] [mm] [mm]

Anclajes / Anchors / Chevilles / Dübel /


02/10/2021 Page: 4 / 7
v. 4.2.14.352 - Database 1354.9.2884112611
Project Kempniski AL Madina
Bracket Curtain wall
Reference code SCH-CAL-KH-200622-CW04-R0
Design office
Person in charge
Construction Office
Person in charge

1 [1, 2] 18.33 50,400 32,400 60 180 90 6,000 6,000 6,000 6,000

Group ψs,N ψre,N eN,x eN,y ψec,N NRk,c NRd,c Nsd βN,c
Anchor
No. [-] [-] [mm] [mm] [-] [kN] [kN] [kN] [%]

1 [1, 2] 1.000 1.000 19.5 0.0 0.822 23.44 15.63 6.00 38.4%

Tension - Splitting Failure

As the calculation is performed for cracked concrete, no proof for splitting failure is required.

Calculation of Utilisations - Shear loads


Shear - Steel Failure Without Lever Arm

V0Rk,s VRk,s γMs VRd,s


[kN] [kN] [-] [kN]

17.40 17.40 1.25 13.92

1 2

Vsd [kN] 1.06 1.06

βV,s [ % ] 7.7% 7.7%

VRk,s calculated acc. EN-1992-4: Eq.7.35

Shear - Steel Failure With Lever Arm

Anclajes / Anchors / Chevilles / Dübel /


02/10/2021 Page: 5 / 7
v. 4.2.14.352 - Database 1354.9.2884112611
Project Kempniski AL Madina
Bracket Curtain wall
Reference code SCH-CAL-KH-200622-CW04-R0
Design office
Person in charge
Construction Office
Person in charge

l αm M0R,ks
[ mm ] [-] [ Nm ]

19.00 2.00 44.80

1 2

VR,ks [kN] 3.78 4.30

VRd,s [kN] 3.02 3.44

Vsd [kN] 1.06 1.06

βV,sla [ % ] 35.2% 30.9%

Shear - Pryout Failure(NRk,c)


NRk,c=N0Rk,c · ψA,N · ψs,N · ψre,N · ψec,V,cp

VRk,cp=k · NRk,c

hef scr,N ccr,N fck,cube k γMc


[mm] [mm] [mm] [N/mm²] [-] [-]
60 180 90 30 2.0 1.5

The anchors are divided into 1 group

Group N0Rk,c Ac,N A0c,N ψs,N ψre,N c-x c+x c-y c+y
Anchor
No. [kN] [mm2] [mm2] [-] [-] [mm] [mm] [mm] [mm]

1 [1, 2] 18.33 50,400 32,400 1.000 1.000 6,000 6,000 6,000 6,000

Group eN,x eN,y ψec,N NRk,c VRk,cp VRd,cp VSd βV,cp


Anchor
No. [mm] [mm] [-] [kN] [kN] [kN] [kN] [%]

1 [1, 2] 0.0 0.0 1.000 28.51 57.02 38.01 2.13 5.6%

Combined tension and shear

Anchor Tension (βN) Shear (βV) Condition Utilisation Status

Steel 1 19.9% 35.2% β = β2N + β2V 16.4%

Concrete 1 64.3% 5.6% β = (β1.5N + β1.5V) 52.9%

Anclajes / Anchors / Chevilles / Dübel /


02/10/2021 Page: 6 / 7
v. 4.2.14.352 - Database 1354.9.2884112611
Project Kempniski AL Madina
Bracket Curtain wall
Reference code SCH-CAL-KH-200622-CW04-R0
Design office
Person in charge
Construction Office
Person in charge
Anchor

βN,s βN,p βN,comb βN,c βN,sp βV,s βV,sla βV,cp βV,c βN,s,max βV,s.max βN,c,max, βV,c,max,E βcombi,c,E βcombi,S,E
E

1 19.9% 64.3% 0.0% 38.4% 0.0% 7.7% 35.2% 5.6% 0.0% 19.9% 35.2% 64.3% 5.6% 52.9% 16.4%

2 8.8% 28.3% 0.0% 38.4% 0.0% 7.7% 30.9% 5.6% 0.0% 8.8% 30.9% 38.4% 5.6% 25.1% 10.3%

βN,s,max = βN,s
βV,s,max = max ( βV,s , βV,sla )

βN,c,max,E = max ( βN,p , βN,c , βN,sp , βN,comb )


βV,c,max,E = max ( βV,cp , βV,c )
βcombi,s,E = β2N,s + β2V,s
βcombi,c,E = min[ ( β1.5N,c,max,E + β1.5V,c,max,E), ( βN,c,max,E + βV,c,max,E ) / 1.2 ]

With consideration of related anchors and separation of steel and concrete failure

RESULT
Ok. The product meets the design criteria

REMARKS
The verification of anchor design cases covered by ETAG 001 or TR29 is performed according to the selected Guideline. The
verification of anchor design cases non-covered by guidelines is based on the selected Guideline. Further information can be
found inside ACP Design Guides. The loads acting on anchors are evaluated according to the theory of elasticity, assuming
that the anchor plate does not deform under the design actions. To ensure the validity of this assumption the anchor plate
shall be sufficient stiff. The user must verify this condition, since the base plate stiffness is not automatically calculated by the
software. The transfer of loads from anchors into base material must be verified in accordance with ETAG 001 Annex C or
TR29 Section 7. The design method is valid only for clearance hole in the fixture with a diameter not larger than the values
given in ETAG 001 Annex C or TR29 Table 4.1.

IMPORTANT NOTICE
The data input to this software, and the relative results, must be checked by the user under the responsibility of an engineer
experienced in anchorages and concrete work. This is to ensure there are no errors and all data is complete and accurate and
complies with all rules and regulations for the actual conditions and application.
The data contained in this software relates only to the product illustrated therein and is based on principles, formulas and
safety regulations according to the existing guidelines for anchorages into concrete, together with the knowledge of the
manufacturer.
The user must comply with these principles. The user is solely responsible for the data entered into the program and any
errors or omissions are the responsibility of the user. The user must ensure that the most current version of the program is
installed by way of the auto-updating function offered by the manufacturer.
The user must update the program when instructed to do so.
The aim of the program is to act as a calculation aid and to assist in complying with current regulations and guidelines,
without any guarantee of suitability for any specific application.

Anclajes / Anchors / Chevilles / Dübel /


02/10/2021 Page: 7 / 7
v. 4.2.14.352 - Database 1354.9.2884112611