Selected Profile No Profile has been applied
Eccentricity X: 0.0 mm
Y: 0.0 mm
Selected Products
Anchor (name) MTP anchor
Approval ETA 12/0397
Size M10 x 105
Article code AP10105
-
-
Anchor data
d Anchor/thread diameter: 10.0 mm tfix Thickness of fixture: 8.0 mm
dnom Outside diameter of anchor: 10.0 mm SW Spanner: 17.0 mm
d0 Drill hole diameter: 10.0 mm Tinst Max setting torque 40.0 Nm
h1 Depth of drilled hole: 75.0 mm
hnom Setting depth: 68.0 mm
hef Effective anchorage depth: 60.0 mm
df Diameter of clearance hole in fixture: 12.0 mm
PRODUCT:
MTP anchor in zinc plated.
CALCULATION METHOD:
This calculation method is based in specific values exclusively for MTP. Any modifications made --this being change of product brand
or changes in physical conditions of design-- require recalculation of the design
ANCHOR PLATE:
The design program assumes, in accordance with the design code, that the anchor plate does not deform as a result of applied
actions. Thus, in accordance with the design code, the anchor plate shall be sufficiently stiff and its design should be carried out
according to standards for steel structure ensuring elastic behavior.
INSTALLATION:
All conditions of the European Technical Assessment (ETA) and Index technical publications shall be complied with in all details.
ADDITIONAL PROOFS:
With regard to design of anchorages one shall to be aware of the additional proofs for ensuring the characteristics resistance of the
concrete member (structural component) described in the design code.
Input Data
Tension Bending Reinforcement
NSd,Z 5.40 kN MSd,X 0.00 kN·m Diameter 11 mm
Shear MSd,Y 0.20 kN·m Distance rebars 200 mm
VSd,X 2.13 kN Torsion Distance stirrups 200 mm
VSd,Y 0.00 kN MSd,Z 0.00 kN·m Edge reinforcement No
Edges
CXp ∞ mm
CXn ∞ mm
CYp ∞ mm
CYn ∞ mm
Design standard
ETAG
Tension force Shear force Shear force (x) Shear force (y)
Anchor
[kN] [kN] [kN] [kN]
1 4.17 1.06 1.06 0.00
2 1.83 1.06 1.06 0.00
2 1.83 8.8%
2 1.83 28.3%
Group N0Rk,c Ac,N A0c,N hef scr,N ccr,N c-x c+x c-y c+y
Anchor
No. [kN] [mm²] [mm²] [mm] [mm] [mm] [mm] [mm] [mm] [mm]
Group ψs,N ψre,N eN,x eN,y ψec,N NRk,c NRd,c Nsd βN,c
Anchor
No. [-] [-] [mm] [mm] [-] [kN] [kN] [kN] [%]
1 [1, 2] 1.000 1.000 19.5 0.0 0.822 23.44 15.63 6.00 38.4%
As the calculation is performed for cracked concrete, no proof for splitting failure is required.
1 2
l αm M0R,ks
[ mm ] [-] [ Nm ]
1 2
VRk,cp=k · NRk,c
Group N0Rk,c Ac,N A0c,N ψs,N ψre,N c-x c+x c-y c+y
Anchor
No. [kN] [mm2] [mm2] [-] [-] [mm] [mm] [mm] [mm]
1 [1, 2] 18.33 50,400 32,400 1.000 1.000 6,000 6,000 6,000 6,000
βN,s βN,p βN,comb βN,c βN,sp βV,s βV,sla βV,cp βV,c βN,s,max βV,s.max βN,c,max, βV,c,max,E βcombi,c,E βcombi,S,E
E
1 19.9% 64.3% 0.0% 38.4% 0.0% 7.7% 35.2% 5.6% 0.0% 19.9% 35.2% 64.3% 5.6% 52.9% 16.4%
2 8.8% 28.3% 0.0% 38.4% 0.0% 7.7% 30.9% 5.6% 0.0% 8.8% 30.9% 38.4% 5.6% 25.1% 10.3%
βN,s,max = βN,s
βV,s,max = max ( βV,s , βV,sla )
With consideration of related anchors and separation of steel and concrete failure
RESULT
Ok. The product meets the design criteria
REMARKS
The verification of anchor design cases covered by ETAG 001 or TR29 is performed according to the selected Guideline. The
verification of anchor design cases non-covered by guidelines is based on the selected Guideline. Further information can be
found inside ACP Design Guides. The loads acting on anchors are evaluated according to the theory of elasticity, assuming
that the anchor plate does not deform under the design actions. To ensure the validity of this assumption the anchor plate
shall be sufficient stiff. The user must verify this condition, since the base plate stiffness is not automatically calculated by the
software. The transfer of loads from anchors into base material must be verified in accordance with ETAG 001 Annex C or
TR29 Section 7. The design method is valid only for clearance hole in the fixture with a diameter not larger than the values
given in ETAG 001 Annex C or TR29 Table 4.1.
IMPORTANT NOTICE
The data input to this software, and the relative results, must be checked by the user under the responsibility of an engineer
experienced in anchorages and concrete work. This is to ensure there are no errors and all data is complete and accurate and
complies with all rules and regulations for the actual conditions and application.
The data contained in this software relates only to the product illustrated therein and is based on principles, formulas and
safety regulations according to the existing guidelines for anchorages into concrete, together with the knowledge of the
manufacturer.
The user must comply with these principles. The user is solely responsible for the data entered into the program and any
errors or omissions are the responsibility of the user. The user must ensure that the most current version of the program is
installed by way of the auto-updating function offered by the manufacturer.
The user must update the program when instructed to do so.
The aim of the program is to act as a calculation aid and to assist in complying with current regulations and guidelines,
without any guarantee of suitability for any specific application.