Professional Documents
Culture Documents
DESIGN LOADS
A B
1) DEAD LOAD OF PANELS ASSUMED TO BE 21 KG.
1129.5 2) WIND LOAD APPLIED AS PER IS 875 : PART III-2015, WITH FOLLOWING CRITERIA
2.1) BASIC 3-S VELOCITY 170 KMPH
2.2) K1=1.05 , TERRAIN : CATEGORY 2 , K3 = K4=1.
2014
991
6
DET- 1
1 2
20 3) GRADE OF ALL STEEL TO BE E250 AS PER IS 2062
991 M1 BRACE
A2
A3 6 ISA35X35X4 ISA35X35X4
79
M2 A1 4) ALL FASTENERS USED TO BE S.S 304
80
8°
ISA35X35X4
ISA35X35X4 ISA35X35X4 1039
231
5) ALL FASTENERS TO HAVE THE STANDERD SET IN S.S. - 1-SPRING WASHER,
400*290 A1 2- NORMAL WASHERS ,1 NUT
ISA35X35X4
+350
592.5
+350 6) CONCRETE USED FOR FOUNDATIONS TO BE M15 GRADE AS PER IS 456 :2000
48.5
438.5
350
400*350 7) MODULE LAYOUT AND ITS TIERS HAVE BEEN FIXED ON ACTUAL LOADING
290
30
30
CONSIDERATIONS PRESCRIBED IN SPECIFICATION AND IS WITH IN THE PRESCRIBED LIMIT.
+0 +0
8) ARRAY LAYOUT TO BE RESTED ON OR ADJACENT RCC BEAMS, WHERE POSSIBLE.
BRICK BAT
RCC ANCHOR BASE-PLATE ANCHOR BASE-PLATE SUPERSTRUCTURE QUANTITIES PER TABLE
STIFFENER
35
25
BASE PLATES
35 75X75X4 0.176 4 0.7065
B1
20
BRACE TYP
4
ISA35X35X4
COLUMN CONNECTION HARDWARE PER TABLE
DETAIL - 1 1:5
1:10 TYP.DETAIL OF BASE PLATE DESCRIPTION DIAMETER
LENGTH/fastener(
NO'S /TABLE
1:10 mm)
MODULE FIXING BOLT
M6/M8 25 8
SS-304
SS304 STEEL BOLTS -
M8 35 8
PURLIN TO COLUMN
A PURLIN
1:5
162.5
1129.5
1 PROJECT
125 KWp Rooftop Solar PV Plant at KBUNL
A CLIENT
B
BLUEARTH ENERGY
B
ADDRESS
38/1997 Vakratunda Soc.,
Gandhinagar, Bandra (E),
Mumbai 400 051
APPROVED :- DESIGN BY :-
DRAWN BY :- CHECKED BY :-
SCALE :- DATE :- 21.12.2020