GROUND FLOOR GIRDER 1 Beam Width = 350 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 400 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 119.886 52.545 123.555 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 360 mm • • RN = Mu = 2.9367 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0076 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 956.98088 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 9 bd 16 mm 5 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 MIDDLE SPAN d = D - Cc = 360 mm • • RN = Mu = 1.2871 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0032 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 426.08696 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 4 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 RIGHT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.0265 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0078 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 988.57698 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 9 bd 16 mm 5 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-2 LOCATION TYPE FRAME GROUND FLOOR GIRDER 2 Beam Width = 350 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 400 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 144.711 56.665 143.112 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.5448 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0093 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1173.9725 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 11 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 MIDDLE SPAN d = D - Cc = 360 mm • • RN = Mu = 1.3880 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0035 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 435.53849 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 4 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 RIGHT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.5056 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0092 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1159.7627 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 11 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-3 LOCATION TYPE FRAME GROUND FLOOR GIRDER 3 Beam Width = 350 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 400 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 135.842 50.967 129.982 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.3275 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0087 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1095.5705 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 10 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 MIDDLE SPAN d = D - Cc = 360 mm • • RN = Mu = 1.2485 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0031 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 426.08696 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 4 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 RIGHT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.1840 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0083 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1044.3121 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 10 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-4 LOCATION TYPE FRAME GROUND FLOOR GIRDER 4 Beam Width = 350 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 450 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 127.02 27.038 135.937 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 410 mm • • RN = Mu = 2.3988 2 - 25 mm øbd² 410 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0061 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 878.21343 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0068414 12 mm 8 bd 16 mm 5 20 mm 3 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 141.0534967 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 MIDDLE SPAN d = D - Cc = 410 mm • • RN = Mu = 0.5106 2 - 25 mm øbd² 410 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0012 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 485.2657 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0068414 12 mm 5 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 141.0534967 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 RIGHT SPAN d = D - Cc = 410 mm • • RN = Mu = 2.5672 2 - 25 mm øbd² 410 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0066 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 943.83001 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0068414 12 mm 9 bd 16 mm 5 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 141.0534967 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-6 LOCATION TYPE FRAME GROUND FLOOR GIRDER 6 Beam Width = 350 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 400 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 136.617 36.872 125.659 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.3465 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0087 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1102.3816 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 10 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 MIDDLE SPAN d = D - Cc = 360 mm • • RN = Mu = 0.9032 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0022 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 426.08696 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 4 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 RIGHT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.0781 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0080 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1006.7681 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 9 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-5 LOCATION TYPE FRAME GROUND FLOOR GIRDER 5 Beam Width = 350 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 400 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 115.413 28.216 144.193 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 360 mm • • RN = Mu = 2.8271 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0073 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 918.67453 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 9 bd 16 mm 5 20 mm 3 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 MIDDLE SPAN d = D - Cc = 360 mm • • RN = Mu = 0.6912 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0017 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 426.08696 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 4 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 RIGHT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.5321 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0093 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1169.3656 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 11 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-7 LOCATION TYPE FRAME GROUND FLOOR GIRDER 7 Beam Width = 350 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 400 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 128.953 37.183 130.647 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.1588 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0082 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1035.3549 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 10 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 MIDDLE SPAN d = D - Cc = 360 mm • • RN = Mu = 0.9108 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0022 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 426.08696 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 4 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 RIGHT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.2002 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0083 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1050.1076 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 10 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-8 LOCATION TYPE FRAME GROUND FLOOR GIRDER 8 Beam Width = 350 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 400 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 119.288 54.163 131.195 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 360 mm • • RN = Mu = 2.9220 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0076 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 951.84616 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 9 bd 16 mm 5 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 MIDDLE SPAN d = D - Cc = 360 mm • • RN = Mu = 1.3267 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0033 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 426.08696 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 4 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 RIGHT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.2137 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0084 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1054.8876 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 10 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-9 LOCATION TYPE FRAME GROUND FLOOR GIRDER 9 Beam Width = 350 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 400 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 119.288 54.163 131.195 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 360 mm • • RN = Mu = 2.9220 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0076 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 951.84616 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 9 bd 16 mm 5 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 MIDDLE SPAN d = D - Cc = 360 mm • • RN = Mu = 1.3267 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0033 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 426.08696 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0077916 12 mm 4 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 48.792743 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 122.763537 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 200 mm Nb - 1 RIGHT SPAN d = D - Cc = 360 mm • • • RN = Mu = 3.2137 3 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0084 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 350 fy Since ρmin < ρ < ρmax ,Therefore use : ρ Then the Beam is Singly Reinforced
As = ρbd = 1054.8876 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 1472.6216 mm² ρ = As = 0.0116875 12 mm 10 bd 16 mm 6 20 mm 4 Since ρ < ρmax ( OK !) 25 mm 3 28 mm 2 a = Asfy = 73.189115 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 3 - 25 mm Mu = 177.4521757 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 80 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-10 LOCATION TYPE FRAME GROUND FLOOR GIRDER 10 Beam Width = 300 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 500 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 0 0 0 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 460 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 460 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 466.66667 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0071141 12 mm 5 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 157.8560943 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 MIDDLE SPAN d = D - Cc = 460 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 460 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 466.66667 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0071141 12 mm 5 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 157.8560943 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 RIGHT SPAN d = D - Cc = 460 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 460 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 466.66667 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0071141 12 mm 5 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 157.8560943 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-11 LOCATION TYPE FRAME GROUND FLOOR GIRDER 11 Beam Width = 300 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 500 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 0 0 0 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 460 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 460 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 466.66667 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0071141 12 mm 5 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 157.8560943 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 MIDDLE SPAN d = D - Cc = 460 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 460 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 466.66667 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0071141 12 mm 5 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 157.8560943 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 RIGHT SPAN d = D - Cc = 460 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 460 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 466.66667 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0071141 12 mm 5 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 157.8560943 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-12 LOCATION TYPE FRAME GROUND FLOOR GIRDER 12 Beam Width = 300 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 500 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 0 0 0 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 460 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 460 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 466.66667 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0071141 12 mm 5 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 157.8560943 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 MIDDLE SPAN d = D - Cc = 460 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 460 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 466.66667 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0071141 12 mm 5 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 157.8560943 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 RIGHT SPAN d = D - Cc = 460 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 460 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 466.66667 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0071141 12 mm 5 bd 16 mm 3 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 157.8560943 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 BEAM DESIGN BEAM NUMBER B-13 LOCATION TYPE FRAME GROUND FLOOR BEAM 13 Beam Width = 300 mm Conc. Str( f'c ) = 28 Mpa MOMENT (kN-m) Beam Height = 400 mm Yield Str. ( fy ) = 414 Mpa LEFT MIDDLE RIGHT Conc. cover = 40 mm Value of β1 = 0.85 mm 0 0 0 Main Bar Size = 25 mm Reduc. Factor = 0.9 mm Tie Bar Size = 10 mm LEFT SPAN d = D - Cc = 360 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 365.21739 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0090903 12 mm 4 bd 16 mm 2 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 121.2761748 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 MIDDLE SPAN d = D - Cc = 360 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 365.21739 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0090903 12 mm 4 bd 16 mm 2 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 121.2761748 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1 RIGHT SPAN d = D - Cc = 360 mm • • RN = Mu = 0.0000 2 - 25 mm øbd² 360 P = 0.85(f'c) fy [ 1 1 2 Rn ] = 0.0000 Bf ' c
fy ( 600 fy ) • • Pmin = 1.4 = 0.0033816 300 fy Since ρ < ρmin < ρmax ,Therefore use : ρmin Then the Beam is Singly Reinforced
As = ρbd = 365.21739 mm² Checking for Actual Moment Capacity:
Diameter #of bars As = 981.7477 mm² ρ = As = 0.0090903 12 mm 4 bd 16 mm 2 20 mm 2 Since ρ < ρmax ( OK !) 25 mm 2 28 mm 2 a = Asfy = 56.924867 mm 32 mm 2 0.85f'cb Therefore use: Mu = [AsFy−( − /2) 2 - 25 mm Mu = 121.2761748 kN-m OK ! Check for Spacing: s = b - 2Cc - (Nb-1)(db) = 150 mm Nb - 1