Schedule of Door Hardware Sets Page 1 of 2

DOCUMENT TITLE : SCHEDULE OF DOOR HARDWARE SETS

DOCUMENT NO : DHQC-CECB-MB-SCH-0-ML-004-B
DOOR HARDWARE IN MASTER SCHEDULE OF HARDWARE FOR SPECIAL DOORS AND SPECIFIC HARDWARE SETS FOR GUIDANCE AND MINIMUM REQUIREMENT ONLY. THE
CONTRACTOR SHALL DESIGN AND INSTALL THE DOOR HARDWARE FOR INTENDED PURPOSE.

UNIT of QUANTITY
SET NUMBER DOOR TYPE ITEM REMARKS
MEASUREMENT PER DOOR

HG-01 EACH 10
HN-06 PAIR 2 1800mm
DC-03 EACH 2
SET A SCR (sound
A DS-01 EACH 2
proof)
SE-02 EACH 1
DB-02 LENGTH QS Acoustic Seals
PS-02 LENGTH QS Acoustic Seals
HG-02 EACH 10
HN-06 PAIR 2 1800mm
SET A2 SCR A2 DC-03 EACH 2
DS-01 EACH 2
SE-02 EACH 1
HG-02 EACH 8
HN-06 PAIR 2 1200mm
DC-03 EACH 2
SE-02 EACH 1
SET B SCR B
DS-01 EACH 2
DB-01 LENGTH QS
IS-01 LENGTH QS
PS-01 LENGTH QS
HG-02 EACH 8
CY-01 EACH 1
ES-01 EACH 1
ML-02 EACH 1
SET B2 B2
HN-06 PAIR 2 1200mm
DC-03 EACH 2
SE-02 EACH 1
BL-2 PAIR 1
DS-01 EACH 2
HG-02 EACH 8
HN-06 PAIR 2 1200mm
SET B2 SCR B2 DC-03 EACH 2
SE-02 EACH 1
DS-01 EACH 2

Defence Headquarters Complex - Akuregoda


Schedule of Door Hardware Sets Page 2 of 2

DOCUMENT TITLE : SCHEDULE OF DOOR HARDWARE SETS

DOCUMENT NO : DHQC-CECB-MB-SCH-0-ML-004-B
DOOR HARDWARE IN MASTER SCHEDULE OF HARDWARE FOR SPECIAL DOORS AND SPECIFIC HARDWARE SETS FOR GUIDANCE AND MINIMUM REQUIREMENT ONLY. THE
CONTRACTOR SHALL DESIGN AND INSTALL THE DOOR HARDWARE FOR INTENDED PURPOSE.

UNIT of QUANTITY
SET NUMBER DOOR TYPE ITEM REMARKS
MEASUREMENT PER DOOR

HG-02 EACH 4
CY-01 EACH 1
ES-01 EACH 1
SET A SCR (sound
SET C A
C ML-02
proof) EACH 1
HN-06 PAIR 2 1000 mm
DC-03 EACH 2
DS-01 EACH 2
HG-02 EACH 4
HN-06 PAIR 2 1000 mm
SET C SCR C
DC-03 EACH 2
DS-01 EACH 2
HG-02 EACH 4
CY-03 EACH 1
ES-01 EACH 1
SET C2 C ML-04 EACH 1
HN-06 PAIR 2 1000 mm
DC-03 EACH 2
DS-01 EACH 2
HG-02 EACH 10
HN-06 PAIR 2 1800mm
DC-03 EACH 2
SE-02 EACH 1
SET E SCR E
DS-01 EACH 2
DB-01 LENGTH QS
IS-01 LENGTH QS
PS-01 LENGTH QS